Clinical Trials Logo

Clinical Trial Summary

Anesthesia providers are taught to "test" that they can properly ventilate a patient's lungs before administering a neuromuscular blocking drug (NMBD), rendering the patient apneic. This is a traditional teaching, not based on empirical evidence. The investigators primary hypothesis is that ventilation after the administration of NMBDs is non-inferior with that before their administration with respect to the composite safety endpoint of inadequate (MVi) and dead-space only (Vds) ventilation.


Clinical Trial Description

The following will be carried out per routine standard of care:

The patient will be met in the pre-operative area by the attending anesthesiologist who interviews and examines the patient. A full explanation of the general anesthetic including risks and benefit will be given. Patients will be premedicated with 1-2 mg of midazolam at the discretion of the attending anesthesiologist. Once in the OR, standard American Society of Anesthesiology (ASA) monitors are established. At a minimum, this includes non-invasive monitoring of blood pressure by automated cuff, oxygen saturation via pulse oximetry, heart rate and rhythm by 3-lead continuous electrocardiographic tracing, core body temperature, expired carbon dioxide concentration, and depth of neuromuscular blockade when paralytic medications are used. Additional monitoring may be applied as deemed appropriate by the attending anesthesiologist on a case-by-case basis. At this time, the patient is given fentanyl 1-2 mcg/kg. After a period of breathing 100% oxygen by facemask (typically for 3 minutes or until the anesthesia monitor shows the exhaled concentration of oxygen to be >80%) and when the primary anesthesia team judges denitrogenation to be sufficient, anesthesia will be induced intravenously with propofol 2-3 mg/kg. Once the patient is unresponsive to a jaw thrust, the patient is ventilated via a facemask. If the anesthesia provider feels that ability to move air in and out of the patients lungs is difficult, the may reposition the mask on the patient's face, reposition the head, neck, or shoulders of the patient, or place a plastic oropharyngeal airway to maintain the mouth in an open position and to help keep the base of the tongue from obstructing the upper airway. A drug that causes muscle paralysis is given, which takes 1-5 minutes to work depending on the drug administered; during this period the patient continues to be ventilated by facemask. However, there is not standard for the timing of administration of the paralytic drugs as some anesthesia providers administer them near simultaneous to the administration of the other drugs used to induce anesthesia. Often, during this time, an inhaled anesthetic agent is started to avoid any gaps in the effect of the intravenous medications. Once the muscle relaxant works, a breathing tube is placed in the patient's windpipe, and ventilation occurs via the tube connected to a breathing machine.

The study deviates from the standard anesthesia care described above in the following ways:

Before the patient arrives in the operating room, a small plastic device called a pneumotachograph will be placed in-line between the facemask and the breathing circuit of the anesthesia machine. This allows measurements of airway pressure and volumes to be recorded in an accurate manner and later sent electronically to a computer for analysis. The in-line portion of the device is no larger than a typical circuit connector already used and does not hinder the performance of the anesthesia provider in any way. After routine intravenous induction, once the patient is unresponsive to a jaw thrust patients will be ventilated by facemask for 60 seconds. Breaths will be delivered using the breathing bag of the anesthesia circuit as would otherwise be performed. The airway managers will be asked to follow a treatment algorithm to resolve any difficulty encountered in providing mask ventilation. This algorithm represents common practice. After the initial 60 seconds, the medication to induce muscle paralysis will be given. A nerve stimulator placed on the patients wrist will then be turned on and will indicate when the medication has taken full effect and the patient is paralyzed. During this period of time, approximately 60-90 seconds, with the patients unconscious and apneic, their breathing will be supported as would otherwise be done. Post-paralysis, data collection will again begin and the anesthesia provider will start again breathing for the patient via a facemask as described in figure 2 for another 60 seconds. The operator will be blinded to the display on the ventilator machine, which provides information about the amount of air going in and out of the patients lungs, but will be able to monitor the patient's pertinent vital signs on the anesthesia machine. At all times, one member of the primary anesthesia team will have full access to all monitoring as would normally take place. After this time, the tracheal tube will be placed for the surgery.

Appropriate sizing of the adult facemask and oropharyngeal airway will be determined by the primary anesthesia team. All breaths will be delivered by hand ventilation using the breathing bag of the anesthesia machine. The returned tidal volume will be recorded for each minute of the study period from the pneumotachograph placed inline with the anesthesia circuit at the level of the mask/elbow connector interface as described above. The total time from induction to placement of a breathing tube will be 4-5 minutes and represents an additional minute of "study" time to the standard care. This timing was chosen as the investigators feel that it will provide sufficient information about ventilation volumes without unduly prolonging the anesthetic.

The study coordinator will remain in the room for the actual intubation to record its ease or difficulty per the report of the primary anesthesia provider. The act of placing the breathing tube is not part of the study protocol, however.

Data points to be collected:

Data regarding tidal volume, minute ventilation, airway pressures, and end-tidal carbon dioxide will be recorded directly by the in-line pneumotachograph and then loaded into an excel spreadsheet. No manual data collection will be necessary.

Data and Safety Monitoring Plan

The study may be terminated by the primary anesthesia team if the one or more of the following criteria are met:

1. Inadequate ventilation by clinical criteria (inadequate chest rise, no fogging in the mask, no positive tracing of end-tidal carbon dioxide and/or lack of measurable returned tidal volumes on).

2. Low oxygen saturation (< 90%).

3. If for any reason, the primary anesthesia team feel that in their clinical judgment, immediate tracheal intubation is warranted.

All unanticipated problems and adverse event will be recorded in the study sheet by a study coordinator. At the earliest time, each unanticipated problem and adverse event will be examined by at least 2 study investigators. In the event of an unanticipated problem of adverse effect (eg inadequate mask ventilation), back-up will be provided by the primary anesthesia team caring for the patient and may include placing a laryngeal mask airway or a surgical airway. These are the same provisions that would be made for any non-study case as mask ventilation by using one or two hands represents standard practice.

Statistical Considerations:

The investigators are aiming to show that administration of a neuromuscular blocking agent is "safe" with respect to mask ventilation. In other words, that the average exhaled tidal volume per breath over one minute after the administration of a NMBD will be non-inferior to that measured before their administration. At the time of the planning of this study, no studies had reported a mean±SD for tidal volumes before and after NMBDs. However, based upon a prior comparative trial of two different mask-hold techniques, the standard deviation (SD) of the average exhaled tidal volume after induction of anesthesia, using the anesthesia ventilator and a two-hand jaw-thrust mask hold technique was 130 mL. With the equivalence limit, d, set as 50 mL per breath, with a significance level (α) of 2.5% and a power (1-β) of 95%, a total sample size of 208 patients per group (before and after NMBD for a total sample of 416 study periods) were required. In other words, if there is truly no difference between the mask ventilation before and after NMBD, then 208 patients, each as their own control, are required to be 95% sure that the limits of a 2-sided 95% confidence interval will exclude a difference in means of >50 mL. ;


Study Design

Endpoint Classification: Safety Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02237443
Study type Interventional
Source University of Washington
Contact
Status Completed
Phase Phase 4
Start date August 2014
Completion date February 2015

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas