Clinical Trials Logo

Clinical Trial Summary

In case of instability or rupture of capsular bag occurs during cataract surgery, Yamane technique is one of the options to fix intracocularlens' haptics. Yamane technique uses a double-needle technique that seamlessly fixes the haptics intrascleral by creating a scleral tunnel. Aberrations, IOL tilting or even dislocations might occur and influence the final outcome of IOL implantation. The aim of this study is the evaluation of the postoperative tilt of Kowa PU6AS using Yamane technique. Furthermore of the corrected and uncorrected visual acuity and the anterior chamber depth are being developed.


Clinical Trial Description

During uncomplicated cataract surgery, an intraocular lens (IOL) is implanted into the patient's capsular bag. If increased instability or rupture of this capsular bag occurs due to aggravated intraoperative conditions or IOL dislocation, several options are available to the surgeon to correct the aphakia, all characterized by their respective advantages and disadvantages, but with no clear superiority of any one method. The popular Yamane technique, or "flanged IOL fixation", uses a double-needle technique that seamlessly fixes the haptics intrascleral by creating a scleral tunnel using two 30-gauge needles. Examples of lenses used for this purpose are the TECNIS ZA9003 (Johnson&Johnson, USA) and the Kowa PU6AS (Kowa, Japan). Another approach is the Carlevale FIL-SSF IOL (Soleko, Italy), which was developed specifically for use in aphakia with lack of capsular stability. All types of implantation are not immune to aberrations, tilting or even dislocation. Many factors influence the final outcome of IOL implantation, be it the optimal choice of intraocular lens power, the surgeon's experience regarding fixation in more challenging eyes, or individual anatomical conditions. As part of quality assurance, an evaluation of monthly and six-monthly data will now be performed. The aim of this study is the evaluation of the postoperative tilt of the Kowa PU6AS in Yamane technique, as well as the evaluation of the corrected and uncorrected visual acuity and the anterior chamber depth within the clinical quality management. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05912829
Study type Observational [Patient Registry]
Source Johannes Kepler University of Linz
Contact Christina Silber, MSc
Phone +43 5 7680 83
Email christina.silber@kepleruniklinikum.at
Status Recruiting
Phase
Start date June 1, 2023
Completion date May 2025

See also
  Status Clinical Trial Phase
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A
Terminated NCT00960700 - A Multi Focal Visual Outcome Study Using Different Near Additions N/A
Completed NCT00838045 - Evaluation of the Safety & Effectiveness of the Bausch & Lomb AKREOS® TL Intraocular Lens Phase 4
Completed NCT00773266 - Intraocular Position of Secondary Iris-Fixated IOLs in Aphakic Eyes N/A
Recruiting NCT05796453 - Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix N/A
Completed NCT01230060 - One-Piece Hydrophobic Acrylic Intraocular Lens in Subjects Undergoing Cataract Extraction Phase 3
Completed NCT05481125 - Clareon Toric vs Eyhance Toric N/A
Not yet recruiting NCT04516889 - Evaluating Safety and Efficacy of a Modified Technique of Scleral Fixation Intraocular Lens Implantation N/A
Completed NCT03733730 - Post Approval Study of the AcrySof® IQ ReSTOR® Toric IOLs N/A
Completed NCT04098367 - Clinical Investigation of the AcrySof IQ Vivity Extended Vision Intraocular Lens (IOL) N/A
Completed NCT04528069 - Clinical Investigation of the Visual Outcomes and Safety of a Trifocal Toric IOL in an Asian Population N/A
Completed NCT05852470 - Evaluation of Clareon Vivity/Vivity Toric N/A
Completed NCT01061281 - Evaluation of the Tecnis™ Multifocal and Crystalens™ Accommodating Intraocular Lenses Phase 4
Completed NCT00625313 - Clinical Study of a UV-Absorbing Acrylic Posterior Chamber Intraocular Lens N/A
Completed NCT03316885 - Post-Market Clinical Investigation of the Clareon® IOL N/A
Completed NCT02418871 - Evaluation of the FluidVision Accommodating Intraocular Lens (AIOL) With an Improved Injector System N/A
Completed NCT03054649 - ClarVista HARMONI Toric Trial With Intraoperative Exchange N/A
Not yet recruiting NCT06166901 - Evaluation of Long-term Safety and Performance of PanOptix Intraocular Lens (IOLs) N/A
Withdrawn NCT04800016 - Real-World Study of Vivity Intraocular Lenses (IOLs) N/A
Completed NCT03895034 - Exploratory Study to Evaluate the Use of the RxSight Light Adjustable Lens (LAL) and the Light Delivery Device (LDD) to Improve Visual Outcomes