Clinical Trials Logo

Clinical Trial Summary

The aim of this study is to investigate any direct correlation between increased intrathoracic pressure, intraabdominal pressure and intracranial pressure, following a controlled elevation in intraabdominal pressure and intrathoracic pressure (PEEP). The second end-point is to investigate any correlation between elevated intracranial pressure and vasopressin release, urine output and urine and serum osmolality by measuring their values at different time-points.


Clinical Trial Description

Increase in intraabdominal pressure (IAP) has been demonstrated to correlate with consequential hemodynamic effects. Several studies have been carried out mostly in experimental settings to define the underlying mechanisms that regulate the pathophysiology following an increase in IAP. In the last years this topic has become concerning because of the wide spread of laparoscopy, that is namely an iatrogenic acute increase in IAP. Patients selected and consented for elective surgery will undergo standard of care and additional measurements during and after surgery. The measurements will be done at different stages of laparoscopic surgery. 1. A) Baseline, patient under general anesthesia, Foley catheter positioned, beginning urine collection, before insufflation of pneumoperitoneum 2. B) 10-15 minutes after insufflation of pneumoperitoneum at 15mmHg, PEEP at 5cmH2O or lowest setting 3. C) 10-15 minutes after stabilization of PEEP at 10cmH2O, pneumoperitoneum still at 15 mmHg 4. D) 10-15 minutes after desufflation of pneumoperitoneum and basal mechanical ventilation Measurements include : - Intraabdominal pressure IAP: assessed via laparoscopic insufflator, set at 15 mmHg as a standard value for all laparoscopic procedures - Intrathoracic pressure: indirectly measured by variability of peak expiratory pressures - Urine collection: through a Foley catheter from the beginning of surgery to post-operative day 1 - Urine osmolality (to be assessed at set time-points ) - Hourly urine output (at least 24 hours in order to evaluate expected significant variation even after the procedure end, since renal adaptation could take longer period) - Serum/plasma collection : blood draws to evaluate specific values of - Plasma Vasopressin (ADH) - Serum osmolality - Mean arterial pressure : standard of care - Pulmonary expiratory end-pressure (PEEP): anesthesiologists routinely adapt PEEP in order to maintain an optimal ventilation, especially in obese patients and during laparoscopy - Optic nerve sheath diameter (ONSD): a 7.5-MHz linear ultrasound probe to measure the diameter of the optic nerve sheath 3 mm behind the globe is going to be used; a trained study personnel physician will take the non-invasive sonographic picture using ultrasound. The ONSD will be measured from the captured picture. Study personnel will record the interaction on the patient's chart and include the measurement on the database ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03707054
Study type Interventional
Source The Cleveland Clinic
Contact
Status Active, not recruiting
Phase N/A
Start date April 28, 2017
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Not yet recruiting NCT03227354 - Validation of Non-invasive Absolute Intracranial Pressure Monitoring N/A
Completed NCT03641443 - non_invasive_aICP_Tumor N/A
Completed NCT06451289 - Study on Optic Nerve Sheath Diameter Measurements in Prolonged Pediatric Seizures
Not yet recruiting NCT03828032 - Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients. N/A
Terminated NCT03286426 - Ocular Screening in Children and Young Adults at Risk for Increased Intracranial Pressure N/A
Completed NCT03782077 - Change of Optic Nerve Sheath Diameter After Deflation of Pneumatic Tourniquet
Recruiting NCT06288659 - aSAH Treatment Based on Intraventricular ICP Monitoring: A Prospective, Multicenter, Randomized and Controlled Trial N/A
Not yet recruiting NCT06428461 - Evaluation of Supraclavicular Brachial Plexus Blocks at Various Volumes: Impact on Optic Nerve Sheath Diameter N/A
Completed NCT03195881 - Neuroprognostication Using Optic Nerve Sheath Diameter
Completed NCT04446013 - Comparison of ONSD and rSO2 Measurements Between General and Spinal Anesthesia in C-Section N/A
Completed NCT03418753 - Non-invasive Diagnostic for Assessing Elevated Intracranial Pressure
Recruiting NCT06403592 - The Effect of a Laryngeal Mask Airway on Optic Nerve Sheath Diameter
Active, not recruiting NCT05609071 - Technology of Intracranial Pressure Estimation by Single-Channel EEG in Brain Disease
Completed NCT05286697 - The Effect of Optic Nerve Diameter on Postoperative Cognitive Function in Laparoscopic Hysterectomy N/A
Completed NCT06048900 - Evaluation of the Effect of Trendelenburg Position Duration on Intracranial Pressure N/A
Active, not recruiting NCT05731765 - SVP Detection Using Machine Learning
Recruiting NCT05346471 - Infra- and Supratentorial Neuromonitoring N/A
Recruiting NCT06464419 - Effect of Lithotomy Position on Optic Nerve Sheath Diameter
Recruiting NCT03344432 - Correlation Intraocular Pressure With Intracranial Pressure N/A
Recruiting NCT05931991 - Intra-operative Evaluation of the External Ventricular Drain Catheter Position With Structured Light for Patients (Bullseye EVD)