Administrative data

NCT number NCT00802984
Other study ID # SU-11092007-868
Secondary ID IRB Protocol Num
Status Completed
Phase Phase 4
First received
Last updated
Start date January 2002
Est. completion date December 2005

Study information

Verified date October 2020
Source Stanford University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to determine whether the system is safe and effective for the intended use of treating descending thoracic aortic aneurysms.


Recruitment information / eligibility

Status Completed
Enrollment 29
Est. completion date December 2005
Est. primary completion date December 2005
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

1. Patient is a candidate for repair of a descending thoracic aortic aneurysm.

2. Patient has one or more of the following:

- Descending thoracic aneurysm, 5 cm in diameter or greater with proximal and distal neck suitable for stent graft placement.

- Aneurysm is 4-5 cm in diameter but has increased in size by 0.5 cm in last 6 months.

- Maximum diameter of aneurysm exceeds one and one-half times the transverse dimension of an adjacent normal aortic segment.

- Post-traumatic pseudoaneurysm

- Post-surgical pseudoaneurysm

- Saccular aneurysm

- Contained rupture

- Penetrating ulcer

3. Patient's vascular dimensions must be in the range that can be safely treated with the stent graft and extensions available to the physician at the time of the procedure.

4. Patient has patent iliac or femoral arteries or acceptable retroperitoneal access via the abdominal aorta that allow endovascular access to the aneurysmal site with a 23F delivery catheter, typically used with a 25F introducer sheath

5. Patient has a non-aneurysmal proximal and distal aortic neck diameter between 25 and 36 mm.

6. Patient is American Society of Anesthesiology (ASA) grade 1 through 4.

7. Patient has a stage of disease or condition where there is no comparable or satisfactory alternative device or therapy available for treatment; or the patient has an immediately life-threatening disease in which there is a reasonable likelihood that death will occur within a matter of months or in which premature death is likely without early treatment.

8. Patient is able and willing to comply with 1 month, 6 month, and 1 year follow-up, and willing to comply with annual post-treatment follow-up requirements thereafter.

9. Patient or patient's legal representative understands and has signed an Informed Consent.

Exclusion Criteria:

1. The stent graft would have to be positioned such that there would be no flow to an artery, major branch artery or major branch arteries which supply the spinal cord.

2. The patient has congenital abnormalities in which the placement of the stent graft will cause occlusion of major arterial flow. Such abnormalities should be evaluated prior to treatment.

3. Patient is pregnant.

4. Patient is morbidly obese or has other clinical conditions that severely inhibit X-ray visualization of the aorta.

5. Patient has connective tissue disease.

6. Patient has a hypercoagulability disorder.

7. Patient is in acute renal failure.

8. Patient has active systemic infection.

9. Patient is less than 18 years old.

10. Patient has less than a one-year life expectancy.

11. Patient is participating in another research study involving an investigational agent for the treatment of Descending Thoracic Aortic Aneurysms.

12. Patient has other medical, social or psychological issues that in the opinion of the investigator preclude them from receiving this treatment, and the procedures and evaluations pre- and post-treatment.

13. Patient is unwilling or unable to return for or comply with follow-up visit schedules.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Endovascular thoracic aortic aneurysm repair using TALENT TAA Stent Graft System


Locations

Country Name City State
United States Stanford University School of Medicine Stanford California

Sponsors (1)

Lead Sponsor Collaborator
Stanford University

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Stent graft migration
Primary Vessel Dissection or perforation
Primary Stent graft occlusion
Primary Collateral vessel occlusion
Primary Aneurysm rupture
Primary Aneurysm exclusion
Secondary Technical success
Secondary Patency
See also
  Status Clinical Trial Phase
Active, not recruiting NCT02777593 - Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2 N/A
Completed NCT02876263 - Noninvasive Neuromonitoring of Surgery of the Thoracic Aorta N/A
Terminated NCT02538822 - Risk of Rupture of Aneurysms of the Thoracic Ascending Aorta (ATA) From the Dynamic Imaging N/A
Completed NCT04930172 - TOtal tRansfemoral branCHed endovasCular tHoracoabdominal Aortic Repair Registry
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT03010514 - A Registry Study on Genetics and Biomarkers of Thoracic Aortic Aneurysm/Dissection N/A
Completed NCT02266342 - GORE® TAG® Thoracic Endoprosthesis French Mandatory Registry
Completed NCT00757003 - To Evaluate the Safety and Efficacy for GORE TAG Thoracic Endoprosthesis in the Treatment of Thoracic Aortic Disease Phase 3
Recruiting NCT03574311 - Preoperative Intravenous Ferric Carboxymaltose and Placebo in the Treatment of Patients Undergoing Cardiac Surgery Phase 4
Suspended NCT03410420 - Detection of Hypoxia in Human Thoracic Aorta Using Pimonidazole Hydrochloride Phase 1
Recruiting NCT05703893 - Investigation of the Neurovegetative Pattern in Patients With Thoracic Aortic Aneurysms (TAA)
Enrolling by invitation NCT05800743 - Evaluation of the GORE® Ascending Stent Graft N/A
Completed NCT02253082 - Vasculopathic Injury and Plasma as Endothelial Rescue - OCTAplas Trial (EudraCT no. 2014-000452-28) Phase 4
Recruiting NCT02323581 - Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts N/A
Active, not recruiting NCT03414866 - Thoraflex Hybrid Post-Market Study
Recruiting NCT01985906 - Safety and Efficacy of Multiple Overlapping Uncovered Stents for Pararenal Aortic Aneurysm Repair N/A
Active, not recruiting NCT02818972 - RelayPro Thoracic Stent-Graft in Subjects With Thoracic Aortic Aneurysms and Penetrating Atherosclerotic Ulcers N/A
Completed NCT03479164 - Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms N/A
Completed NCT01775046 - Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
Recruiting NCT04814238 - Minimally Invasive Aortic Root and Aorta surGery rEgistry