Clinical Trials Logo

Clinical Trial Summary

To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR).


Clinical Trial Description

Trial Objectives: To assess the safety and feasibility of Transcatheter Aortic Valve Replacement (TAVR) with commercially available bioprostheses in patients with severe, symptomatic aortic stenosis (AS) who are low-risk (STS score ≤3%) for surgical aortic valve replacement (SAVR). Methodology: This is a multicenter, prospective trial of TAVR in low-risk patients at up to twelve sites in the United States. The trial will have three arms. The first will comprise 200 patients undergoing transfemoral TAVR. The second arm will comprise200 closely matched historical controls who underwent isolated bioprosthetic SAVR. Historical controls will be selected from among patients at the same site who have undergone isolated bioprosthetic SAVR within the previous 36 months. TAVR patients will then be matched to SAVR patients using STS database variables to perform propensity matching, including (but not limited to) age, gender, race, ethnicity, STS score, and valve prosthesis size. Once the historical matched controls are identified, detailed chart review will abstract in-hospital and 30-day outcomes for the SAVR cohort. The third arm of the trial will comprise a registry of TAVR in up to 100 low-risk patients with bicuspid aortic valve. The results from the registry arm will be analyzed independently. Primary Efficacy Endpoint: All-cause mortality at 30 days following transfemoral TAVR vs. bioprosthetic SAVR. Primary Safety Endpoint: Defined as the composite of major adverse events at 30 days: a. all-cause mortality c. spontaneous myocardial infarction (MI) d. reintervention: defined as any cardiac surgery or percutaneous reintervention that repairs, alters, or replaces a previously implanted aortic valve e. VARC life-threatening bleeding f. Increase in serum creatinine to ≥300% (>3x increase compared to baseline) OR serum creatinine ≥4.0 mg/dL with an acute increase ≥0.5 mg/dL OR new requirement for dialysis g. coronary artery obstruction requiring percutaneous or surgical intervention h. VARC major vascular complication i. cardiac tamponade j. cardiac perforation k. pericarditis l. mediastinitis m. hemolysis n. infective endocarditis o. moderate or severe aortic insufficiency p. significant aortic stenosis q. permanent pacemaker implantation r. new-onset atrial fibrillation Secondary Endpoints (TAVR Cohort): 1. Major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days, 6 months, 12 months, and 2, 3, 4 and 5 years, defined as the composite of: 1. all-cause mortality 2. stroke 3. spontaneous MI 4. reintervention 2. The occurrence of the individual components of MACCE at 30 days, 6 months, 12 months, and 2, 3, 4, and 5 years (including stoke). 3. The composite of major adverse device events post-procedure, and at 6 months, 1 year, and 2, 3, 4, 5 years 4. VARC major vascular complications, at 30 days and 1 year 5. VARC life-threatening or disabling bleeding, at 30 days and 1 year 6. Technical success upon exit from the operating room or catheterization laboratory, defined as all of the following: 1. alive 2. successful access, delivery, and retrieval of the device and/or delivery system 3. correct positioning and successful deployment of the valve 4. no need for unplanned or emergency surgery or reintervention related to the device or access procedure, including reinstitution of cardiopulmonary bypass post-weaning for SAVR patients 7. Device success at 30 days and 1 year, defined as all of the following: 1. absence of procedural mortality 2. correct positioning of a single prosthetic heart valve in the proper anatomical location 3. device performing as intended: 1. No migration, erosion, embolization, detachment, fracture, hemolysis requiring transfusion, thrombosis, or endocarditis 2. Intended performance of the heart valve: no prosthesis-patient mismatch, mean aortic valve gradient <20 mm Hg OR peak velocity <3 m/s, AND no moderate or severe bioprosthetic valve regurgitation 8. Procedural success at 30 days, defined as device success AND no major adverse device events 9. Bioprosthetic valve regurgitation, defined as either moderate or severe aortic regurgitation OR moderate or severe paravalvular leak, at hospital discharge, 12 months, and 2, 3, 4, and 5 years 10. Incidence of new-onset atrial fibrillation at hospital discharge, and at 30 days, 12 months, and 2, 3, 4, and 5 years. 11. Conduction disturbance requiring permanent pacemaker implantation at hospital discharge, 12 months, and 2, 3, 4, and 5 years. 12. Change in NYHA class from baseline to 30 days, baseline to 6 months, baseline to 12 months, and baseline to 2-5 years. 13. Change in distance walked during 6-minute walk test from baseline to 12 months. 14. Change in responses to the short form Kansas City Cardiomyopathy Questionnaire (KCCQ-12) from baseline to 12 months. 15. Echocardiographic assessment of the bioprosthetic valve post-procedure, at 12 months, and at years 2-5, including (but not limited to): a. aortic valve mean gradient, maximum gradient, and peak velocity b. calculated aortic valve area c. degree of bioprosthetic valve regurgitation 16. Assessment for subclinical leaflet thrombosis with multislice computed tomography, or transesophageal echocardiography if GFR <50 mL/min/m2, at 1 to 2 months. 17. Individual patient level Success all of the following and device success: 1. No re-hospitalizations or re-interventions for the underlying condition (e.g., HF) 2. Return to prior living arrangement (or equivalent) 3. Improvement vs. baseline in symptoms (NYHA Class decrease ≥ 1) 4. Improvement vs. baseline in functional status (6MWT increase ≥ 50 meters) 5. Improvement vs. baseline in QoL (KCCQ increase ≥ 10) Number of Trial Sites: 12 Sample Size: 200 consecutive patients and 200 historical controls, and an additional 100 (up to) patients with bicuspid aortic valve Patient Population: Patients with severe, symptomatic AS who are determined by the Heart Team to be at low surgical risk (STS score ≤3%). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02628899
Study type Interventional
Source Medstar Health Research Institute
Contact
Status Completed
Phase N/A
Start date January 2016
Completion date January 2023

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Completed NCT03332745 - Mechanism of Decompensation Evaluation - Aortic Stenosis
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Completed NCT01676727 - ADVANCE Direct Aortic Study
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A