Clinical Trials Logo

Clinical Trial Summary

The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.


Clinical Trial Description

The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. However, there is scarce evidence on characteristics and factors associated with clinically significant IOL decentration and tilt in highly myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05255796
Study type Interventional
Source Wenzhou Medical University
Contact Pingjun Chang
Phone 18868410303
Email 364669877@qq.com
Status Recruiting
Phase N/A
Start date January 7, 2022
Completion date December 2022

See also
  Status Clinical Trial Phase
Completed NCT04702802 - Clinical Study to Evaluate the Safety of the Viscoelastic Substance PRO-149 When Used During Phacoemulsification, Compared to Healon® EndoCoat. Phase 1
Recruiting NCT05802550 - Metabo-lipidomics of the Ocular Surface for Cataract Surgery N/A
Recruiting NCT04246346 - Effectiveness of Using Interactive Consulting System to Enhance Informed Choice N/A
Recruiting NCT03340389 - Dysfunctional Lens Index Serves as a Novel Surgery Decision Maker for Age-related Cataracts N/A
Recruiting NCT04050644 - Comparison of Treatment With Preservative-free Dexamethasone 0.1% (Monofree Dexamethason) and Diclofenac 0.1% (Dicloabak) Eye Drops Versus Preserved Dexamethasone 0.1% (Maxidex) and Diclofenac 0.1% (Voltaren Ophtha) Eye Drops After Cataract Surgery Phase 4
Not yet recruiting NCT05028530 - Correlation Analysis of Lens Nucleus Density and Surgical Parameters Based on Ss-oct and Scheimpflug Technology
Completed NCT05573529 - EDOF and Multifocal IOL Study N/A
Recruiting NCT04711395 - The Application of Lens Dysfunction Index (DLI) in the Timing of Age-related Cataract Surgery
Completed NCT04262596 - Effectiveness of an Interactive Consulting System to Enhance Patients' Decision-making: A Randomized Controlled Trial N/A
Recruiting NCT02817191 - Effects of Holy-Comod and Tears Naturale Forte in Patients After Phaco+IOL N/A
Completed NCT06266962 - Comparing the Efficiency of Two Approaches in Patients at Risk of Developing Intraoperative Floppy Iris Syndrome Phase 4
Completed NCT05148741 - Evaluation of Capsular Bag Shape Changes After Plate-haptic Intraocular Lens Implantation by SS-OCT
Active, not recruiting NCT03992807 - A Decision Aid for Patients With Age-related Cataract N/A
Recruiting NCT04443101 - Effective Lens Position After Cataract Surgery
Completed NCT04187157 - Association Between Light Spectrum and Survival After Cataract Surgery
Withdrawn NCT04163926 - Optometric Follow-up After Cataract Surgery N/A