Clinical Trials Logo

Clinical Trial Summary

Abdominal aortic aneurysm (AAA) is a common vascular disease and associated with risk of rupture, but also with a high cardiovascular (CV) event rate. A key difficulty in AAA is predicting these life-threatening complications, which are strongly linked to vascular health. In 2013, the SMART risk score was developed to calculate the risk of the patients for recurrent vascular events based on clinical characteristics. Recently, a novel, easy to perform, non-invasive test of endothelial function (the carotid artery reactivity (CAR) test), reflecting target organ damage, has been introduced. The CAR is a simple, quick (5-min), non-invasive test that uses ultrasound to examine the carotid artery in response to sympathetic stimulation by placing one hand in cold water. This test shows strong agreement with both coronary and aortic responses to sympathetic stimulation and predicted CV-events in patients with peripheral arterial disease. The aim of this prospective 2-year follow-up study is to investigate the predictive capacity of the CAR-test for development of CV-events after elective AAA repair in comparison to the SMART risk score. Secondary objectives are to investigate the predictive capacity of arterial stiffness measurements and the post-operative CAR-test for development of CV-events and to evaluate health status scores to provide insight if these scores can support clinical decision making.


Clinical Trial Description

The investigators will include 194 patients with an AAA who will be scheduled for repair. Participants will be recruited from all collaborating hospitals (currently Radboudumc, Rijnstate, CWZ) after providing written informed consent. In this observational, prospective study, a total of 194 patients who are going to be treated for their AAA will be included. Baseline patient characteristics will be registered, including traditional risk factors and CV-history. In addition to regular care of measuring AAA diameter progression (in mm/year), we will perform the CAR-test (10-min) and non-invasive arterial stiffness measures (PWA and PWV) with the SphygmoCor device (10-min). Furthermore, the investigators will ask patients to complete a questionnaire about the quality of their life. A second questionnaire tries to clarify the disease experience of the patients. Both questionnaires will be asked to be completed at the start, 6-8 weeks after repair, after one year and after two years of repair. Subsequently, the investigators will record major adverse cardiovascular events (MACE) according to the International Classification of Disease-10. Registration of MACE will be performed using hospital-records and following international guidelines. Across a 2-year follow-up, by means of regular follow-up appointments, the investigators will examine the ability of the CAR parameter and arterial stiffness parameters to predict CV-events. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04183426
Study type Observational
Source Rijnstate Hospital
Contact Michel Reijnen, MD, prof
Phone 0880057282
Email MReijnen@rijnstate.nl
Status Recruiting
Phase
Start date June 12, 2020
Completion date June 2027

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04227054 - Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks N/A
Active, not recruiting NCT03687489 - Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System N/A
Active, not recruiting NCT03507413 - Metformin Therapy in Non-diabetic AAA Patients Phase 2/Phase 3
Not yet recruiting NCT05756283 - The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair N/A
Not yet recruiting NCT04089241 - Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair N/A
Active, not recruiting NCT02604303 - A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
Terminated NCT02469376 - Evaluation of a New Imagingtechnologie for Thrombosis Phase 1
Completed NCT02229006 - Sodium Fluoride Imaging of Abdominal Aortic Aneurysms N/A
Completed NCT02224794 - LIFE Study: Least Invasive Fast-Track EVAR
Terminated NCT01843335 - Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair N/A
Completed NCT01118520 - AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) Phase 2
Terminated NCT01425242 - Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension N/A
Completed NCT00746122 - Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair N/A
Completed NCT03952780 - Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
Completed NCT00583414 - Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients N/A
Recruiting NCT05864560 - Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
Completed NCT01683084 - Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms Phase 4
Active, not recruiting NCT03180996 - Global Fenestrated Anaconda Clinical sTudy
Completed NCT02493296 - The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
Completed NCT03320408 - Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers