Aortic disease is a life-threatening condition requires swift surgery or intervention. With modern techniques and vascular prostheses, still quite a few patients suffer surgery/intervention related complications such as suture line pseudoaneurysm, stent- induced re-entry tear, and aneurysmal expansion. Previous studies suggest that these complications may be related to the abnormal aortic motion pattern and biomechanical stress induced by vascular prostheses. The relationship between aortic motion changes and aortic adverse events after treatment still remains unclear. A dynamic protocol (multiphase contrast-enhanced ECG-gated) CT scan is able to measure the spatial motion of the ascending aorta, and finite element modelling is able to simulate both surgery or endovascular intervention and analyse the biomechanical interaction between vascular prostheses and tissue based on the patient-specific images. This project is aiming to explore and identify the interaction of 4D aortic motion and the biomechanical changes after surgery or endovascular treatment.


Clinical Trial Description

Overall design The study population will consist of patients to be examined for proximal aortic conditions (dissection or aneurysm) requiring surgery or endovascular intervention. A patient cohort will be recruited to explore the effects of surgical or endovascular prosthesis on the adjacent aorta, and its impact on late clinical outcomes. Patient recruitment Patients who have proximal aortic conditions and are referred to the aortic team in Royal Brompton and Harefield Hospitals will be screened for eligibility. For this pilot study and in view of the volume of aortic surgery in the Trust (approx. 100 cases per year), 30 patients will be recruited in the first year of this project to be followed for at least one year for clinical outcomes. Imaging protocol After obtaining written informed consent, a new dynamic (multiphase ECG-gated contrast- enhanced) CT imaging protocol will be used for participants to replace the standard (ECG- gated contrast-enhanced) CT protocol both prior to and after surgical or endovascular intervention. The therapeutic pathway and clinical decision making will not be affected by the new imaging protocol. Study participants will receive the same standard of treatment and care as well as follow up surveillance as all other patients not participating in this study. The same dynamic CT image protocol will be offered prior to hospital discharge. Image processing and motion analysis Image processing and analysis will be performed offline, and thus not affect the clinical pathway or delay standard treatment. Dynamic images will be extracted from the Trust PACS. Suitable sets of images will be anonymized, reconstructed using a Trust approved software and downloaded to a protected area on a Trust server for offline analysis. The analysis of 4D motion of the aortic root will be conducted using image processing software authorised by the Trust (3D Slicer). Detailed analysis requires the identification of end- systolic and end-diastolic frames, followed by measurements in 6 degrees of freedom (3 directions of displacement and 3 axial rotations in a global coordinate system). The raw motion data will be transferred to a patient-specific anatomical coordinate system (identified by the individual sinotubular junction) for further statistics with Matlab (Mathworks, USA). Finite element modelling The spatial patient-specific model will be reconstructed from CT image and then automatically meshed for further simulation. The finite element analysis will be performed by using a commercial structural mechanics solver (Abaqus; Dassault Systèmes, France). The 4D motion data will be applied as the boundary condition to describe the motion of the ascending aorta in the model. The pulsatile pressure load from the blood flow will be applied to the inner surface of the model. Virtual surgery or endovascular intervention simulation will then be performed on this model to determine key biomechanical parameters, such as principal stresses and shear strain, which later will be correlated to clinical adverse events during follow-up. The results will allow us to elucidate the role of biomechanical changes in clinical events after surgery/intervention and to identify which parameter might predict adverse outcome in these patients. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04958083
Study type Interventional
Source Royal Brompton & Harefield NHS Foundation Trust
Contact Christoph Nienaber, MD, PhD
Phone +4402073528121
Email c.nienaber@rbht.nhs.uk
Status Not yet recruiting
Phase N/A
Start date August 2021
Completion date June 2023

See also
  Status Clinical Trial Phase
Completed NCT05582967 - The DAShED (Diagnosis of Aortic Syndrome in the ED) Study
Terminated NCT04116684 - Digital Home Blood Pressure Monitoring in Type B Aortic Dissection Patients N/A
Completed NCT02086136 - Aortic Dissection Detection Risk Score Plus D-dimer in Suspected Acute Aortic Dissection
Recruiting NCT02201589 - Feasibility of Endovascular Repair Of Ascending Aortic Pathologies N/A
Recruiting NCT03948555 - Magnetic Resonance Imaging (MRI) for Aortic Dissection to Visualise Inflammation
Enrolling by invitation NCT05912608 - Optimal Strategy for Repair of Type A Acute Aortic Dissection
Recruiting NCT03707743 - Registry of Patients With Acute/Subacute Type B Aortic Dissection Treated by Means of the STABILISE Technique (STABILISE)
Enrolling by invitation NCT00583817 - Endovascular Treatment of Thoracic Aortic Disease N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT02523300 - Glucocorticoid on the Prognosis of TEVAR N/A
Completed NCT01197651 - Aortic-Stent-Register N/A
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Not yet recruiting NCT06044259 - Study Comparing Hemiarch Replacement and Hemiarch Plus Stent Implantation in Acute Aortic Dissection N/A
Completed NCT05039814 - Prediction of Postoperative Acute Kidney Injury in Patients With Acute Type A Aortic Dissection Using Cystatin C
Recruiting NCT03780738 - A Validation Study of The Relationship Between ALDH2 and Aortic Dissection
Completed NCT03647566 - 18F Sodium Fluoride PET/CT in Acute Aortic Syndrome
Enrolling by invitation NCT05800743 - Evaluation of the GORE® Ascending Stent Graft N/A
Recruiting NCT03347812 - Clinical Study for Evaluating the Safety and Efficacy of Total Endovascular Aortic Arch Repair N/A
Completed NCT05044494 - Surgery for Delay-recognized or Defer-operated Type A Aortic Dissection
Terminated NCT02958098 - My Research Legacy Pilot Study