Clinical Trials Logo

Clinical Trial Summary

Nitrous oxide is a standard part of most anaesthetic breathing mixtures. It has often been assumed that it reduces the amount of oxygen reaching the lower parts of the lung. However the results of previous studies and of some computer modelling suggests the opposite may be true, and that oxygen levels in the blood are actually higher with nitrous oxide. This study seeks to determine whether nitrous oxide increases or decreases blood oxygen levels in anaesthetized patients.


Clinical Trial Description

The concentrating and second gas effects of nitrous oxide (N2O) uptake have been well described, and are produced by rapid uptake of N2O during the first several minutes of an inhalational anesthetic. This significantly increases alveolar and arterial O2 partial pressure. Theoretical modelling of alveolar gas exchange has predicted that these effects may not be transient but may be a persisting phenomenon. However, N2O is known to promote absorption atelectasis in poorly ventilated lung units.

This study, carried out pre-cardiopulmonary bypass in 20 patients undergoing coronary artery surgery, measures change in PaO2 after a minimum of 30 minutes of relaxant general anesthesia with a FIO2 of 30%. Patients are randomised to two groups. The intervention group has N2O introduced following baseline blood gas measurements, while the control group continued breathing an identical FIO2 in N2. The change in PaO2 in the two groups is the primary endpoint for comparison. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00146250
Study type Interventional
Source Austin Health
Contact
Status Completed
Phase Phase 4
Start date March 1, 2005
Completion date September 30, 2005

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas