Clinical Trials Logo

Clinical Trial Summary

Aortic dissection is a life-threatening condition caused by a tear in the internal layer of major artery wall (aorta) that carries blood to all body organs, resulting in separation of the aortic wall layers (dissection). The dissected aorta compromises blood flow to any organ, and eventually leads to organ damage (Malperfusion Syndrome). Our goal in this project is to use Intravascular Ultrasound (IVUS) to have real time assessment and confirm any evidence of malperfusion syndrome in the setting of aortic dissection after repairing the original aortic tear. IVUS is a small ultrasound (sound waves) wand that is attached to the top of a thin tube. This tube is inserted into the aorta from the groin. This device takes pictures of the aorta and its major branches, to identify problems with blood flow. Having this real-time and dynamic assessment will help to identify any malperfused organs before leaving the operating room and allow us to address the malperfusion syndrome as quickly as possible to limit complications. Without this technique, identifying the problem can take several days after surgery at which point there can be irreversible complications.


Clinical Trial Description

Acute Type A Aortic Dissection A Debakey acute type A aortic dissection (ATAAD) represents a lethal condition with a risk of mortality of 1% per hour and up to nearly 50% in first 48 hours if left untreated.1, 2 Traditional surgical teaching has always involved emergent repair of the proximal aortic with resection and replacement of the intima entry tear and aneurysmal tissue within the ascending aorta. This approach addresses obviates the risk of aortic rupture, proximal extension into the coronary arteries, cardiac tamponade and aortic valve insufficiency, all of which lead to mortality. However, as expertise in the field progress evidence is emerging that dealing with only the proximal extent of the dissection may still leave a significant portion of patients at risk for complications from an inability to identify and treat end-organ malperfusion.3 At Western University and London Health Sciences center our mortality rate for patients presenting the ATAAD has been reporter at 20.0%4, and is similar to that reported by the International Registry of Acute aortic Dissection (IRAD) database, with mortality rates between 16.2 and 27.4%.5,6 Malperfusion Syndrome and Aortic Rupture In the 2018 Circulation paper published by Yang et al. the University of Michigan group outline the treatment strategy for ATAAD. In this study, all patients with an ATAAD presenting with malperfusion, but without signs of aortic rupture or cardiac tamponade, were treated first with endovascular revascularization followed by delayed open aortic repair.3 The authors report that in the second decade of their experience with this treatment model, the overall mortality dropped to 10.7%.3 When compared to our local data and that published by the IRAD group, it would appear that there are significant improvements that can be made for the treatment of these individuals. The authors report that roughly 1/3 of all patients presented with some form of malperfusion syndrome and that in this group, 87% of the deaths were attributed to organ failure from malperfusion even after fenestration and stenting. Conversely there was only a 4% risk of aortic rupture following fenestration and stenting prior to open surgical repair in this group.3 This would indicate that malperfusion is a significant cause of morbidity and mortality in these patients maybe even more so than the risk of aortic rupture in selective patients but in order to improve our outcomes, we need a better way to assess static and dynamic changes that cause malperfusion as early as possible. Static and Dynamic Arterial Malperfusion The concept of static and dynamic obstructions in regards to aortic blood flow, indicates the phenomenon where disruption of laminar flow due to interruption of the intimal layer in and aortic dissection, results in gradients between the true and false lumen which can shear a dissection flap over a branching vessel causing collapse of the true lumen (dynamic), or the development of thrombus within the false lumen resulting in obstruction of a branch vessel (static). Most emergent AAD repairs will involve a baseline CT scan of the chest, abdomen and pelvis, which may identify malperfusion of distal arteries shown by a lack of contrast opacification. However, this is done prior to surgical repair and not an accurate representation of perfusion after proximal surgical repair is completed. Frist of all, at the time of the initial CT scan the intimal tear is still present and flow may not be directed into the true lumen, patients blood pressures may not be controlled which can cause dynamic shifts in the intimal flap favouring either true or false lumen flow, and lastly multiple distal re-entry tears can form throughout the remaining aorta after surgical repair which also have the capability of altering arterial flow. Transesophageal echocardiogram is usually present at the time of open surgical repair, but it is limited to the ascending, arch and descending thoracic aorta and provides little information regarding flow to the visceral segments, kidneys and legs. Intravascular Ultrasound (IVUS) Intravascular Ultrasound (IVUS) has been used over the past several decades for the real-time assessment of vascular anatomy in a variety of clinical settings.7 Standard IVUS catheters typically use a 9-French delivery sheath and are run over a 0.035-inch guidewire. The device transducer emits and receives signals at varying frequencies to produce a 360ĚŠ axial image. As surgeons are becoming more familiar with this technology and developing the skill set necessary to use the equipment, including the real-time acquisition and interpretation of images, it permits the full evaluation of the thoracoabdominal aorta including size, tortuosity, and calcification. In the setting of an AAD, IVUS can provide real-time data under physiologic conditions following open proximal repair to indicate the presence of distal re-entry tears, compression of the true lumen and malperfusion to aortic branches. It also, can be used intraoperatively to confirm resolution of malperfusion to the visceral segments and legs after proximal flow is reinsituted into the true lumen. Study Rationale As noted above, AAD is a lethal condition that every cardiovascular surgeon is faced with at some point in their career. Although the outcomes at LHSC have been historically very good and are on par with or better than the existing IRAD data, looking at other institutions who have more advanced approaches, there appears to be some room to improve our outcomes even further. We believe that emergent repair of the proximal extent of the AAD, which is the current standard at LHSC, results in stabilization of the aortic valve, protects coronary flow, relieves cardiac tamponade and reduces the risk of aortic rupture. However, this approach leaves patients at risk for distal malperfusion due to distal re-entry tears, patent false lumens and thrombus formation, creating both dynamic and static obstruction. Intraoperative IVUS evaluation would therefore allow for the assessment of distal perfusion immediately following proximal repair in order to identify malperfusion and adjust treatment accordingly to prevent damage from prolonged end-organ ischemia. The purpose of this study is to test the safety and efficacy of intraoperative IVUS immediately following open surgical repair. Device Description The study devices are intended to improve outcomes for patients presenting with malperfusion syndrome in the setting of ATAAD. Every subject in the cohort must be deemed treatable with an 8Fr IVUS from an anatomy and clinical safety perspective. Intravascular ultrasound 0.035 PV catheter system The investigational 0.035 PV IVUS catheter (Volcano Therapeutics, Rancho Cordova, CA) is an over the wire catheter-based ultrasound with an 8.2-French profile at the transducer end and 7.0-French shaft diameter. This is run through a 9-French place under surface ultrasound guidance in the common femoral artery. The working length of this catheter is 90 cm, with the ability to imaging a diameter up to 60 mm.7 ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04907071
Study type Interventional
Source London Health Sciences Centre
Contact Karama Bayamin, MD
Phone 15196858500
Email Karama.Bayamin@lhsc.on.ca
Status Not yet recruiting
Phase N/A
Start date March 1, 2022
Completion date August 1, 2023

See also
  Status Clinical Trial Phase
Completed NCT05582967 - The DAShED (Diagnosis of Aortic Syndrome in the ED) Study
Terminated NCT04116684 - Digital Home Blood Pressure Monitoring in Type B Aortic Dissection Patients N/A
Completed NCT02086136 - Aortic Dissection Detection Risk Score Plus D-dimer in Suspected Acute Aortic Dissection
Recruiting NCT02201589 - Feasibility of Endovascular Repair Of Ascending Aortic Pathologies N/A
Recruiting NCT03948555 - Magnetic Resonance Imaging (MRI) for Aortic Dissection to Visualise Inflammation
Enrolling by invitation NCT05912608 - Optimal Strategy for Repair of Type A Acute Aortic Dissection
Recruiting NCT03707743 - Registry of Patients With Acute/Subacute Type B Aortic Dissection Treated by Means of the STABILISE Technique (STABILISE)
Enrolling by invitation NCT00583817 - Endovascular Treatment of Thoracic Aortic Disease N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT02523300 - Glucocorticoid on the Prognosis of TEVAR N/A
Completed NCT01197651 - Aortic-Stent-Register N/A
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Not yet recruiting NCT06044259 - Study Comparing Hemiarch Replacement and Hemiarch Plus Stent Implantation in Acute Aortic Dissection N/A
Completed NCT05039814 - Prediction of Postoperative Acute Kidney Injury in Patients With Acute Type A Aortic Dissection Using Cystatin C
Recruiting NCT03780738 - A Validation Study of The Relationship Between ALDH2 and Aortic Dissection
Completed NCT03647566 - 18F Sodium Fluoride PET/CT in Acute Aortic Syndrome
Enrolling by invitation NCT05800743 - Evaluation of the GORE® Ascending Stent Graft N/A
Recruiting NCT03347812 - Clinical Study for Evaluating the Safety and Efficacy of Total Endovascular Aortic Arch Repair N/A
Completed NCT05044494 - Surgery for Delay-recognized or Defer-operated Type A Aortic Dissection
Terminated NCT02958098 - My Research Legacy Pilot Study