Clinical Trials Logo

Aortic Aneurysm, Thoracic clinical trials

View clinical trials related to Aortic Aneurysm, Thoracic.

Filter by:

NCT ID: NCT02625324 Completed - Clinical trials for Aortic Aneurysm, Thoracic

Valiant Evo International Clinical Trial

Start date: April 2016
Phase: N/A
Study type: Interventional

The purpose of the Valiant Evo International Clinical Trial is to demonstrate the safety and effectiveness of the Valiant Evo Thoracic Stent Graft System in subjects with a descending thoracic aortic aneurysm (DTAA) who are candidates for endovascular repair.

NCT ID: NCT02554032 Completed - Clinical trials for Aortic Aneurysm, Thoracic

The Aortic Surgery Cerebral Protection Evaluation (ACE) Randomized CardioLink-3 Trial

Start date: June 2015
Phase: N/A
Study type: Interventional

The ACE trial is a multicentre, randomized controlled trial comparing axillary vs. innominate artery cannulation for established antegrade cerebral perfusion in patients having aortic surgery (thoracic and aortic arch) requiring deep hypothermic circulatory arrest using a non-inferiority trial design.

NCT ID: NCT02538822 Terminated - Clinical trials for Aortic Aneurysm, Thoracic

Risk of Rupture of Aneurysms of the Thoracic Ascending Aorta (ATA) From the Dynamic Imaging

Start date: October 6, 2014
Phase: N/A
Study type: Interventional

Aneurysms of the thoracic ascending aorta are a serious pathology which may threatens life by rupture or dissection. Their incidence is estimated at 10.4 per 100,000 people. At present, the only parameter for assessing the risk of complication is the maximum diameter of the aneurysm. The only way to avoid a complication is a surgical replacement of the aneurysmal aorta by a prosthetic tube. This procedure is performed by sternotomy and with extracorporeal circulation and its death rate ranges between 3% and 5%. Surgical repair is indicated when the diameter of the aneurysm exceeds 5.5 cm for degenerative atheromatous aneurysms or 5 cm in a patient with genetic disorder of connective tissue (Marfan disease or Ehlers-Danlos syndrome). However, there are aneurysms with diameter greater than the surgical threshold which remain stable. Conversely, complications have been described for aneurysms less than 4.5 cm in diameter. The criterion of diameter appears therefore as inadequate to assess the risk of complication of an aneurysm of the ascending aorta.Multiple methods have been described in the literature. One of them relies on in vitro mechanical testing on healthy or aneurysmal tissue. Another method is the vivo analysis from imaging (CT, MRI or ultrasound). So far, no algorithm is robust enough for predicting the risk of complication better than the universally used criterion of diameter. The pathophysiology of these aneurysms has also been explored from histological studies. The investigators know that the microstructure of the aortic wall of an aneurysm is deteriorated with a degradation of elastin fibers and collagen that determine to a large extent its biomechanical behavior. Histological analysis appears inseparable from biomechanical analysis.

NCT ID: NCT02528500 Completed - Clinical trials for Thoracoabdominal Aortic Aneurysm

GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis in the Treatment of Type IV Thoracoabdominal Aortic Aneurysms

TAMBE
Start date: November 2015
Phase: N/A
Study type: Interventional

This study will assess the initial feasibility of the GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis (TAMBE Device) in the treatment of Aortic Aneurysms Involving the Visceral Branch Vessels.

NCT ID: NCT02365467 Active, not recruiting - Clinical trials for Aortic Aneurysm, Thoracic, Chronic Type B Dissection

Evaluation of the Valiant Mona LSA Thoracic Stent Graft System in Descending TAA and Chronic Dissections

Start date: April 16, 2015
Phase:
Study type: Interventional

The purpose of the Feasibility study is to characterize the safety of the Valiant Mona LSA Thoracic Stent Graft System, including an assessment of the safety and effectiveness of the device acutely and at the 30 day visit in the identified subject population. This study will also evaluate the current instructions for use and may direct changes to the delivery and deployment steps. The purpose of the expansion to the Feasibility Study is to characterize the Valiant Mona LSA Thoracic Stent Graft System, in particular to assess the safety and effectiveness of the device acutely and at the 30 day visit, in subjects enrolled with chronic, Type B dissections.

NCT ID: NCT02365454 Completed - Clinical trials for Thoracic Aortic Aneurysm

NEXUS™ Aortic Arch Stent Graft System First In Man Study

Start date: August 2014
Phase: N/A
Study type: Interventional

A multicenter, prospective, open-label, non-randomized, interventional clinical study, sponsored by Endospan Ltd. Patients will be followed-up for five years.

NCT ID: NCT02327611 Completed - Clinical trials for Thoracoabdominal Aortic Aneurysms

CUstodiol Versus RInger: whaT Is the Best Agent?

Start date: February 2015
Phase: Phase 4
Study type: Interventional

Postoperative renal failure is the most significant risk factor for early mortality after elective surgical repair of thoracoabdominal aortic aneurysms (TAAAs). To prevent damages related to kidney ischemia during aortic crossclamping and TAAA repair, the most recent guidelines recommend the use of cold crystalloid or blood perfusion. Since the most studied crystalloid solution is the Ringer's lactate solution, this can be considered the standard of care for evaluating the effectiveness of other substrates. An histidine-tryptophan-ketoglutarate enriched crystalloid solution named Custodiol (Dr. Franz Kohler Chemie GmbH, Bensheim, Germany) is currently used for organ preservation during transplantation and for cardioplegia during open-heart surgery in most EU countries. This solution may provide a better grade of renal protection to ischemic damage than the standard crystalloid solutions. A recent observational study published by our group suggested a lower incidence of postoperative renal kidney injury in patients undergoing open TAAA surgical repair using renal perfusion with Custodiol, as compared to those perfused with an enriched Ringer's lactate solution. Objective of this study is the confirmation of the promising findings about the effectiveness of renal perfusion with Custodiol during repair of TAAA compared with other crystalloid. The study will be a prospective, single-center, randomized, double-blind, controlled trial, investigating Acute Kidney Injury in patients undergoing TAAA open repair using Custodiol renal perfusion versus an enriched Ringer's lactate solution. It is expected to enroll adult patients undergoing elective TAAA open repair. Participants will be followed for the duration of hospital stay, an expected average of 2 weeks.

NCT ID: NCT02323581 Recruiting - Clinical trials for Aortic Aneurysm, Thoracic

Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts

Start date: November 2013
Phase: N/A
Study type: Interventional

Prospective, nonrandomized, single-center, two-arm study to assess the feasibility and safety and to evaluate clinical outcomes of endovascular repair of complex aortic aneurysms (thoracoabdominal aortic aneurysms and aortic arch aneurysms) in patients at high risk for open surgery.

NCT ID: NCT02299947 Terminated - Hemorrhage Clinical Trials

Bloodtranfusions After Aortic Surgery

FIBTEG
Start date: August 1, 2014
Phase: Phase 4
Study type: Interventional

The purpose of this study is to answer the following question: Leads a primary coagulation corrected with a single dose of fibrinogen concentrate after ascending aorta-arc reconstruction to a decrease in the number of allogenic blood transfusions, compared to placebo?

NCT ID: NCT02294435 Active, not recruiting - Clinical trials for Thoracoabdominal Aneurysms

Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms

Start date: February 2015
Phase: N/A
Study type: Interventional

The primary objective of the Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary device to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy. The primary intent of the study is to assess safety and preliminary effectiveness of the device. Additionally, the study will assess technical success and treatment success at each follow-up interval.