Clinical Trials Logo

Clinical Trial Summary

The incidence of isolated common iliac artery (CIA) aneurysms is low, but in combination with an abdominal aortic aneurysm (AAA) they are found in approximately 20-40% of cases. Basically, two different endovascular strategies can be applied to treat a CIA aneurysm with, including 1. the coverage and 2. the preservation of blood flow to the internal iliac artery (IIA). Coil and coverage of the IIA is related to ischemic complications, including buttock claudication, erectile dysfunction and the more severe spinal and colonic ischemia. Iliac branched devices (IBD) have been developed to exclude CIA aneurysms preserving the IIA and currently three alternatives are on the market. Clinical results of these devices are promising but loss of patency is not uncommon. The major difference between the two devices is the IIA component. The Cook IBD uses a -non-dedicated IIA component, while in the GORE® EXCLUDER® Iliac Branch Endoprosthesis (Gore IBE device) a dedicated self expanding stent is used. Stresses and forces exerted onto the endograft by aortic pulsatility may have an effect on the durability and functioning of the endograft. Intermittent hinchpoints could also have an effect on stent integrity and stenosis. By evaluating endograft movement during the cardiac cycle (ECG-gated CTA) it is possible to assess the stress and force exerted onto the endograft. This might help gain insight into mechanisms underlying potential endograft failure, and aid procedural planning and the development of future devices with long-term durability. The choice for device is not part of this study.


Clinical Trial Description

Objectives:To compare the mobility of the hypogastic artery during the cardiac cycle before and six weeks after implantation of the Gore IBE device in conjunction with its dedicated self expandable Internal Iliac component (Sub-study A);and to quantitatively characterize the displacement of stents with regard to the main body and native IIA during the cardiac cycle on an implanted iliac branched endograft in conjunction with a non-dedicated IIA component (Cook IBD with Advanta V12 or Fluency) with those in conjunction with a dedicated self expandable Internal Iliac component (Gore IBE device). (Sub-study B) Study design: Sub-study A & B: Multicenter observational case studies Study population: Sub-study A: 15 prospectively included patients and sub-study B: 15 patients in each group that have been treated in the period October 2006 - July 2016. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03762525
Study type Interventional
Source Rijnstate Hospital
Contact
Status Completed
Phase N/A
Start date October 5, 2016
Completion date December 31, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT03369886 - The Relationship Between Macular OCTA and GCIPL and Their Combinational Index Using AI N/A
Completed NCT02837744 - Studying Hemostatic Effect of Axiostat® Dressing on Radial Access After Percutaneous Procedure
Completed NCT05588232 - the Effectiveness of Therapeutic Virtual Reality Versus Pharmacological Sedation on Pain and Anxiety During Interventional Cardiology Procedures N/A
Recruiting NCT03574636 - OCT vs IVUS vs QCA to Guide Moderate-to-severe Calcified Lesion Stent Implantation N/A
Recruiting NCT04876222 - Direct or Subacute Coronary Angiography in Patients With Out of Hospital Cardiac Arrest Without Coma. N/A
Completed NCT01100476 - Mynx M5 One Hour Ambulation Study Phase 4
Completed NCT04316754 - Effectiveness of Music During Cardiac Catheterization N/A
Completed NCT03645902 - Comparison Between TOF and SWAN Sequences in the Detection of Arterial Occlusion in Acute Ischemic Stroke Using MRI
Recruiting NCT05417022 - Safety and Efficacy Evaluation of Orbital Atherectomy System in de Novo Calcified Lesions
Completed NCT02840903 - A Non-interventional Study to Observe the Computed Tomographic Angiography Image Quality With Different Contrast Media Injection Protocols Under Different Computed Tomography Machines Parameters Setting
Recruiting NCT03778645 - Adrenal Venous Sampling Via an Antecubital Approach
Recruiting NCT03821753 - The Effect of the Glycemic Variability on Macular Retinal Microcirculation and Cognitive Functions in Patient With Type 1 Diabetes
Terminated NCT00732628 - Evaluating Outcomes in the Placement of Boomerang Percutaneous Device N/A
Terminated NCT03060460 - Ultrasound Guided Insertion of Sheath Before Angiography or Angioplasty N/A
Not yet recruiting NCT05511675 - The Effect of Cold Application on the Hemostasis, Extremity Pain And Terumo Band Usage After Transradial Angiography N/A