Clinical Trials Logo

Clinical Trial Summary

Aging is a physiological process. In the elderly, loss of functional reserve in all organ system, regression in anabolic processes and increase in catabolic processes are observed s (1). The number of geriatric patients is also increasing in our country. Technological developments in anesthesia and surgery technics show that we will provide medical services to more elderly patients over time(2). Cystatin C is excreted only by the kidney (7, 8). Serum cystatin C level is not affected by body muscle mass, age and gender. The half-life is short. Because of all these features, it is thought to be more sensitive than creatinine in evaluating kidney functions (8,9). In this study, it was aimed to compare the effects of low flow and normal flow desflurane anesthesia applied in geriatric patients on postoperative liver and kidney functions and serum cystatin C levels.


Clinical Trial Description

This prospective, randomized-controlled, observational study was approved by the ethics committee of Van Yuzuncu Yıl University (Date: 16.04.2021, Decision no: 05-27). The study was performed according to the World Medical Association's Declaration of Helsinki. All enrolled patients provided written informed consent. In this prospective study; the patients were randomly divided into 2 groups according to the fresh gas flow applied. 'Group D' (n=30) was given to the low flow anesthesia group; the group in which normal flow anesthesia was administered was named 'Group N' (n=30). Before anesthesia, automatic calibration of the anesthesia device (Primus, Drager) and leak tests were performed. In addition, the leak test was repeated manually for each patient. Alarm limits of the anesthesia device; The lower limit of inspired oxygen concentration (FiO2) was set to 30%, upper limit of inspired CO2 to 3%, and upper limit of end-tidal carbon dioxide (etCO2) to 45 mmHg. The disconnection alarm was set to be 5 cmH2O lower than the peak pressure, the occlusion alarm was set to 30 cmH2O, the lower expiratory gas volume lower limit was set to be 500 mL below the desired minute volume (MV). Soda lime (Sorbo-lime, Berkim, Turkey) was used as carbon dioxide absorbent. Soda lime was checked frequently for color and changed at appropriate times. Disposable anesthesia circuit and bacterial filter were used for each case. Electrocardiography (ECG), peak heart rate (CTA), peripheral oxygen saturation (SpO2), non-invasive blood pressure and bispectral index (BIS) monitorisation (A-2000 Aspect medical systems, USA) were performed on all patien. As a standard, vascular access was established with a 20-gauge (G) intraket from the dorsal of the hand or antecubital fossa in each patient and, a balanced electrolyte solution was infused of 8-10 ml/kg/hr. All patients were preoxygenated with 100% O₂ for three minutes. For anesthesia induction, 0.03 mg/kg midazolam, 1-1.5 mcg/kg fentanyl, 2 mg/kg propofol and 0.6 mg/kg rocuronium were administered iv. Intubation was performed after adequate muscle relaxation was achieved. During mechanical ventilation; Tidal volume, PEEP, respiratory rate, etCO₂, and inspiration:expiration ratio were adjusted to be 7-10 ml/kg, 5 cmH2O, 12-14/min, 30-40 mmHg, 1:2 respectively. Both groups were given a mixture of 50% O2 + 50% air + 6-7% desflurane in a 4 L/min fresh gas flow (FGF) until the minimum alveolar concentration (MAC) value was 1. When the MAC value of desflurane was 1, FGF was reduced to 0.5 L/min (60% O2+40% dry air+8% desflurane) in Group D. In Group N, anesthesia was maintained by reducing FGF to 2 liters per minute (40% O2+60% air+6% desflurane). It was aimed to keep the MAC value between 0.9-1.1 and BIS values between 40-60 by titration of desflurane in all patients. Hemodynamic data, SpO2 and BIS values of the patients were recorded. It was recorded before induction, after induction, when switching to low/normal flow anesthesia, and during extubation. Venous blood samples were obtained before induction, after surgery, and at the postoperative 24th hour to evaluate liver and kidney functions. The SPSS 27.0 program was used to evaluate the data obtained in this study. In the descriptive statistics of the data, mean, standard deviation, median minimum, maximum, frequency and ratio values were used. The distribution of variables was measured with the Kolmogorov-Smirnov test. The mann-whitney u test was used in the analysis of quantitative independent data. Wilcoxon test was used in the analysis of dependent quantitative data. Chi-square test was used in the analysis of qualitative independent data, and the fischer test was used when the chi-square test conditions were not met. Statistical significance value was accepted as p<0.05 in all tests. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05414721
Study type Interventional
Source Yuzuncu Yil University
Contact
Status Completed
Phase N/A
Start date May 28, 2021
Completion date March 30, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas