Abdominal Cancer Clinical Trial
Official title:
Investigating the Improvement in 4D CT Images Using Audiovisual Biofeedback: An Intra-fraction and an Inter-fraction Evaluation.
This study will look at how tumors in the chest and abdomen move when you breathe. Your
doctors are studying if extra 4D CT scans and instructions on how to breathe can help predict
this type of movement and improve the accuracy of radiation treatment. 4D CT scans are
approved by the FDA. A 4D CT scan is different from a regular CT because it moves slower and
takes more pictures. It takes pictures of the way your body moves when you breathe. This
gives doctors more pictures of your body so that they can match your pictures to the way you
breathe.
In this study, instructions on how to breathe will be visual and audio. Visual instructions
will be given to you on a computer screen. You will hear audio instructions through a
speaker.
JUSTIFICATION Among the various sites affected by cancer, statistics show that lung cancer is
the leading cause of death among both men and women. One major reason for this is that the
treatment of lung cancer has not improved drastically in the past few years. Lung tumors are
also potentially difficult to treat with radiation therapy due the patients' respiration
motion causing the tumor to be mobile.
A1) Detrimental effects of respiration motion Respiration motion affects all tumor sites in
the thorax and abdomen, although the disease of most prevalence and relevance for
radiotherapy is lung cancer. Many studies have been performed to study lung-tumor motion and
methods to compensate for this motion during radiation treatment imaging, planning and
delivery. The significance of the respiration motion compensation techniques is to reduce the
mobility of the tumors and thereby reduce the dose to the surrounding normal structures. If
no motion compensation methods are used then a margin must be added to ensure adequate
coverage of the tumor. Large margins results in radiation delivered to a larger volume of
critical structures.
A2) Compensation techniques Methods that reduce respiration induced intrafraction motion
include active breathing control, voluntary breath-hold, deep inspiration breath-hold,
respiratory gated techniques, and 4D or tumor-tracking techniques.1-6 Active breathing
control and the deep inspiration breath hold involves the patient holding their breath. While
these may improve the reproducibility of the position of the tumor within the lung, it is not
feasible for all patients especially those that have a compromised respiratory function.
Respiratory gating techniques involves turning on the beam during only a small window of the
respiratory cycle. Thus respiratory gating reduces the intrafraction motion but does not
totally eliminate it. During respiratory gating, since the beam is turned on and off based on
the respiration signal, the treatment time may increase up to 35-40% compared to a regular
treatment. Since the patient has to spend more time on the table, this could introduce more
errors due to patient movement on the table. 4D or tumor tracking techniques has it own share
of issues as is discussed in the following paragraph.
A3) During 4D radiotherapy (4DRT) delivery the tumor is continuously tracked with the
radiation beam as they move throughout the respiratory cycle. The benefits of 4DRT are a
reduction in dose to the healthy lung tissue and/or an increase in dose to the tumor. The
gains from 4DRT are clinically measurable, though much development is needed in the various
steps of 4DRT i.e. CT image acquisition, planning and delivery.
During 4D CT image acquisition, images are acquired during different respiration states of
normal breathing.7-9 The quality of images acquired by using the 4D CT image acquisition is
limited by patients respiration pattern. Since the images are sorted based on the patients
respiration motion, any change in pattern could lead to the images being sorted to a
different part of respiration. This effect is reflected as an artifact on the CT image.
Target volumes along with respiration motion can be determined by contouring the target in
the various respiratory states thus obtaining a volume that encompasses an entire breathing
cycle. The efficacy and accuracy of 4D CT will be maximized when patients breathe
reproducibly. However it is well-known that respiration motion varies not only from one day
to the next but also during one fraction.
A4) Effect of irregular breathing For 4D CT, minimizing the variation of patient breathing
within a treatment fraction and from fraction to fraction, i.e., increasing the
reproducibility of patient breathing, is important. Large variation in patient respiration
motion and irregular breathing lead to artifacts in the CT images as shown in. However,
respiration motion amplitude and period vary with time and from patient to patient because of
various anatomic and physiologic factors.
A5) Possible solutions Biofeedback/coaching techniques are being increasingly embedded in the
behavioral treatment of patients with lung disease such as chronic obstructive pulmonary
disease, asthma, and cystic fibrosis. For respiratory gating, several studies suggest that
verbal prompts improve respiration reproducibility. Kini et al.12 concluded that audio
prompts improve the stability of respiration frequency of the patient but does not maintain
the range of respiratory motion, whereas visual prompts control only the regularity of the
displacement and the frequency is not reproducible. Based on the results of Kini et al.12,
combined audio-visual biofeedback was devised to improve the reproducibility of respiration
motion. Recently Neicu et al.13 described results of audio and visual prompting and
demonstrated improvement in the efficacy of so-called synchronized moving aperture radiation
therapy, using respiratory traces from single-patient and volunteer sessions.
George et al.14 concluded based on a 24-patient, multisession study that audio-visual
biofeedback can significantly reduce residual motion variability for a given duty cycle, thus
potentially improving the accuracy of respiratory-gating. From the results of this study it
was seen that audio-visual biofeedback reduced motion by 0.5 cm (0.29 to 0.24 cm) for exhale
breathing and 1.5 cm (0.46 to 0.36 cm) for inhale breathing.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03144622 -
18F-FSPG PET/CT Imaging in Patients With Cancers
|
||
Completed |
NCT04553471 -
Palliative Lattice Stereotactic Body Radiotherapy (SBRT) for Patients With Sarcoma, Thoracic, Abdominal, and Pelvic Cancers
|
N/A | |
Completed |
NCT02566096 -
Efficacy of Transverses Abdominis -Plane Block With Bupivacaine Versus Bupivacaine With Morphine Postoperatively
|
Phase 4 | |
Recruiting |
NCT05533424 -
Ultrasound Guided Quadratus Lumborum Block Versus Transversus Abdominis Plane Block as Postoperative Analgesia in Patients Undergoing Abdominal Cancer Surgery.
|
Phase 3 | |
Completed |
NCT04729634 -
Survey Of Mobilisation and Breathing Exercises After Thoracic and Abdominal Surgery
|
N/A | |
Recruiting |
NCT00493688 -
A Study to Determine Whether Perioperative Energy Dynamics Correlates With Postoperative Outcomes
|
||
Completed |
NCT04152564 -
Cardio-pulmonary and Analgesic Effects of Pre-peritoneal VS Epidural Infusion of L-bupivacaine on Abd. Cancer Patients
|
N/A | |
Completed |
NCT03555266 -
NSS-2 BRIDGE Device in Post-Operative Pain Management
|
N/A | |
Withdrawn |
NCT04114422 -
A Seven-day Preoperative Exercise Training Program in People With Abdominal Cancer
|
N/A | |
Terminated |
NCT04199754 -
IV Contrast-Enhanced Cone Beam Computed Tomography (CBCT) in Radiotherapy
|
Early Phase 1 | |
Recruiting |
NCT03063112 -
Radiofrequency and Chemical Neurolysis of Thoracic Splanchnic Nerve for Abdominal Cancer Pain
|
N/A | |
Completed |
NCT02998736 -
Trial of Perioperative Tadalafil and Influenza Vaccination in Cancer Patients Undergoing Major Surgical Resection of a Primary Abdominal Malignancy
|
Phase 1 | |
Completed |
NCT00415675 -
Respiratory Tumor and Normal Tissue Motion
|
N/A | |
Not yet recruiting |
NCT05903430 -
A Feasibility Study of MRI Guided Stereotactic Ablative Radiotherapy (MIDSECTION)
|
||
Completed |
NCT03751384 -
Improvement of Compliance for High Doses of EPA Amongst Patients With Colorectal Cancer
|
N/A | |
Recruiting |
NCT05219058 -
Reconstruction in Extended MArgin Cancer Surgery
|
||
Completed |
NCT03102619 -
Wireless Assessment of Respiratory and Circulatory Distress; A Pilot Study
|
N/A | |
Not yet recruiting |
NCT06265948 -
Comparsion Between Intravenous Infusion of Ketofol and Inhalational Anasthetics in Abdominal Cancer Surgeries for Post Operative Analgesia
|
||
Completed |
NCT05524454 -
Evaluation of a Cone-beam CT Scanner for Image Guided Radiotherapy
|
N/A | |
Completed |
NCT04316871 -
Dosage of Epidural Morphine in Elderly Patients
|
Phase 4 |