Clinical Trials Logo

Clinical Trial Summary

The Freestyle® prosthesis (Medtronic plc, Dublin, Ireland) is a biological, porcine aortic root implanted in various combinations and techniques since the 1990s. The main indication for the choice of this prosthesis is a combined pathology with degenerated aortic valve and additional dilatation of the root often involving the ascending aorta.

The Freestyle® prosthesis is also used in cases of dissection of the ascending aorta with the involvement of the aortic valve, which opens the debate on how far the ascending aorta should be replaced for a sustainable solution with calculable low periprocedural risk. Considering a lower intraoperative risk in the life-threatening situation, an extended resection of the aorta can be avoided and only the aortic root replaced with a piece of ascending aorta. On the contrary, focusing on improved long-term outcome, the technique of total arch replacement in aortic dissection was developed in emergency situations with acceptable results, which, however, were often reproducible only in large, experienced centers.

Apart from the abovementioned options, the technique of proximal arch replacement can provide a tension-free anastomosis. The intention of hemiarch replacement is the attachment of the prosthesis to an aneurysm-free portion of the aortic arch helping to protect against further anastomotic aneurysms and spare the patient complex reoperation or interventional procedures in the future. As a possible drawback of the technique, especially in emergency situations, the potentially prolonged duration of surgery and the need of selective brain perfusion via axillary or carotid artery are discussed increasing the risk of stroke and further major events, which could not be reflected in current literature. However, there is still no convincing evidence of a long-term benefit in terms of re-operation and survival after hemiarch replacement.

The aim of this retrospective analysis was to assess the mid-term outcome of the biological Freestyle® prosthesis in combination with operations on the ascending aorta and the aortic arch with regard to prosthetic performance, reoperations, stroke and death.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04068337
Study type Observational
Source Triemli Hospital
Contact
Status Completed
Phase
Start date August 1, 2018
Completion date August 1, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Enrolling by invitation NCT04035356 - HAART Annuloplasty Device Valve Repair Registry
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Completed NCT02283307 - Dual Energy CT Urography With Reduced Iodinated Contrast N/A
Completed NCT01678261 - X-chromosome Inactivation, Epigenetics and the Transcriptome N/A
Terminated NCT01055275 - Cook Iliac Branch Graft Post-market Registry N/A
Completed NCT00615888 - Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair N/A
Completed NCT03510793 - Microcirculation and Anesthesia in Vascular Surgery
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT01918969 - Reference Values of Circulating Endothelial Progenitor Cells N/A
Not yet recruiting NCT01918982 - Circulating Endothelial Progenitor Cells and Aortic Aneurysm N/A
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT01256372 - An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery Phase 2
Recruiting NCT00661518 - PET/CT Imaging of Aneurysm Wall Inflammation N/A
Completed NCT00094575 - Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA) Phase 4
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Recruiting NCT05603520 - Phenotyping Heterogeneity and Regionality of the Aorta
Completed NCT03727542 - Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels N/A