Adenoma Detection Rate Clinical Trial
Official title:
Comparison of Newer Colonoscopy Devices With Standard Forward Viewing (SFV) High Definition Colonoscopes in Daily Practice
Retrospective data analysis of comparsion of 3 types of colonoscopes in daily practice (FUSE Full spectrum colonoscopy with 330° angle of view vs Pentax standard HD-colonoscopes and Pentax plus Endocuff): medical device of the category IIb (CE-marked device used within its intended purpose)
From March 2015 through February 2017 (phase A) patients referred for ambulant colonoscopy in a private Swiss gastroenterologist's practice were alternatingly allocated to one of the two endoscopy theatres. One equipped with a FUSE® endoscopy system from Endochoice (later: Boston Scientific, nA/FUSE®=1044 examinations), the other with an EPKi Processor and Pentax i10 colonoscopes (nA/Pentax=934 examinations). In March 2017 a second doctor joined the practice, but did not contribute to the study. These organizational changes required randomization to be switched from per-patient alternation to per-day alternation in phase B from March 2018 through September 2019. In phase B the FUSE® system was unchanged (nB/FUSE®=1386 examinations), while the Pentax i10 colonoscopes were additionally equipped with Endocuff® (nB/Endocuff®=750 examinations). Patients with contraindica-tion against Endocuff® (known or found diverticular stenosis) were excluded from the study (nB/removed=127). Patients were given their appointments to any free slot throughout the week without stratification. The study and data analysis was consented by the ethical committee EKNZ Ethikkom-mission Nordwest- und Zentralschweiz (Project-ID 2019-01643). All procedures were performed by one experienced endoscopist (board certified 2004) under nurse assisted propofol sedation (NAPS). Baseline characteristics, age, sex, BMI, smoking habits, diabetes as well as quality of bowel prepara-tion (measured by BBPS score) and indication for colonoscopy (screening, surveillance, diagnostic, such as diarrhea, bleeding, persistent abdominal pain) were assessed. Amount of sedatives, other medications given during endoscopy (e.g. Buscopan®) and time for the endoscopy e.g. time to ile-um, retraction time (pullback time minus intervention time) and time for intervention were measured by the assistant with a stopwatch. These parameters, polyp counts, size and their localisation (entered in a table and to an anatomical scheme), and satisfaction for all parts of the examination (bowel prep and overall satisfaction) were realtime entered to the database by a tablet computer. The data entry was done coded. Only the main investigator could subdue each single patient. Statistics were done with a professional statistics, the co-author Dr. Leiner ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03442738 -
A Prospective Randomized Comparison of the Adenoma Detection Rate With a Disposable Cap (ENDOCUFF VISION®)
|
||
Completed |
NCT03041532 -
Impact of Proximal Colon Retroflexion in Colorectal Cancer Screening Programme
|
N/A | |
Not yet recruiting |
NCT05141773 -
Artificial Intelligence Aid Systems and Endocuff in Colorectal Adenoma Detection
|
N/A | |
Completed |
NCT03137277 -
A Study Between Two Instrument Generations to Improve Adenoma Detection in Screening Colonoscopy
|
||
Recruiting |
NCT05125939 -
Can Overall Adenoma Detection Rate Replace Screening Adenoma Detection Rate ? Multicenter Study
|
||
Completed |
NCT04945044 -
Artificial Intelligence Aid Systems in Colorectal Adenoma Detection
|
N/A | |
Recruiting |
NCT05863208 -
Artificial Intelligence-assisted Colonoscopy With or Without Endocuff Vision
|
N/A | |
Recruiting |
NCT04963010 -
Impact of SFV of Proximal Colon on ADR
|
N/A | |
Completed |
NCT04086706 -
Retroflexion In The Ascending Colon Is A Costless Endoscopic Maneuver Increasing Adenoma Detection Rate
|
||
Not yet recruiting |
NCT03185299 -
Impact of Reinforced Education by Video on the Quality of Bowel Preparation
|
N/A | |
Completed |
NCT02507037 -
Effect of Gum Chewing on Bowel Cleansing Before Colonoscopy
|
Phase 4 | |
Completed |
NCT02540239 -
Premedication Simethione Improves Visibility During Bowel Cleansing for Colonoscopy
|
N/A | |
Completed |
NCT04397120 -
The Factors Affecting ADR of Screening Colonoscopy
|
||
Completed |
NCT01786213 -
Training Effects in Colonoscopy
|
N/A | |
Completed |
NCT06173297 -
Assessing the Agreement Between Endoscopic and Histopathological Diagnosis of Colorectal Sessile Serrated Lesions.
|
||
Not yet recruiting |
NCT03352700 -
Premedication Dyclonine Improves Visibility During Bowel Cleansing for Colonoscopy
|
Phase 4 | |
Not yet recruiting |
NCT03356015 -
Comparison Between 3-L and 4-L Polyethylene Glycol in Bowel Preparation
|
Phase 4 | |
Recruiting |
NCT04102631 -
A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
|
N/A | |
Not yet recruiting |
NCT02832869 -
Impact of Reinforced Education by Wechat and Short Message Service on the Quality of Bowel Preparation
|
Phase 4 |