Aortic Stenosis Clinical Trial
Official title:
A Randomized Trial of PCSK9 Inhibitors in Calcific Aortic Valve Stenosis
Calcific aortic stenosis (CAS) can cause severe adverse cardiac events, but there are currently no effective drugs that can prevent or delay the progression of the disease. In fact, aortic valve replacement remains the only treatment option. CAS has been shown to be associated with Lp(a), LDL-C and PCSK9. Several observational studies indicated that the use of statins to decrease LDL-C levels was associated with the reduced incidence of CAS, but no randomized controlled trials (RCTs) showd that statins had any benefit on the progression of CAS. This may be related to the limited reduction of LDL-C by statin therapy. The proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors have emerged as a new lipid-lowering drug. On the basis of statin therapy, PCSK9 inhibitors can further reduce LDL-C and Lp(a) levels by 50% to 60% and 20% to 30%, respectively. Some studies reported that elevated plasma PCSK9 levels were related to CAS and PCSK9 R46L loss-of-function mutation was associated with lower rates of CAS, and importantly, some observational studies found that PCSK9 inhibitors could reduce the incidence of CAS. Our trial aims to investigate the effect of PCSK9 inhibitors on preventing or delaying the progression of CAS. A total of 160 patients with mild or moderate CAS or asymptomatic severe AS will be randomly assigned to receive either statins or PCSK9 inhibitors+statins. All patients will be followed for at least 2 years at 3, 6,9,12,15,18,21,24 months after randomization. Quality of life (EQ-5D-3L including the EUROQOL visual analogue scale) questionnaires were gathered during each visit. Echocardiography and computer tomography were performed and blood samples were withdrawn at baseline, at 2 years visit, and before withdrawal from the study. The primary endpoint is the average annual change in peak aortic jet velocity on echocardiography. The secondary endpoints include average annual change in aortic valve area on echocardiography, average annual change in aortic valve calcification score on cardiac non-contrast computer tomography, heart valve surgery, change in quality-of-life scores, and average annual change in aortic and coronary artery calcification. Safety endpoints include all-cause death and cardiovascular events. The results of this trial will provide a new idea for the treatment of patients with CAS.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04310046 -
Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial
|
N/A | |
Completed |
NCT03332745 -
Mechanism of Decompensation Evaluation - Aortic Stenosis
|
||
Recruiting |
NCT06008080 -
Post-Market Clinical Follow Up Study With Navitor Valve
|
||
Recruiting |
NCT06055751 -
Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
|
||
Active, not recruiting |
NCT04815785 -
Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis
|
N/A | |
Terminated |
NCT02202434 -
Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement
|
N/A | |
Recruiting |
NCT03029026 -
The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
|
||
Active, not recruiting |
NCT02903420 -
A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan)
|
N/A | |
Completed |
NCT02629328 -
CardioCel Tri-leaflet Repair Study
|
N/A | |
Completed |
NCT02306226 -
Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
|
||
Completed |
NCT01676727 -
ADVANCE Direct Aortic Study
|
||
Withdrawn |
NCT01648309 -
Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation
|
N/A | |
Completed |
NCT01422044 -
Risk Prediction in Aortic Stenosis
|
N/A | |
Withdrawn |
NCT00774657 -
Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography
|
N/A | |
Terminated |
NCT00535899 -
Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS)
|
N/A | |
Terminated |
NCT05070130 -
OpSens PRIME CLASS
|
||
Completed |
NCT03314857 -
China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population
|
N/A | |
Completed |
NCT04157920 -
Impact of Predilatation Between Self-expanding Valves
|
N/A | |
Enrolling by invitation |
NCT06212050 -
Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
|
||
Recruiting |
NCT05893082 -
Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
|
N/A |