Anesthesia Clinical Trial
Official title:
Early Warning for Desaturation by Oxygen Reserve Index During Induction of General Anesthesia
During the induction of general anesthesia, the anesthesiologist needs to provide the oxygen supply to meet the patient's needs continuously. In the clinical scenario, the pulse oximeter is used as a standard to monitor hemoglobin oxygen saturation (SpO2) but is limited to assess the oxygenation status beyond the measurement of 100%. The Oxygen Reserve Index (ORi) is a dimensionless parameter between 0 and 1 that is related to real-time oxygenation reserve status. This study was designed to evaluate the duration of warning time for desaturation provided by different ORi alarm triggers during prolonged apnea in surgical patients. The primary endpoint was the duration of additional warning time provided by the ORi trigger. The secondary endpoint was the correlation of ORi and PaO2.
This is an observational study of the routine clinical practice with no specific additional interventions required. The investigators enrolled the American Society of Anesthesiologists (ASA) physical status I to III patients scheduled for elective surgery with planned arterial catheter placement before induction. Patients were positioned supine on the operating room table. Standard monitors and the ORi sensor were placed. The patients were preoxygenated with a facemask (flow rate of 8 to 10 liters/minute) for 3 minutes with spontaneous ventilation. Propofol (2-2.5 mg/kg), fentanyl (2-3 mcg/kg) and rocuronium (0.6-0.9 mg/kg) were administrated to achieve anesthesia induction during following 3 minutes. The patient was keeping ventilated manually by the anesthesiologist during the induction phase and intubated under direct visualization with a video-assisted laryngoscope at 6 minutes. The endotracheal tube was not connected to the breathing circuit to avoid apneic oxygenation. The patients remained apneic. Ventilation was resumed when SpO2 fell to 90%. ORi and SpO2 were recorded every ten seconds. Arterial blood is sampled every minute, from preoxygenation to resumed ventilation, to observe blood oxygen concentration changes. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04279054 -
Decreased Neuraxial Morphine After Cesarean Delivery
|
Early Phase 1 | |
Active, not recruiting |
NCT04580030 -
Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
|
||
Completed |
NCT03640442 -
Modified Ramped Position for Intubation of Obese Females.
|
N/A | |
Recruiting |
NCT04099693 -
A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
|
||
Terminated |
NCT02481999 -
Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
|
||
Completed |
NCT04235894 -
An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
|
||
Recruiting |
NCT05525104 -
The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen).
|
N/A | |
Recruiting |
NCT05024084 -
Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth
|
Phase 4 | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT03277872 -
NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
|
N/A | |
Terminated |
NCT03940651 -
Cardiac and Renal Biomarkers in Arthroplasty Surgery
|
Phase 4 | |
Terminated |
NCT02529696 -
Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
|
||
Completed |
NCT05346588 -
THRIVE Feasibility Trial
|
Phase 3 | |
Terminated |
NCT03704285 -
Development of pk/pd Model of Propofol in Patients With Severe Burns
|
||
Recruiting |
NCT05259787 -
EP Intravenous Anesthesia in Hysteroscopy
|
Phase 4 | |
Completed |
NCT02894996 -
Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient?
|
N/A | |
Completed |
NCT05386082 -
Anesthesia Core Quality Metrics Consensus Delphi Study
|
||
Terminated |
NCT03567928 -
Laryngeal Mask in Upper Gastrointestinal Procedures
|
N/A | |
Recruiting |
NCT06074471 -
Motor Sparing Supraclavicular Block
|
N/A | |
Completed |
NCT04163848 -
CARbon Impact of aNesthesic Gas
|