Clinical Trials Logo

Clinical Trial Summary

Many clinicians continue to rely on subjective evaluation in making decisions about the adequacy of neuromuscular function before tracheal extubation rather than using quantitative monitoring. The aim was to compare the sugammadex dose as suggested by senior anaesthesiologists (SSD) based on clinical experience versus the dose determined by quantitative monitoring (QSD) to determine if the subjective dose was appropriate.


Clinical Trial Description

Materials and Methods: After obtaining approval from the Institute Ethics Committee, a prospective 3-month study in patients aged 18-75 years who underwent general anesthesia with rocuronium (initial dose 0.6 mg/kg) NMB and subsequent reversal with sugammadex, was carried out. American Society of Anesthesiologists (ASA ) physical status V, emergency surgery, patients with hypersensitivity history to rocuronium or sugammadex, severe renal impairment/dialysis, neuromuscular diseases, severe hepatic disease, pre-existing coagulopathies and pregnancy were excluded. Monitoring included ASA standard monitoring, bispectral index and NMB monitoring using TOFscan® monitor. The senior anaesthesiologist was blinded to the TOFscan®, which was only available to the author. At the time of pharmacologic reversal of NMB, both the sugammadex dose proposed by the anaesthesiologist (SSD) and the dose suggested by TOFscan® (QSD) according to the Portuguese recommendations for the management of NMB were recorded. Afterwards the QSD was administered to overcome ethical issues. When train-of-four (TOF) count was 0, the author performed the post tetanic count (PTC) stimulus to determine the recommended dose. The SSD was considered appropriate if it was within 10% of the QSD for the depth of NMB. All patients were extubated with a TOF ratio > 0.9 (TOFr) and both the rocuronium and sugammadex dose were calculated based on the real patient weight. Data regarding anaesthesia, duration of anaesthesia and dosing pattern of rocuronium were also noted. The results were analysed descriptively. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04762420
Study type Observational
Source Hospital do Divino Espírito Santo de Ponta Delgada
Contact
Status Completed
Phase
Start date February 1, 2019
Completion date April 30, 2019

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas