View clinical trials related to Air Leakage.
Filter by:In 2007 the Thopaz digital drainage system was launched as one of the first chest tube drainage systems to utilize a digital rather than analog device. The digital system allows for stored data, objective measurement of air leaks as well as maintaining a constant pleural pressure. The adult literature describes multiple benefits of using a digital drainage system, only two studies to date have looked at pediatric patients. In the adult literature, reported benefits include shorter chest tube drainage times, decreased length of stay, cost savings and fewer chest x-rays. To date, there have been no prospective randomized controlled trials comparing digital versus analog chest tube drainage systems in pediatric patients. In addition, the only two pediatric studies which looked at the potential benefits of a digital drainage system only looked at its use in patients who underwent pulmonary resection. Thus, a gap in the literature exists for a prospective trial determining if there is benefit to using a digital vs analog drainage system in pediatric patients requiring a chest tube. The investigators hypothesize that pediatric patients who are placed on the Thopaz+ digital drainage system will have decreased duration of chest tube drainage, fewer chest x-rays and shorter duration of air leaks compared to patients using a traditional analog chest tube drainage system. This will be the first prospective randomized study exploring the potential benefits of using a digital chest tube drainage system in pediatric patients.
The study aims to identify specific or potential reasons that prolong the length of hospital stay after video-assisted thoracoscopic surgery lobectomy. The hypothesis is that patients who are still in hospital after video-assisted thoracoscopic surgery lobectomy are associated with prolonged air leak, infection, pneumonia, atrial fibrillation or other complications or social factors.
There is widespread acceptance that air in intravenous (IV) fluid tubing (lines) can pose a significant risk to patients.1 A rigorous literature search regarding sources of this air identified only anecdotal and non-clinical work regarding the presence and sources of air in IV tubing. Most published case studies have focused on air entrainment from accidental or inadvertent sources - empty IV fluid bags, incomplete priming of the tubing prior to infusion, and air-detection device failures, as examples. The sources (and volume) of air inside IV tubing during common surgical procedures or interventions have yet to be studied prospectively. Understanding the frequency and magnitude of the presence of unintended air in IV tubing is the first step in devising potential avoidance strategies for eliminating unintended air in IV tubing. This study was designed to identify both the sources and magnitude of air that occurs in IV tubing during routine surgical procedures.
To assess the clinical performance and safety of HEMOPATCH Sealing Hemostat in a post-marketing setting in cardiovascular, thoracic, urologic, neurological, and other general surgical procedures.