Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01097772
Other study ID # 771-0004
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date March 2010
Est. completion date September 16, 2015

Study information

Verified date June 2021
Source Endologix
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System


Description:

A prospective, consecutively enrolling, non-randomized multi center clinical evaluation of the safety and performance of the TriVascular AAA Stent Graft when used in the treatment of patients with Abdominal Aortic Aneurysms (AAA).


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date September 16, 2015
Est. primary completion date October 29, 2010
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Patient is > 18 years of age 2. Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study) 3. Patient has signed an Ethics Committee (EC) approved Informed Consent Form 4. Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year. 5. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following: - Abdominal aortic aneurysm =5.0 cm in diameter - Aneurysm has increased in size by 0.5 cm in last 6 months. - Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent non-aneurysmal aortic segment 6. Patient has patent iliac or femoral arteries that allow endovascular access with the TriVascular AAA device. 7. Patient has a suitable non-aneurysmal proximal aortic neck length of = 7 mm inferior to the most distal renal artery ostium. 8. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of =10 mm. The resultant repair should preserve patency in at least one hypogastric artery. 9. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm. 10. Patient has suitable non-aneurysmal distal iliac luminal diameters between 8 and 20 mm. 11. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm. 12. Patient has juxtarenal aortic neck angulation = 60º if proximal neck is =10 mm and = 45º if proximal neck is <10 mm. 13. Patient must be willing to comply with all required follow-up exams. Exclusion Criteria: 1. Patient has a dissecting aneurysm 2. Patient has an acutely ruptured aneurysm 3. Patient has an acute vascular injury 4. Patient has a need for emergent surgery 5. Patient has a known thoracic aortic aneurysm or dissection. 6. Patient has a mycotic aneurysm or has an active systemic infection 7. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina) 8. Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months. 9. Patient has a major surgical or interventional procedure planned =30 days of the AAA repair. 10. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome). 11. Patient has history of bleeding disorders or refuses blood transfusions. 12. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl 13. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment. 14. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers or nitinol. 15. Patient has a body habitus that would inhibit X-ray visualization of the aorta 16. Patient has a limited life expectancy of less than 1 year 17. Patient is currently participating in another investigational device or drug clinical trial 18. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Study Design


Intervention

Device:
Implant of Ovation Abdominal Stent Graft System
Single occurrence permanent implant of AAA device.

Locations

Country Name City State
Germany Herz- und Gefässzentrum Bad Bevensen Bad Bevensen
Germany Klinikum Dortmund GmbH Dortmund
Germany Cardiovascular Center Frankfurt-Sankt Katherinen Frankfurt
Germany Universitäres Herz und Gefäß Zentrum Hamburg Hamburg
Germany Univeristy Klinik Köln Köln
Germany Herzzentrum Leipzig Leipzig
Germany St Franziskus Hospital Munster Münster

Sponsors (1)

Lead Sponsor Collaborator
TriVascular, Inc.

Country where clinical trial is conducted

Germany, 

Outcome

Type Measure Description Time frame Safety issue
Primary The primary safety endpoint is defined as the proportion of subjects who experience a Serious Adverse Event within 30 days of the initial procedure. The safety of the TriVascular AAA Stent Graft will be determined by comparing the rate of Serious Adverse Events in the Treatment Group against the rate of Serious Adverse Events in the Control Group within 30 days of the initial procedure. 30-Days
Secondary To evaluate the performance of the TriVascular AAA Stent-Graft System within 30 days of the initial procedure. The performance of the TriVascular AAA Stent-Graft System will be determined by comparing the composite success rate in the Treatment Group against an estimated success rate of 80% in the Control Group within 30 days of the initial procedure. The composite success rate is defined as:
Technical Success, defined as successful delivery and deployment of one aortic body and two iliac limbs.
Absence of Type I and III endoleaks
Absence of Rupture
Absence of Conversion to Open Surgical Repair
Freedom from mortality
30-Days
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04227054 - Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks N/A
Active, not recruiting NCT03687489 - Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System N/A
Active, not recruiting NCT03507413 - Metformin Therapy in Non-diabetic AAA Patients Phase 2/Phase 3
Not yet recruiting NCT05756283 - The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair N/A
Not yet recruiting NCT04089241 - Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair N/A
Active, not recruiting NCT02604303 - A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
Completed NCT02229006 - Sodium Fluoride Imaging of Abdominal Aortic Aneurysms N/A
Terminated NCT01843335 - Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair N/A
Terminated NCT02469376 - Evaluation of a New Imagingtechnologie for Thrombosis Phase 1
Completed NCT02224794 - LIFE Study: Least Invasive Fast-Track EVAR
Terminated NCT01425242 - Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension N/A
Completed NCT01118520 - AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) Phase 2
Completed NCT00746122 - Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair N/A
Completed NCT03952780 - Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
Completed NCT00583414 - Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients N/A
Recruiting NCT05864560 - Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
Completed NCT01683084 - Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms Phase 4
Active, not recruiting NCT03180996 - Global Fenestrated Anaconda Clinical sTudy
Completed NCT02493296 - The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
Completed NCT03320408 - Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers

External Links