Clinical Trials Logo

Clinical Trial Summary

The main purpose of the study to evaluate the usefulness of the Endo-AID artificial intelligence system in the detection of colorectal adenomas in consecutive patients for outpatient colonoscopy. The secondary aims were: - To evaluate the benefit of Endo-AID in adenoma detection rate by comparing endoscopists with high and low adenoma detection rate. - To evaluate serrated detection rate, advanced adenoma detection rate, adenoma detection rate according to the size (<= 5mm, 6-9mm,> = 10mm) and number of adenomas by colonoscopy. Stratification by location and morphology.


Clinical Trial Description

Priority guidelines have been established regarding IA applied to gastrointestinal endoscopy. Regarding the priority uses for their development, there are applications that improve vision, placing computer-assisted lesion detection (CADe) as one of the most necessary priorities, given the importance of colorectal cancer screening (CRC) and post-polypectomy surveillance. The evaluation of these systems in different clinical practices and patient groups has been recommend. In this regard, studies in the western population are limited and have been carried out by expert endoscopists. It has not been evaluated in endoscopists with different adenoma detection rates. In addition, there are no studies with the recent CADe Endo-AID system (Olympus Corp. Tokyo). The main purpose of the study to evaluate the usefulness of the Endo-AID artificial intelligence system in the detection of colorectal adenomas in consecutive patients for outpatient colonoscopy. In addition, the benefit of the CADe system will be assessed according to the endoscopist ADR. A randomized controlled trial will be carried out in consecutive outpatients meeting the inclusion criteria and none of the exclusion criteria. Patients with be randomized to one of the four groups: CADe system and high ADR endoscopist; CADe system and low ADR endoscopist; Control and high ADR endoscopist; Control and low ADR endoscopist. For the sample size calculation a 14.4 of difference in favor of the CADe system was considered. Taking onto account an alpha error of 0.05 in a unilateral contrast, a power of 80% and a loss of 10%, 165 patients per group would be required. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04945044
Study type Interventional
Source Hospital Universitario de Canarias
Contact
Status Completed
Phase N/A
Start date November 15, 2021
Completion date January 31, 2022

See also
  Status Clinical Trial Phase
Completed NCT03442738 - A Prospective Randomized Comparison of the Adenoma Detection Rate With a Disposable Cap (ENDOCUFF VISION®)
Completed NCT03041532 - Impact of Proximal Colon Retroflexion in Colorectal Cancer Screening Programme N/A
Not yet recruiting NCT05141773 - Artificial Intelligence Aid Systems and Endocuff in Colorectal Adenoma Detection N/A
Completed NCT03137277 - A Study Between Two Instrument Generations to Improve Adenoma Detection in Screening Colonoscopy
Recruiting NCT05125939 - Can Overall Adenoma Detection Rate Replace Screening Adenoma Detection Rate ? Multicenter Study
Recruiting NCT05863208 - Artificial Intelligence-assisted Colonoscopy With or Without Endocuff Vision N/A
Completed NCT04472741 - Comparison of Newer Colonoscopy Devices With Standard Forward Viewing (SFV) Colonoscopes in Daily Practice N/A
Recruiting NCT04963010 - Impact of SFV of Proximal Colon on ADR N/A
Completed NCT04086706 - Retroflexion In The Ascending Colon Is A Costless Endoscopic Maneuver Increasing Adenoma Detection Rate
Not yet recruiting NCT03185299 - Impact of Reinforced Education by Video on the Quality of Bowel Preparation N/A
Completed NCT02507037 - Effect of Gum Chewing on Bowel Cleansing Before Colonoscopy Phase 4
Completed NCT02540239 - Premedication Simethione Improves Visibility During Bowel Cleansing for Colonoscopy N/A
Completed NCT04397120 - The Factors Affecting ADR of Screening Colonoscopy
Completed NCT01786213 - Training Effects in Colonoscopy N/A
Completed NCT06173297 - Assessing the Agreement Between Endoscopic and Histopathological Diagnosis of Colorectal Sessile Serrated Lesions.
Not yet recruiting NCT03352700 - Premedication Dyclonine Improves Visibility During Bowel Cleansing for Colonoscopy Phase 4
Not yet recruiting NCT03356015 - Comparison Between 3-L and 4-L Polyethylene Glycol in Bowel Preparation Phase 4
Recruiting NCT04102631 - A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy N/A
Not yet recruiting NCT02832869 - Impact of Reinforced Education by Wechat and Short Message Service on the Quality of Bowel Preparation Phase 4