Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to observe conduction disturbance, daily activity level, heart rates, oxygen saturation in patients who underwent Transcatheter Aortic Valve Replacement (TAVR) and to evaluate the utility of the HUAWEI Watch (HUAWEI Technologies Co., Ltd., Shenzhen, China) for the potential early warning sign of changes in multiple biometric parameters including heart rate, rhythm, oxygen saturation, activity, and sleep in patients following TAVR. This will be evaluated in the context of a recently implemented early discharge protocol.


Clinical Trial Description

This is a prospective observational cohort study including patients undergoing TAVR procedure in Second Affiliated Hospital of Zhejiang University, School of Medicine. HUAWEI Watch will be assigned to patients within 24 hours before TAVR. HUAWEI Watch GT series can continuously monitor and record multiple biometric parameters heart rate, step counts, sleep cycles and can detect and record the pulse oxygen saturation, as well as analyze QRS complexes and P waves after triggering. The patients will be followed in outpatient clinic visits at 1, 6, 12, 24, and 36 months after TAVR and will commence monitoring with the HUAWEI Watch protocol at least 1 day before the scheduled TAVR procedure to allow familiarity with the device. Patients will be required to activate SMART watch readings (including pulse oxygen saturation and ECG) at least once prior to TAVR and twice per day in the week following TAVR discharge (morning and late afternoon/early evening), at least two days a week for the subsequent month after TAVR discharge and at least once weekly for the remainder of the study. Patients will also be required to activate SMART watch readings at times of any cardiovascular symptoms including dyspnea, chest pain, palpitations, dizziness or presyncope. The health data recorded by HUAWEI Watch will be transmitted to HUAWEI phone application. The Heart Health App (developed by Second Affiliated Hospital, School of Medicine, Zhejiang University) will receive, process and store the data, and transfer it to remote database after approval by patients. A designated heart team member would access the data via a cloud database, contact the patient further investigation or management was deemed necessary. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04454177
Study type Observational
Source Second Affiliated Hospital, School of Medicine, Zhejiang University
Contact Jiaqi Fan, MD
Phone +86-15267029492
Email fanjiaqi@zju.edu.cn
Status Recruiting
Phase
Start date July 15, 2020
Completion date July 1, 2031

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Completed NCT03332745 - Mechanism of Decompensation Evaluation - Aortic Stenosis
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A