Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT06169735
Other study ID # IRB-300011872
Secondary ID
Status Recruiting
Phase Phase 4
First received
Last updated
Start date April 11, 2024
Est. completion date May 1, 2025

Study information

Verified date April 2024
Source University of Alabama at Birmingham
Contact Zhixing Song, MD
Phone 2012535667
Email zhixingsong@uabmc.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The aim of this study is to determine if fluorescence with or without indocyanine green can facilitate safe and accurate thyroid and parathyroid surgery.


Description:

The accurate identification of the parathyroid gland is a crucial aspect of thyroid and parathyroid surgery. Failing to recognize the parathyroid gland during thyroidectomy can result in the inadvertent removal of the gland, leading to postoperative hypocalcemia. On the other hand, during parathyroidectomy, there is a risk of mistaking other structures, such as lymph nodes, for parathyroid adenomas, which can leave the patient without a cure. Currently UAB employs intraoperative PTH or radioactive isotope techniques in conjunction with surgeon judgment. However, both methods have limitations, including being time-consuming, posing logistical challenges, and not providing feedback before gland removal. Parathyroid fluorescence is a relatively new technology. It was initially discovered that the parathyroid gland emits fluorescence, which distinguishes it from the surrounding tissues. Additionally, indocyanine green dye is readily taken up by the parathyroid gland, making its detection easy to the naked eye. Research has demonstrated that parathyroid fluorescence, with or without indocyanine green, is not only safe but also helps reduce postoperative hypocalcemia and locate lesions in patients with imaging-negative parathyroid adenomas. However, the current use of parathyroid fluorescence is not standardized, and further studies are needed to explore its clinical utility in terms of cure rates and postoperative complications.


Recruitment information / eligibility

Status Recruiting
Enrollment 417
Est. completion date May 1, 2025
Est. primary completion date May 1, 2025
Accepts healthy volunteers No
Gender All
Age group 19 Years and older
Eligibility Inclusion Criteria: - age greater than 18 years old Exclusion Criteria: - Patients with iodine or shellfish allergies would be excluded. - Patients with allergy to indocyanine green. - Pregnancy

Study Design


Related Conditions & MeSH terms


Intervention

Drug:
Indocyanine green
ICG Administration: All enrolled patients with scheduled thyroidectomy or parathyroidectomy will receive a standard cervical incision that afford access to either side of neck. Following sufficient exposure of thyroid, 25 mg of indocyanine green (ICG), reconstituted in 10 ml of sterile water, will be administered intravenously. A dosage of 1 ml of this solution will be injected into a peripheral IV line, followed by a 5 ml flush of normal saline to ensure the propagation of the dye within the vascular compartment.
Device:
SPY Portable Handheld Imaging
Fluorescent Imaging: Approximately 30 seconds post-administration, the parathyroid glands are expected to exhibit fluorescence under near-infrared imaging. The emitted fluorescence is anticipated to persist for approximately 20 minutes, allowing ample time for intraoperative evaluation of parathyroid viability and perfusion

Locations

Country Name City State
United States UAB Callahan Eye Birmingham Alabama

Sponsors (2)

Lead Sponsor Collaborator
University of Alabama at Birmingham Stryker Nordic

Country where clinical trial is conducted

United States, 

References & Publications (8)

Carter Y, Chen H, Sippel RS. An intact parathyroid hormone-based protocol for the prevention and treatment of symptomatic hypocalcemia after thyroidectomy. J Surg Res. 2014 Jan;186(1):23-8. doi: 10.1016/j.jss.2013.09.026. Epub 2013 Oct 8. — View Citation

Chernock RD, Jackson RS. Novel Cause of 'Black Thyroid': Intraoperative Use of Indocyanine Green. Endocr Pathol. 2017 Sep;28(3):244-246. doi: 10.1007/s12022-016-9458-z. — View Citation

DeLong JC, Ward EP, Lwin TM, Brumund KT, Kelly KJ, Horgan S, Bouvet M. Indocyanine green fluorescence-guided parathyroidectomy for primary hyperparathyroidism. Surgery. 2018 Feb;163(2):388-392. doi: 10.1016/j.surg.2017.08.018. Epub 2017 Nov 10. — View Citation

Desiato V, Melis M, Amato B, Bianco T, Rocca A, Amato M, Quarto G, Benassai G. Minimally invasive radioguided parathyroid surgery: A literature review. Int J Surg. 2016 Apr;28 Suppl 1:S84-93. doi: 10.1016/j.ijsu.2015.12.037. Epub 2015 Dec 23. — View Citation

Edafe O, Antakia R, Laskar N, Uttley L, Balasubramanian SP. Systematic review and meta-analysis of predictors of post-thyroidectomy hypocalcaemia. Br J Surg. 2014 Mar;101(4):307-20. doi: 10.1002/bjs.9384. Epub 2014 Jan 9. — View Citation

Noureldine SI, Gooi Z, Tufano RP. Minimally invasive parathyroid surgery. Gland Surg. 2015 Oct;4(5):410-9. doi: 10.3978/j.issn.2227-684X.2015.03.07. — View Citation

Paras C, Keller M, White L, Phay J, Mahadevan-Jansen A. Near-infrared autofluorescence for the detection of parathyroid glands. J Biomed Opt. 2011 Jun;16(6):067012. doi: 10.1117/1.3583571. — View Citation

Silver Karcioglu AL, Triponez F, Solorzano CC, Iwata AJ, Abdelhamid Ahmed AH, Almquist M, Angelos P, Benmiloud F, Berber E, Bergenfelz A, Cha J, Colaianni CA, Davies L, Duh QY, Hartl D, Kandil E, Kim WW, Kopp PA, Liddy W, Mahadevan-Jansen A, Lee KD, Mannstadt M, McMullen CP, Shonka DC Jr, Shin JJ, Singer MC, Slough CM, Stack BC Jr, Tearney G, Thomas G, Tolley N, Vidal-Fortuny J, Randolph GW. Emerging Imaging Technologies for Parathyroid Gland Identification and Vascular Assessment in Thyroid Surgery: A Review From the American Head and Neck Society Endocrine Surgery Section. JAMA Otolaryngol Head Neck Surg. 2023 Mar 1;149(3):253-260. doi: 10.1001/jamaoto.2022.4421. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Percentage of Parathyroid Glands identified by ICG Measuring the percentage of the number of glands per participant that emit fluorescence.
ICG Administration: All enrolled patients with scheduled thyroidectomy or parathyroidectomy will receive a standard cervical incision that afford access to either side of neck. Following sufficient exposure of thyroid, 25 mg of indocyanine green (ICG), reconstituted in 10 ml of sterile water, will be administered intravenously. A dosage of 1 ml of this solution will be injected into a peripheral IV line, followed by a 5 ml flush of normal saline to ensure the propagation of the dye within the vascular compartment.
Fluorescent Imaging: Approximately 30 seconds post-administration, the parathyroid glands are expected to exhibit fluorescence under near-infrared imaging. The emitted fluorescence is anticipated to persist for approximately 20 minutes, allowing ample time for intraoperative evaluation of parathyroid viability and perfusion.
20 minutes
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05551052 - CRC Detection Reliable Assessment With Blood
Recruiting NCT02545699 - Prospective Trial to Compare ADR of G-EYE™ Colonoscopy With Standard Colonoscopy N/A
Completed NCT01802008 - Comparison of Adenoma Detection Miss Rates at Colonoscopy Associated With Different Withdrawal Times N/A
Recruiting NCT01211132 - Cap Assisted Colonoscopy for the Detection of Colon Polyps N/A
Completed NCT04287335 - Multitarget Stool FIT-DNA Study for Colorectal Cancer Early Screening in China
Recruiting NCT05362344 - Colorectal Cancer Screening in Cystic Fibrosis
Completed NCT03268200 - The Effect of Segmental Re-examination of Colon for Adenoma Detection in Colonoscopy N/A
Recruiting NCT04591145 - Multi-center Validation of a Deep Learning Based Bowel Preparation Evaluation System
Completed NCT02978664 - The Impact of Distraction on Adenoma Detection Rate N/A
Completed NCT00018551 - Chemoprevention With Folic Acid Phase 2
Recruiting NCT05594576 - Comparison of the ENDOCUFF VISION® Endoscopy Cap Coupled With GI GENIUS™ Artificial Intelligence Compared to Each Device Alone in Improving Colonic Adenoma Detection Rate During Colonoscopy N/A
Not yet recruiting NCT04135716 - A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy N/A
Recruiting NCT02288962 - Dopamine Agonist Treatment of Non-functioning Pituitary Adenomas Phase 3
Recruiting NCT02552017 - Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities N/A
Completed NCT02066064 - G-Eye Advanced Colonoscopy For Increased Polyp Detection Rate-randomized Tandem Study With Different Endoscopist N/A
Completed NCT01749722 - Safety and Efficacy of the NaviAid™ G-Eye System During Colonoscopy N/A
Withdrawn NCT01546259 - Water Method in Low-body Mass Index (BMI) Female Patients With Unsedated Colonoscopy N/A
Completed NCT01485133 - Water Method Colonoscopy in Patients With Prior Surgery N/A
Withdrawn NCT01546246 - Water Method in Patients With Incomplete Colonoscopy N/A
Withdrawn NCT01546220 - Water Method in Elder Patients With Unsedated Colonoscopy N/A