Anesthesia Clinical Trial
Official title:
The Application of Response Surface Model on Sedative Endoscopic Retrograde Cholangiopancreatography and Sedative Bronchoscopy
The purpose of this study is to find the application of Response Surface Model on Sedative Procedures.
It is very important to understand the influence of drug interactions of patients in clinical anesthesia. However, there were only a few quantitative studies on the pharmacodynamics of different drug combinations and patient responses. In recent years, the investigators have innovatively utilized the response surface models in patients receiving painless gastro-intestinal endoscopies. Appropriate pharmacodynamic models of clinical anesthesia for these procedures provide observation, evaluation, and prediction of the pharmacodynamic effects of a combination of clinical anesthetics to such patients. Patients with endoscopic retrograde cholangiopancreatography (ERCP) and bronchoscopy often have a need for painless service, but current clinical studies of using a pharmacodynamic model were lacking in these patients. The investigators therefore design a two-year prospective, observational project to investigate the optimal drug concentration combinations for the shortest wake-up time, adequate analgesia, and appropriate depth of anesthesia for sedative endoscopic ERCP and sedative bronchoscopy using pharmacodynamic models. Multidimensional surface charting will be performed by inputting diversified parameters to predict the drug interactions of the model groups. In this prospective, observational study, the investigators plan to enroll 40 ASA Class Forty ASA Class II-III, aged 20-80 adult patients who require sedative ERCP and bronchoscopy. Moderate to heavy sedation will be performed only after patients' inform consents and approval of the institutional ethics committee. The investigators plan to complete this series of studies within two years: The first year: ERCP(10 patients) and broncoscopy (10 patients). The second year: ERCP(10 patients) and broncoscopy (10 patients). Using response surface models, this study will offer us novel information about patients during procedures which may substantially increase the anesthesia quality and outcome of sedative ERCP and broncoscopy. Physiological signals such as anesthesia depth, drug concentrations and dosages, alertness/sedation score, heart rate, blood pressure, peripheral oxygen saturation, and physical activity responses during painless procedures will be collected and then the above data will be applied to the response surface models. Then the investigators will find the most appropriate anesthetic response surface which may delineate the effects of drug combinations, and will further improve the anesthesia safety and quality for painless ERCP and bronchoscopy patients. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04580030 -
Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
|
||
Active, not recruiting |
NCT04279054 -
Decreased Neuraxial Morphine After Cesarean Delivery
|
Early Phase 1 | |
Completed |
NCT03640442 -
Modified Ramped Position for Intubation of Obese Females.
|
N/A | |
Recruiting |
NCT04099693 -
A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
|
||
Terminated |
NCT02481999 -
Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
|
||
Completed |
NCT04235894 -
An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
|
||
Recruiting |
NCT05525104 -
The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen).
|
N/A | |
Recruiting |
NCT05024084 -
Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth
|
Phase 4 | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT03277872 -
NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
|
N/A | |
Terminated |
NCT03940651 -
Cardiac and Renal Biomarkers in Arthroplasty Surgery
|
Phase 4 | |
Terminated |
NCT02529696 -
Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
|
||
Completed |
NCT05346588 -
THRIVE Feasibility Trial
|
Phase 3 | |
Terminated |
NCT03704285 -
Development of pk/pd Model of Propofol in Patients With Severe Burns
|
||
Recruiting |
NCT05259787 -
EP Intravenous Anesthesia in Hysteroscopy
|
Phase 4 | |
Completed |
NCT02894996 -
Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient?
|
N/A | |
Completed |
NCT05386082 -
Anesthesia Core Quality Metrics Consensus Delphi Study
|
||
Terminated |
NCT03567928 -
Laryngeal Mask in Upper Gastrointestinal Procedures
|
N/A | |
Recruiting |
NCT06074471 -
Motor Sparing Supraclavicular Block
|
N/A | |
Completed |
NCT04163848 -
CARbon Impact of aNesthesic Gas
|