Clinical Trial Summary

The goal of this non-inferiority observational study is to assess the diagnostic performance of low-dose CT with deep learning image reconstruction (DLIR) in adult participants with acute abdominal conditions. The main research question is: • Can low-dose CT with DLIR achieve the same diagnostic performance as standard CT for the diagnosis of acute abdominal conditions. Participants will be examined with an additional low-dose CT directly after the standard CT. Participant will be their own controls.


Clinical Trial Description

Background Computed Tomography (CT) has become an essential tool in modern clinical medicine. With widespread availability, a rapid increase in the use of CT imaging has been observed over the last decades. With the associated increase in radiation exposure, the potential increased risk for radiation-induced malignancy has become a public health concern. This is especially true for CT scans of the abdomen and pelvis which currently account for 50% of the collective CT dose. As the benefit of dose reduction in general is offset by deterioration of image quality, technological advances to reduce radiation dose without compromising image quality are aspired in clinical practice. In CT-image reconstruction, filtered back projection (FBP) has been the dominant image reconstruction technique algorithm since the early 1970s, complemented by the first commercial iterative reconstruction (IR) algorithms in 2009. A novel deep learning image reconstruction (DLIR) algorithm received clinical approval in 2019 (TrueFidelity, GE Healthcare, Milwaukee, WI). Other vendor-specific algorithms for deep learning image reconstruction are also emerging (AiCE, Canon Medical Systems, Otawara, Japan). As explained by a technical white paper, having been trained with high-dose and low-dose FBP datasets across phantom and patient cases, the DLIR algorithm strives to suppress image noise without compromising image quality. The use of deep learning image reconstruction has demonstrated potential for improved image quality and dose reduction without shifting noise texture. For patients with acute abdominal conditions, CT of the abdomen and pelvis is considered the best first- or second-line diagnostic approach. For these patients a fast and accurate diagnosis is of great importance to avoid treatment delay and subsequent complications such as gastrointestinal perforation in case of appendicitis or diverticulitis. On the other hand, it is also important to avoid unnecessary surgical intervention and the related complications. A possible low-dose CT protocol must therefore provide a non-inferior diagnostic performance to facilitate fast diagnosis and avoid overtreatment and inconclusive examinations. Promising results have been reported regarding low-dose CT examinations with model-based IR and dose reduction of up to 75-80%. However, with the introduction of DLIR even further dose reduction seems feasible. Our own results from an image quality perception study with DLIR indicate that a dose reduction of up to 92.5% compared to standard CT might preserve acceptable diagnostic image quality (yet unpublished work). On this basis, the purpose of this study is to assess the diagnostic performance of low-dose CT with DLIR for the diagnosis of acute abdominal conditions in a non-inferiority setting with a large sample size provided by two major trauma centers in northern Europe. Aims Primary: To evaluate the diagnostic performance for acute abdominal conditions of contrast enhanced low-dose CT with DLIR "TrueFidelity" (TF) compared to standard full-dose CT. Secondary: To evaluate technical and perceived image quality (qualitatively and quantitatively). Ethics Approval will be obtained from the regional ethics committee and the institutions data protection officer. Written informed consent will be obtained from all participants. This project will be in accordance with the Helsinki Declaration. Risks Minimal risks exist due to a slight increase in radiation exposure. The additional radiation exposure of 27.5% is within the national variation of radiation exposure from CT exams performed for corresponding clinical tasks. The investigators estimated the mean additional effective dose to 1.5 mSv which corresponds to about 4 months with natural background radiation exposure in Norway (4.1 mSv/year). The additional radiation exposure translates into a theoretical excess lifetime risk of deadly radiation induced cancer between 0.004 - 0.03%. The clinical risks from this exposure are considered to be minimal/not significant. Material and Methods The study will be registered at ClinicalTrials.gov prior to initiation. Study methods and results will be reported in agreement with the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement of 2015. It should be noted that the STARD-AI Steering Group is preparing an AI-specific extension. If these STARD-AI guidelines are published before end of study, the findings will also be reported in accordance herewith. To compensate for AI specific elements not addressed in STARD, the investigators will, when relevant, rely on the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) which is modelled after the STARD guideline. Pilot A study pilot including 10 patients divided equally between Oslo and Odense will be performed to allow for testing of study logistics and adjustments of the radiation dose level of the low-dose CT. Examination protocol / imaging Examinations will be carried out according to local routine procedures and established CT protocols (CT scanner: GE Revolution). In addition to the CT with standard examination protocol a low-dose CT scan will be performed, not exceeding 30% radiation dose of the standard CT. Low-dose CT images will be reconstructed with TF high. The low dose CT will be performed directly after the standard CT to avoid bias from differences in the timing of the contrast phase. Location and local study population The study will be carried out as a multicenter study involving Oslo and Odense with prospective data collection. The estimated total study population will be divided equally between the two Hospitals. Image evaluation The low-dose CT will not be used for diagnostic purposes or patient treatment. Image evaluation and comparison will be conducted separated from clinical routine workflow. All low-dose CT exams will be evaluated independently by two resident radiologists and by two experienced radiologists specialized in abdominal radiology with more than 10 years of experience in abdominal CT. The readers will be blinded for all information from previous exams, the primary CT report, any finding by the other readers, all treatment related information and for the final diagnosis. They will have access to clinical referrals and laboratory tests performed prior to the original CT examination. Image evaluation will be performed in the radiologists' clinical environment using diagnostic monitors. In the outcome analysis, the diagnosis for each patient from low dose CT will be compared to the original radiological diagnosis based on full dose CT. For intra reader agreement a random selection from 10% of the cases will be presented twice to each reader. Technical image quality is assessed by positioning regions of interest (ROI) in a homogeneous segment of the portal vein, adjacent normal liver parenchyma aorta, erector spinae muscles and in the subcutaneous fat. Contrast-to-Noise Ratio (CNR) will be calculated. Perceived image quality will be assessed by at least two radiologists on a Likert-type scale along image quality criteria based on the European guidelines for image quality in abdominal CT. Statistics Dedicated statistical software like Stata and SPSS will be used for analysis of study data. The alpha significance level will be set to 5% and 95% confidence intervals will be used. Kappa statistics will be used for inter and intra reader agreement. Logistic regression will be used for image quality assessment. Appropriate parametric or non-parametric tests will be used for evaluation of numeric variables. The diagnostic performance will be defined by area under the curve, sensitivity, specificity, positive and negative predictive value. Significant differences in sensitivity and specificity will be determined by McNemar's test. Power calculation and sample size A non-inferiority study design will be used to show noninferiority regarding the diagnostic performance of the low-dose CT compared to standard CT. The investigators estimated the sensitivity of the standard CT to 90%. The prevalence of acute abdominal conditions with a visible correlate on standard CT is estimated to 70% among all referrals meeting inclusion criteria. A non-inferiority margin of 10% for sensitivity was considered as clinical acceptable i.e. the probability for positive findings on low-dose CT in case of positive standard CT was assumed to be 90%. S_L = Probability (positive low-dose CT | positive standard CT) The 0-hypothesis was defined as: S_L < 90% The alternative hypothesis was then defined as: S_L > 90% To identify a one-sided 6% difference (increase) from the non-inferiority margin with a power of 80% and an alpha significance level of 5%, the investigators estimated the required patients with positive CT findings to n=116 (binominal distribution). The total number of required patients was then calculated to 116/0.7=166. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05651360
Study type Observational
Source Oslo University Hospital
Contact
Status Completed
Phase
Start date December 7, 2022
Completion date July 10, 2023

See also
  Status Clinical Trial Phase
Completed NCT04484610 - Appropriate Opioid Quantities for Acute Pain - Pharmacist Study Phase 4
Recruiting NCT05054179 - Pecto-Intercostal Fascial Plane Block Catheter Trial for Reduction of Sternal Pain Phase 2/Phase 3
Completed NCT04548635 - VR for Burn Dressing Changes at Home Phase 2/Phase 3
Recruiting NCT05370404 - Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain: N/A
Completed NCT06054945 - Clinical Impact of IPACK Block Addition to Suprainguinal Fascia Iliaca Block
Completed NCT03825549 - A Randomized Trial of Behavioral Economic Approaches to Reduce Unnecessary Opioid Prescribing N/A
Completed NCT05995912 - Efficacy and Safety of Etoricoxib-tramadol Tablet in Acute Postoperative Pain Phase 2
Recruiting NCT05589246 - Regional Analgesia in Combination With Cryoanalgesia to Prevent Acute Pain Following Nuss Procedure N/A
Recruiting NCT05572190 - Evaluate the Safety and Pharmacokinetic Profile of ETR028 and ETR029 in Healthy Adult Subjects Phase 1
Terminated NCT04716413 - Evaluating the Use of Sublingual Sufentanil in Patients With Suboxone Treatment Phase 4
Active, not recruiting NCT03537573 - Provider-Targeted Behavioral Interventions to Prevent Unsafe Opioid Prescribing for Acute Pain in Primary Care N/A
Not yet recruiting NCT06317844 - Examination of Psychological and Physiological Pathways Linking Gratitude and Pain N/A
Withdrawn NCT02957097 - Gabapentin as a Pre-emptive Analgesic in Oral and Maxillofacial Surgical Procedures Phase 4
Completed NCT02565342 - Interscalene Brachial Plexus Block to Treat Pain After Clavicular Surgery Phase 4
Terminated NCT02599870 - Clinical Study to Evaluate Clinical Impact of PGx-Guided Treatment for Patients Undergoing Elective Spinal Surgical Procedures N/A
Completed NCT02984098 - 40% Orally Administered Dextrose Gel is More Effective Than 25% Dextrose Phase 4
Completed NCT02380989 - Integrative Ayurveda Healing Relieves Minor Sports Injury Pain Phase 2
Completed NCT02489630 - Low Dose Ketamine as an Adjunct to Opiates for Acute Pain in the Emergency Department Phase 4
Completed NCT03107338 - Preventive Treatment of Pain After Dental Implant Surgery Phase 4
Completed NCT02817477 - Intranasal Ketamine for Acute Traumatic Pain Phase 4