Aortic Aneurysm, Thoracic Clinical Trial
Official title:
Endovascular Treatment of Thoracic Aortic Aneurysms Using the TALENT Stent Graft System
Verified date | October 2020 |
Source | Stanford University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of this study is to determine whether the system is safe and effective for the intended use of treating descending thoracic aortic aneurysms.
Status | Completed |
Enrollment | 29 |
Est. completion date | December 2005 |
Est. primary completion date | December 2005 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: 1. Patient is a candidate for repair of a descending thoracic aortic aneurysm. 2. Patient has one or more of the following: - Descending thoracic aneurysm, 5 cm in diameter or greater with proximal and distal neck suitable for stent graft placement. - Aneurysm is 4-5 cm in diameter but has increased in size by 0.5 cm in last 6 months. - Maximum diameter of aneurysm exceeds one and one-half times the transverse dimension of an adjacent normal aortic segment. - Post-traumatic pseudoaneurysm - Post-surgical pseudoaneurysm - Saccular aneurysm - Contained rupture - Penetrating ulcer 3. Patient's vascular dimensions must be in the range that can be safely treated with the stent graft and extensions available to the physician at the time of the procedure. 4. Patient has patent iliac or femoral arteries or acceptable retroperitoneal access via the abdominal aorta that allow endovascular access to the aneurysmal site with a 23F delivery catheter, typically used with a 25F introducer sheath 5. Patient has a non-aneurysmal proximal and distal aortic neck diameter between 25 and 36 mm. 6. Patient is American Society of Anesthesiology (ASA) grade 1 through 4. 7. Patient has a stage of disease or condition where there is no comparable or satisfactory alternative device or therapy available for treatment; or the patient has an immediately life-threatening disease in which there is a reasonable likelihood that death will occur within a matter of months or in which premature death is likely without early treatment. 8. Patient is able and willing to comply with 1 month, 6 month, and 1 year follow-up, and willing to comply with annual post-treatment follow-up requirements thereafter. 9. Patient or patient's legal representative understands and has signed an Informed Consent. Exclusion Criteria: 1. The stent graft would have to be positioned such that there would be no flow to an artery, major branch artery or major branch arteries which supply the spinal cord. 2. The patient has congenital abnormalities in which the placement of the stent graft will cause occlusion of major arterial flow. Such abnormalities should be evaluated prior to treatment. 3. Patient is pregnant. 4. Patient is morbidly obese or has other clinical conditions that severely inhibit X-ray visualization of the aorta. 5. Patient has connective tissue disease. 6. Patient has a hypercoagulability disorder. 7. Patient is in acute renal failure. 8. Patient has active systemic infection. 9. Patient is less than 18 years old. 10. Patient has less than a one-year life expectancy. 11. Patient is participating in another research study involving an investigational agent for the treatment of Descending Thoracic Aortic Aneurysms. 12. Patient has other medical, social or psychological issues that in the opinion of the investigator preclude them from receiving this treatment, and the procedures and evaluations pre- and post-treatment. 13. Patient is unwilling or unable to return for or comply with follow-up visit schedules. |
Country | Name | City | State |
---|---|---|---|
United States | Stanford University School of Medicine | Stanford | California |
Lead Sponsor | Collaborator |
---|---|
Stanford University |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Stent graft migration | |||
Primary | Vessel Dissection or perforation | |||
Primary | Stent graft occlusion | |||
Primary | Collateral vessel occlusion | |||
Primary | Aneurysm rupture | |||
Primary | Aneurysm exclusion | |||
Secondary | Technical success | |||
Secondary | Patency |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT02777593 -
Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2
|
N/A | |
Completed |
NCT02876263 -
Noninvasive Neuromonitoring of Surgery of the Thoracic Aorta
|
N/A | |
Terminated |
NCT02538822 -
Risk of Rupture of Aneurysms of the Thoracic Ascending Aorta (ATA) From the Dynamic Imaging
|
N/A | |
Completed |
NCT04930172 -
TOtal tRansfemoral branCHed endovasCular tHoracoabdominal Aortic Repair Registry
|
||
Completed |
NCT03207568 -
RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU)
|
N/A | |
Recruiting |
NCT03010514 -
A Registry Study on Genetics and Biomarkers of Thoracic Aortic Aneurysm/Dissection
|
N/A | |
Completed |
NCT02266342 -
GORE® TAG® Thoracic Endoprosthesis French Mandatory Registry
|
||
Completed |
NCT00757003 -
To Evaluate the Safety and Efficacy for GORE TAG Thoracic Endoprosthesis in the Treatment of Thoracic Aortic Disease
|
Phase 3 | |
Recruiting |
NCT03574311 -
Preoperative Intravenous Ferric Carboxymaltose and Placebo in the Treatment of Patients Undergoing Cardiac Surgery
|
Phase 4 | |
Suspended |
NCT03410420 -
Detection of Hypoxia in Human Thoracic Aorta Using Pimonidazole Hydrochloride
|
Phase 1 | |
Recruiting |
NCT05703893 -
Investigation of the Neurovegetative Pattern in Patients With Thoracic Aortic Aneurysms (TAA)
|
||
Enrolling by invitation |
NCT05800743 -
Evaluation of the GORE® Ascending Stent Graft
|
N/A | |
Completed |
NCT02253082 -
Vasculopathic Injury and Plasma as Endothelial Rescue - OCTAplas Trial (EudraCT no. 2014-000452-28)
|
Phase 4 | |
Recruiting |
NCT02323581 -
Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts
|
N/A | |
Active, not recruiting |
NCT03414866 -
Thoraflex Hybrid Post-Market Study
|
||
Recruiting |
NCT01985906 -
Safety and Efficacy of Multiple Overlapping Uncovered Stents for Pararenal Aortic Aneurysm Repair
|
N/A | |
Active, not recruiting |
NCT02818972 -
RelayPro Thoracic Stent-Graft in Subjects With Thoracic Aortic Aneurysms and Penetrating Atherosclerotic Ulcers
|
N/A | |
Completed |
NCT03479164 -
Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms
|
N/A | |
Completed |
NCT01775046 -
Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
|
||
Recruiting |
NCT04814238 -
Minimally Invasive Aortic Root and Aorta surGery rEgistry
|