Clinical Trials Logo

Clinical Trial Summary

Automated carbon dioxide (CO2) angiography is considered a safe diagnostic alternative to standard iodinated contrast medium (ICM) for endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA), especially in patients with preoperative renal function impairment. Recent literature experiences describe the use of automated CO2 angiography in EVAR. One of the main issues of CO2 angiography is the inability to detect the origin of the lowest renal artery (proximal neck visualization) that was estimated up to 38%. In these experiences, the CO2 automated angiography is usually performed by a 5F pigtail catheter placed at renal arteries level. The aim of the study is to evaluate the efficacy of a new automated CO2 injection technique by a 5F introducer (single hole catheter) positioned at the distal level of the proximal neck in detecting both renal arteries in the first diagnostic and completion angiographies.


Clinical Trial Description

Endovascular aneurysm repair is currently a wide spread therapeutic option due to a lower 30-day morbidity/mortality compared with open repair (OR), especially in patients with high surgical risk. The routinary EVAR technique requires the use of iodinated contrast medium (ICM) which can cause contrast induced-acute kidney injure (CI-AKI). The incidence of CI-AKI after EVAR is estimated between 2% and 16% although renal insult can also be caused by microembolization, unplanned renal (or polar) artery coverage, renal artery lesion (as dissection) or post-operative inflammatory reaction. In the past few years, several studies pointed out the importance of reducing the amount of iodinated contrast medium injected and proposed carbon dioxide (CO2) as an alternative to partially or completely replace ICM, especially in patients with preoperative chronic renal impairment. According with the literature, manual or automatic CO2 injection provides a good quality imaging of both proximal and distal sealing zone in standard EVAR procedures and, combined with fusion imaging, allows to perform juxta and pararenal abdominal aortic aneurysm repair with fenestrated endograft reducing the total amount of ICM required to the procedure. The most relevant limit to the use of CO2 is the inability to identify the proximal landing zone and the lowest renal artery that occurs in a significant number of cases (38.7%). This limit could be related to the physical property of CO2 because, differently from ICM, it is a gas that does not completely fill the aortic lumen but it floats in the anterior portion of the aneurysmatic sac and does not allow the detection of renal arteries with a posterior origin. The automated CO2 injection is commonly performed using a pigtail catheter (5F/65mm length) placed at the renal arteries level. The primary end point of the study is to identify an alternative and effective method of CO2 injection, using an automatic system through the digital Angiodroid injection system (Angiodroid Srl, San Lazzaro, Bologna) connected to a 5F introducer placed at the distal portion of infra-renal neck that allows the identification of the lowest renal artery. This is a prospective, single center, observational, case-control study, in which each patient is the control of himself because during the procedure 2 angiographic CO2 techniques (angiography by pig tail vs 5 F introducer) are performed and compared. All patients underwent a preoperative computed tomography angiography (CTA) within 3 months before the procedure. The images are analyzed using a dedicated software for vessel analysis (3Mensio TM, Vascular Imaging Bilthover, Netherlands) and the AAA volume is calculated using the same software by selecting points of the external aortic wall and internal aortic lumen from the lower renal artery to the aortic bifurcation. The level of renal arteries and aortic bifurcation are evaluated on preoperative CTA reconstructions and matched with vertebral bone landmarks. At the beginning of the procedure two CO2 DSA will be performed: the first one through the pigtail placed at the level of renal arteries and the second one through a 5F introducer placed at the end of the proximal sealing zone in order to identify the lowest renal artery and compare the quality of the images obtained. The same way, at the end of the procedure after the endograft deployment, two CO2 DSA will be performed: the first one through the pigtail catheter placed at the level of renal arteries and the second one through the 5F introducer placed at the level of the contralateral iliac limb. The investigators prospectively collect clinical and morphological preoperative, intraoperative and postoperative data as shown in the table above. Clinical characteristics: age years, sex, hypertension (systolic blood pressure ≥140 or/and diastolic ≥90 mmHg, or specific therapy), dyslipidemia (total cholesterol ≥200 mg/dl or low density lipoprotein ≥120 mg/dl or specific therapy), diabetes mellitus (pre-diagnosed in therapy with oral hypoglycemic drugs or with insulin), current smoking, coronary artery disease (defined as a history of angina pectoris, myocardial infarction or coronary revascularization), chronic obstructive pulmonary disease (defined as chronic bronchitis or emphysema), chronic kidney disease (glomerular filtration rate <60 ml/min), dialysis, pre and post-operative creatinine serum, ASA (American Society Anesthesiologic classification), medical therapy (antiplatelet types, anticoagulant therapy, statin therapy, anti-hypertensive medical therapy). Morphological characteristics: aneurysm diameter, aneurysm volume, aneurysm neck features according to Chaickof classification, iliac axes features according to Chaickof classification, renal arteries number and clock position, hypogastric arteries patency, aortic carrefour diameter. Intraoperative data: anesthesia (general or spinal), vascular access (surgical or percutaneous), endograft features (bi- or tri-modular, suprarenal fixation, proximal diameter of the endograft, left and right iliac limb diameter, embolization of the aneurysmatic sac, coils number, hypogastric embolization or coverage, other adjunctive maneuvers as iliac axes stenting), type and amount of contrast medium, fluoroscopy time, dose area product (DAP) (fluoroscopy DAP, DSA DAP and total DAP), renal arteries detection at the beginning of the procedure with CO2 DSA from 5F pigtail and 5F introducer, renal and hypogastric arteries and endoleaks detection at the end of the procedure with CO2 DSA from 5F pigtail and 5F introducer (as explained before). Post-operative data: complications related to CO2 injection rate (nausea, vomit, abdominal pain, hypotension), endoleaks at the discharge, perioperative mortality, 30-days mortality, 30-days medical or surgical complications, 30-days reintervention rate, 30-days renal function. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05304026
Study type Observational
Source University of Bologna
Contact Enrico Gallitto, MD, PhD
Phone +390512143288
Email enrico.gallitto@gmail.com
Status Recruiting
Phase
Start date January 1, 2021
Completion date September 15, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04227054 - Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks N/A
Active, not recruiting NCT03687489 - Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System N/A
Active, not recruiting NCT03507413 - Metformin Therapy in Non-diabetic AAA Patients Phase 2/Phase 3
Not yet recruiting NCT05756283 - The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair N/A
Not yet recruiting NCT04089241 - Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair N/A
Active, not recruiting NCT02604303 - A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
Terminated NCT01843335 - Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair N/A
Completed NCT02224794 - LIFE Study: Least Invasive Fast-Track EVAR
Terminated NCT02469376 - Evaluation of a New Imagingtechnologie for Thrombosis Phase 1
Completed NCT02229006 - Sodium Fluoride Imaging of Abdominal Aortic Aneurysms N/A
Completed NCT01118520 - AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) Phase 2
Terminated NCT01425242 - Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension N/A
Completed NCT00746122 - Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair N/A
Completed NCT03952780 - Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
Completed NCT00583414 - Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients N/A
Recruiting NCT05864560 - Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
Completed NCT01683084 - Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms Phase 4
Active, not recruiting NCT03180996 - Global Fenestrated Anaconda Clinical sTudy
Completed NCT02493296 - The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
Completed NCT03320408 - Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers