Clinical Trial Summary

The purpose of the study is to evaluate the TALENT endoluminal stent-graft system in patients with abdominal aortic aneurysms. The TALENT endoluminal stent-graft system is a flexible, implantable endoluminal vascular device preloaded in a placement system that is used to exclude abdominal aortic aneurysms.


Clinical Trial Description

An aneurysm is a localized dilatation of a blood vessel at least 1 1/2 to 2 times the normal vessel diameter. Abdominal aortic aneurysms are relatively common, and have been detected in 1.3% to 2.7% of patients 65 to 80 years of age (Blum, et al, 1996; Collins, Araujo, and Lindsell, 1988; Scott, Ashton, and Kay, 1991). A large proportion (up to 50%) of patients with untreated AAAs experience rupture and exsanguination (Johansen, 1995). Ruptured AAAs are the 13th leading cause of death in the US, accounting for more than 15,000 deaths per year (Cronenwett and Sampson, 1995).

Conventional treatment of abdominal aortic aneurysms is by a surgical procedure involving midline laparotomy, aortic clamping, aortic bypass, and blood loss with associated transfusion. Improvements in surgical techniques and patient care have allowed the mortality rate associated with this procedure to be reduced to approximately 5%, when elective repair is done prior to rupture of the aneurysm. Risks of surgery increase when the patient is considered to be a poor candidate for surgery.

Due to progress made in interventional radiology and endovascular surgery, it is now possible to treat aneurysms without an abdominal surgical procedure, thus potentially further reducing the risks associated with elective repair. This new therapeutic approach consists of transfemoral introduction of a metallic stent coupled with a vascular graft. When the stent device is deployed and expanded within the aneurysmal blood vessel, it creates a new aortic lumen for blood flow, effectively excluding the aneurysm sac from the flow while maintaining perfusion to the lower limbs. This less invasive technique is designed to prevent the need for laparotomy, to reduce the need for blood transfusions, to decrease the use of anesthetics and other drugs, and to speed recovery time.

The objective of this study is to evaluate the safety and effectiveness of the TALENT endoluminal stent-graft system in patients who may be categorized as standard risk, high risk or other indications. Standard risk patients are patients with indications for treatment that are consistent with those for a manufacturer IDE, when there is no active enrollment in the IDE. High risk patients are patients who do not meet the entrance criteria for the manufacturer sponsored IDE as they are at high risk of morbidity and mortality with standard surgical repair. Other indications would be considered patients with indications for treatment outside of those or the manufacturer sponsored IDE.

This study will be performed in both high risk and low risk patients who are considered good candidates for endoluminal repair of abdominal aortic aneurysms. Patients should be heparinized during the implant procedure such that an activated clotting time of 300 seconds is achieved. During implantation of the TALENT endoluminal stent-graft, the pre-implant CT scan and available angiograms are used together with (on-the-table) digital subtraction angiography (DSA), roadmapping, and angiography for proper implant positioning. The TALENT endoluminal stent-graft endoprosthesis is inserted by delivery catheter and introducer sheath via a surgical cutdown (e.g., external iliac artery, femoral artery) approach. The introducer sheath and delivery catheter containing the stent-graft is inserted over a guidewire and advanced into the aorta and above the aneurysm. With the delivery catheter in the correct position, the push rod is held stationary while the outer sheath is slowly withdrawn. The introducer sheath is then withdrawn further until the stent-graft is completely deployed. The balloon may be inflated along the full length of the implanted device to model the springs against the vessel wall and to unravel possible wrinkles in the graft fabric. After deployment of the stent-graft, angiography is performed to verify implant position and to check for the presence of endoleaks.

Subjects will undergo an evaluation of the TALENT endoluminal stent-graft to determine the safety and efficacy of the device as indicated by the adverse event rate, and to determine the risk factors that are most predictive of a successful outcome when used to exclude abdominal aortic aneurysms that require suprarenal fixation in high risk and low risk patients. Follow-up will be completed at 1, 6, 12, 24, 36, 48, and 60 months. Subject evaluation at 1 month will include a complete Physical Examination, Bilateral ABIs, and a Duplex Ultrasound (if not previously completed at time of discharge). Subject evaluation at 6 months will also include a Complete Physical Examination, Bilateral ABIs, Duplex Ultrasound, and Abdominal X-ray (AP, Lateral, 2 Obliques). Subject evaluation at 12, 24, 36, 48, and 60 months will include a Complete Physical Examination, Bilateral ABIs, Abdominal X-ray (AP, Lateral, 2 Obliques), and Spiral CT scan with and without IV Contrast 2.5mm. ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00549432
Study type Interventional
Source Arizona Heart Institute
Contact
Status Active, not recruiting
Phase N/A
Start date October 2002
Completion date October 2012

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04227054 - Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks N/A
Active, not recruiting NCT03687489 - Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System N/A
Active, not recruiting NCT03507413 - Metformin Therapy in Non-diabetic AAA Patients Phase 2/Phase 3
Not yet recruiting NCT05756283 - The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair N/A
Not yet recruiting NCT04089241 - Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair N/A
Active, not recruiting NCT02604303 - A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
Completed NCT02224794 - LIFE Study: Least Invasive Fast-Track EVAR
Terminated NCT02469376 - Evaluation of a New Imagingtechnologie for Thrombosis Phase 1
Completed NCT02229006 - Sodium Fluoride Imaging of Abdominal Aortic Aneurysms N/A
Terminated NCT01843335 - Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair N/A
Completed NCT01118520 - AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) Phase 2
Terminated NCT01425242 - Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension N/A
Completed NCT00746122 - Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair N/A
Completed NCT03952780 - Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
Completed NCT00583414 - Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients N/A
Recruiting NCT05864560 - Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
Completed NCT01683084 - Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms Phase 4
Active, not recruiting NCT03180996 - Global Fenestrated Anaconda Clinical sTudy
Completed NCT02493296 - The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
Completed NCT03320408 - Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers