Age-related Cataract Clinical Trial
Official title:
Influence of Different Intraocular Lenses on IOL-capsular Complex After Cataract Surgery in Patients With High Myopia: a Clinical Observation Based on SS-OCT
The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.
The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. However, there is scarce evidence on characteristics and factors associated with clinically significant IOL decentration and tilt in highly myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04702802 -
Clinical Study to Evaluate the Safety of the Viscoelastic Substance PRO-149 When Used During Phacoemulsification, Compared to Healon® EndoCoat.
|
Phase 1 | |
Recruiting |
NCT05802550 -
Metabo-lipidomics of the Ocular Surface for Cataract Surgery
|
N/A | |
Recruiting |
NCT04246346 -
Effectiveness of Using Interactive Consulting System to Enhance Informed Choice
|
N/A | |
Recruiting |
NCT03340389 -
Dysfunctional Lens Index Serves as a Novel Surgery Decision Maker for Age-related Cataracts
|
N/A | |
Recruiting |
NCT04050644 -
Comparison of Treatment With Preservative-free Dexamethasone 0.1% (Monofree Dexamethason) and Diclofenac 0.1% (Dicloabak) Eye Drops Versus Preserved Dexamethasone 0.1% (Maxidex) and Diclofenac 0.1% (Voltaren Ophtha) Eye Drops After Cataract Surgery
|
Phase 4 | |
Not yet recruiting |
NCT05028530 -
Correlation Analysis of Lens Nucleus Density and Surgical Parameters Based on Ss-oct and Scheimpflug Technology
|
||
Completed |
NCT05573529 -
EDOF and Multifocal IOL Study
|
N/A | |
Recruiting |
NCT04711395 -
The Application of Lens Dysfunction Index (DLI) in the Timing of Age-related Cataract Surgery
|
||
Completed |
NCT04262596 -
Effectiveness of an Interactive Consulting System to Enhance Patients' Decision-making: A Randomized Controlled Trial
|
N/A | |
Recruiting |
NCT02817191 -
Effects of Holy-Comod and Tears Naturale Forte in Patients After Phaco+IOL
|
N/A | |
Completed |
NCT06266962 -
Comparing the Efficiency of Two Approaches in Patients at Risk of Developing Intraoperative Floppy Iris Syndrome
|
Phase 4 | |
Completed |
NCT05148741 -
Evaluation of Capsular Bag Shape Changes After Plate-haptic Intraocular Lens Implantation by SS-OCT
|
||
Active, not recruiting |
NCT03992807 -
A Decision Aid for Patients With Age-related Cataract
|
N/A | |
Recruiting |
NCT04443101 -
Effective Lens Position After Cataract Surgery
|
||
Completed |
NCT04187157 -
Association Between Light Spectrum and Survival After Cataract Surgery
|
||
Withdrawn |
NCT04163926 -
Optometric Follow-up After Cataract Surgery
|
N/A |