Anesthesia Clinical Trial
Official title:
The Use of the Fluid IV Alert (FIVA) Monitor to Decrease the Incidence of Undetected Empty Intravenous Bag in Dimmed Operating Rooms
This study is being performed to determine the effectiveness of Fluid Intravenous Alert (FIVA) in monitoring intravenous fluid delivered to patients under anesthesia in a dimmed ambient light in the operating room.
Background and Rationale
The first intravenous (IV) system was developed by Dr. Thomas Latta in 1832 to treat Cholera
patients. Following its introduction, the IV delivery system has been widely adopted as a
means of fluid resuscitation, rehydration and administration of blood products, medications
and vasopressors. Today, it is a standard practice to place an IV catheter in all patients
requiring an operation in the hospital setting. Intravenous fluid is administered through the
IV tubing into the vein and carries the drugs that are needed for induction and maintenance
of anesthesia. This IV fluid comes in several varieties which contain different amount of
electrolytes, glucose, acidity or starch and is stored in a variety of volumes in sterile
bags (most commonly 500 ml and 1000 ml). Once connected to the IV catheter through the IV
tubing, the fluid bag is hung on the IV pole above the patient and flow into the patient by
gravity.
In the nursing wards, IV fluids are routinely administered via infusion pumps, which can
deliver fluid at specified rates and volumes and would sound alarms when the selected volumes
of fluid have been completed. While this is an effective means of administering IV fluid, it
is a time-consuming process to set up the IV fluid pump and program the infusion volume and
rate. Perioperative fluid administration is a rapidly changing process and most
anesthesiologists would prefer more control over the rate than pre-programed pumps. In the
operating room environment, the rate and manner of drug and fluid administration are highly
variable. Therefore, almost all IV fluid administered systems are gravity-fed.
In busy operating rooms, anesthesiologists carefully observe the progress of surgery and the
anesthetic state of patients through different monitors. Intravenous fluid bags often run
empty unnoticed because the IV fluid bags are hung above the eye level of the
anesthesiologist. Even a vigilant anesthesiologist may not be able to promptly detect dry the
IV fluid bag. In a previous observational study, the incidence of undetected dry IV bags has
been shown to be 29.6%. However, the length of time before an empty bag is noticed is
unknown. According to a recent survey about the working conditions in the operating room,
including 471 surgeons and 405 nurses, most of the reported intra-operative hazards were due
to insufficient illumination of the operating room especially during dangerous situations,
such as unexpected bleeding. In the presence of dimmed ambient light in the operating room,
e.g. during endoscopic surgeries, it is probably more difficult to visually monitor the flow
of IV fluid with higher incidence of undetected dry IV bags. Several potential clinical
adverse events can occur if the dry IV bag is not detected promptly. Firstly, if the
gravity-fed IV fluid is being used as a carrier to administer drugs, such as anesthetics for
total intravenous anesthesia (TIVA), or the infusion of vasopressors, awareness under
anesthesia or unstable hemodynamics may occur. Secondly, during fluid or volume
resuscitation, the IV fluid delivery system is frequently pressurized in order to deliver
fluid as quickly as possible to the unstable patient. The pressurized IV fluid bag can force
the air present in the IV fluid bag into the IV tubing when the fluid runs out. This can
potentially cause air embolism. Finally, undetected dry IV bags can disrupt fluid flow
through the catheter into the patient, allowing blood to pool around the catheter. If a clot
is formed, it will occlude the line and prevent any further fluid flow. This may necessitate
recannulation of the anesthetized patient during surgery which may be technically
challenging.
The FIVA™ (EngenuityMED, Halifax, Canada) is a small, handheld, battery operated, device
class I medical device in Canada. It is designed to alarm and alert the physician to change
the IV bag when the fluid level in the chamber of the IV set is low. It also functions to
stop the fluid flow through the gravity-fed tubing system when the alarm is triggered,
preventing air from entering the IV tubing.
We hypothesize that the FIVA would decrease the incidence of unnoticed dry IV bags during
surgery, particularly when the operating room lights are dimmed and would therefore decrease
the risks associated with undetected dry IV bags.
;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Active, not recruiting |
NCT04279054 -
Decreased Neuraxial Morphine After Cesarean Delivery
|
Early Phase 1 | |
| Active, not recruiting |
NCT04580030 -
Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
|
||
| Completed |
NCT03640442 -
Modified Ramped Position for Intubation of Obese Females.
|
N/A | |
| Recruiting |
NCT04099693 -
A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
|
||
| Terminated |
NCT02481999 -
Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
|
||
| Completed |
NCT04235894 -
An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
|
||
| Recruiting |
NCT05525104 -
The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen).
|
N/A | |
| Recruiting |
NCT05024084 -
Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth
|
Phase 4 | |
| Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
| Completed |
NCT03277872 -
NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
|
N/A | |
| Terminated |
NCT03940651 -
Cardiac and Renal Biomarkers in Arthroplasty Surgery
|
Phase 4 | |
| Terminated |
NCT02529696 -
Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
|
||
| Completed |
NCT05346588 -
THRIVE Feasibility Trial
|
Phase 3 | |
| Terminated |
NCT03704285 -
Development of pk/pd Model of Propofol in Patients With Severe Burns
|
||
| Recruiting |
NCT05259787 -
EP Intravenous Anesthesia in Hysteroscopy
|
Phase 4 | |
| Completed |
NCT02894996 -
Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient?
|
N/A | |
| Completed |
NCT05386082 -
Anesthesia Core Quality Metrics Consensus Delphi Study
|
||
| Terminated |
NCT03567928 -
Laryngeal Mask in Upper Gastrointestinal Procedures
|
N/A | |
| Recruiting |
NCT06074471 -
Motor Sparing Supraclavicular Block
|
N/A | |
| Completed |
NCT04163848 -
CARbon Impact of aNesthesic Gas
|