Aortic Stenosis Clinical Trial
Official title:
Use of the Self-Expanding Medtronic CoreValve Prosthesis Without Predilation in Patients With Severely IMPaired Left-VentrIcular Ejection Fraction for TAVI Trial - The SIMPLIFy TAVI Trial
The purpose of this study is to demonstrate that the avoidance of balloon valvuloplasty for predilation of the native aortic valve is associated with a reduction of the composite primary endpoint in TAVI patients with severely impaired left-ventricular ejection fraction (LVEF ≤35%).
Transcatheter aortic valve implantation (TAVI) has evolved as an alternative to surgical aortic valve replacement (SAVR) with now more than 50,000 implantations in patients with symptomatic severe aortic stenosis, who were considered to be at very high or prohibitive operative risk. Before deployment of transcatheter heart valves (THV), current medical practice requires right-ventricular rapid burst pacing (>180 bpm) with induction of a functional cardiac arrest for up to 30 seconds for balloon aortic valvuloplasty (BAV). This step is thought to be necessary to predilate the native aortic valve and to facilitate an accurate positioning of the THV. However, BAV has been shown to have numerous detrimental effects: i) the functional cardiac arrest induced by rapid pacing for BAV leads to transient coronary, cerebral, and renal ischemia. ii) In patients with impaired left ventricular ejection fraction, prolonged cardiac depression after rapid pacing is observed and may result in hemodynamic failure and systemic inflammatory response syndrome (SIRS), which are both associated with a high peri-procedural mortality. iii) BAV has been identified as a major source of embolization of thrombotic and valvular material and increases the risk for coronary obstruction with subsequent myocardial infarction and stroke. iv) the local trauma in the left-ventricular outflow tract caused by BAV contributes to conduction disturbances with the need for permanent pacemaker implantation after TAVI. A non-randomized pilot study by Grube et al. (JACC Interventions 2011) has recently shown that TAVI without BAV is feasible and safe, since self-expanding THV are able to "dilate" the stenosed aortic valve through the radial forces of the self-expanding nitinol frame, in which the prosthesis is mounted. According to the mentioned study, omitting BAV allows the delivery of the THV in a controlled fashion without hemodynamic compromise of the patient. Patients with LVEF≤35% will be randomized (like the flip of a coin) to TAVI without BAV (experimental group) or TAVI with BAV for predilation (control group). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04310046 -
Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial
|
N/A | |
Completed |
NCT03332745 -
Mechanism of Decompensation Evaluation - Aortic Stenosis
|
||
Recruiting |
NCT06008080 -
Post-Market Clinical Follow Up Study With Navitor Valve
|
||
Recruiting |
NCT06055751 -
Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
|
||
Active, not recruiting |
NCT04815785 -
Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis
|
N/A | |
Terminated |
NCT02202434 -
Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement
|
N/A | |
Recruiting |
NCT03029026 -
The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
|
||
Active, not recruiting |
NCT02903420 -
A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan)
|
N/A | |
Completed |
NCT02629328 -
CardioCel Tri-leaflet Repair Study
|
N/A | |
Completed |
NCT02306226 -
Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
|
||
Withdrawn |
NCT01648309 -
Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation
|
N/A | |
Completed |
NCT01676727 -
ADVANCE Direct Aortic Study
|
||
Completed |
NCT01422044 -
Risk Prediction in Aortic Stenosis
|
N/A | |
Withdrawn |
NCT00774657 -
Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography
|
N/A | |
Terminated |
NCT00535899 -
Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS)
|
N/A | |
Terminated |
NCT05070130 -
OpSens PRIME CLASS
|
||
Completed |
NCT03314857 -
China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population
|
N/A | |
Completed |
NCT04157920 -
Impact of Predilatation Between Self-expanding Valves
|
N/A | |
Enrolling by invitation |
NCT06212050 -
Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
|
||
Recruiting |
NCT05893082 -
Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
|
N/A |