Clinical Trials Logo

Clinical Trial Summary

Cardiac output (CO) monitoring is of primary importance in high-risk surgery and critically ill patients. Intermittent thermodilution (ThD) by means of a pulmonary artery catheter (PAC) was invasiveness, the occurrence of complications, and inability to estimate CO on a beat-by-beat basis may explain the reduction in routine use. Echocardiography is now widely used. However, a poor acoustic window, inaccurate diameter calculations, and difficulty maintaining the angle of insonation and blood flow within the recommended values may lead to inaccuracy in CO estimation.Pulse contour methods (PCMs) are commonly used as they seem to fulfill most of the characteristics of an "ideal" hemodynamic monitoring system. Mostcare can continuously and real-time monitor important circulatory indicators such as cardiac output, peripheral vascular resistance index (SVRI), cardiovascular impedance (Ztot), cardiac cycle efficiency (CCE), and maximum pressure gradient (dp/dt MAX). It may help identify the causes of difficulty in weaning patients from ventilators after cardiac surgery.


Clinical Trial Description

Cardiac output (CO) monitoring is of primary importance in high-risk surgery and critically ill patients. Intermittent thermodilution (ThD) by means of a pulmonary artery catheter (PAC) has been used as the reference method and to validate alternative monitoring systems. Its invasiveness, the occurrence of complications, and inability to estimate CO on a beat-by-beat basis may explain the reduction in routine use. Echocardiography is now widely used in ICUs for the complete assessment of heart function, volume status, and CO measurement. Because it has been well accepted as a first-line diagnostic tool for circulatory failure, it has been proposed as an alternative for ThD to evaluate CO in selected patient populations . A poor acoustic window, inaccurate diameter calculations, and difficulty maintaining the angle of insonation and blood flow within the recommended values may lead to inaccuracy in CO estimation.Finally, training is of major importance. Pulse contour methods (PCMs) are commonly used in operating rooms or ICUs as they seem to fulfill most of the characteristics of an "ideal" hemodynamic monitoring system. Mostcare can continuously and real-time monitor important circulatory indicators such as cardiac output, peripheral vascular resistance index (SVRI), cardiovascular impedance (Ztot), cardiac cycle efficiency (CCE), and maximum pressure gradient (dp/dt MAX). It may help identify the causes of difficulty in weaning patients from ventilators after cardiac surgery. This is a prospective observational study. Patients admitted to the ICU after cardiac surgery and mechanically ventilated for more than 72 hours were monitored for mostcare before attempting to withdraw from the ventilator, and assessment of systemic circulation and cardiac ultrasound was completed. Patients were given an spontaneous breathing test(SBT) off the ventilator. Mostcare parameters were also recorded. If the SBT experiment was successful the endotracheal tube was removed, if it failed then mostcare monitoring and assessment of circulation and ultrasound were performed again after resumption of mechanical ventilation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06230497
Study type Observational
Source Peking Union Medical College Hospital
Contact
Status Not yet recruiting
Phase
Start date February 1, 2024
Completion date November 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT02894177 - Transcutaneous Carbon Dioxide Pressure (tcPCO2) Monitoring for the Prediction of Extubation Failure in the ICU N/A
Recruiting NCT05114551 - ICU Predictive Score of WEaning Success in Patients At Risk of Extubation Failure
Completed NCT04011852 - The Role of Chest Electrical Impedance Tomography in the Pediatric Ventilator Weaning
Recruiting NCT02921347 - Switching Between Invasive and Noninvasive Ventilation to Facilitate Weaning in Difficult-weaning Patients N/A
Recruiting NCT02921334 - Early Tracheotomy for Switching Between Invasive and Noninvasive Ventilation to Facilitate Weaning N/A
Recruiting NCT06055413 - Home-based Optimization of Mechanical Ventilation in Children N/A
Active, not recruiting NCT04023643 - Pediatric Ventilation Weaning N/A
Completed NCT05254691 - WOB and Paediatric Mechanical Ventilation N/A
Recruiting NCT05999526 - Mechanical Ventilation Reconnection for One Hour After Spontaneous Breathing Trial N/A
Active, not recruiting NCT02820090 - The Predictive Effect of the Inflammatory Response on the Evacuation of Mechanical Ventilation and the Mechanism N/A
Recruiting NCT01131377 - Acetazolamide Facilitates Ventilator Weaning N/A
Not yet recruiting NCT06321848 - Weaning Ventilator Using Heart, Lung And Diaphragm Ultrasound
Completed NCT02412202 - Echocardiographic Detection of Extravascular Lung Water Increase During Weaning From Mechanical Ventilation N/A
Completed NCT00445289 - Automatic Control of Pressure Support Ventilation in Surgical Intensive Care Units N/A
Recruiting NCT05380687 - Time Course of Neuro-ventilatory Efficiency During a Spontaneous Breathing Training N/A
Terminated NCT01535755 - A Protocol to Wean From Noninvasive Mechanical Ventilation N/A
Completed NCT04711759 - Physiologic Effects of High-flow Nasal Cannula Versus Standard Oxygen Therapy Postextubation in Critically Ill Patients N/A
Completed NCT03433105 - Oxygen Uptake in Weaning of Patients From Prolonged Mechanical Ventilation
Completed NCT00505804 - A Comparison of Dexmedetomidine and Haloperidol in Patients With Intensive Care Unit (ICU)-Associated Agitation and Delirium Phase 2
Completed NCT02946502 - Handgrip Strength Value in Predicting Mechanical Ventilation Weaning N/A