Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01464346
Other study ID # CEP247
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date November 2011
Est. completion date March 2012

Study information

Verified date May 2018
Source Medtronic Diabetes
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to demonstrate the performance of the Enlite Sensor over an entire calibration and wear period of 146 hours (6 days) when inserted in the abdomen and buttock and used with the Revel 2.0 Pumps in subjects age 18 - 75 years.


Description:

The study is a multi-center, prospective single-sample correlational design without controls. Between 4 and 10 investigational sites will be used during this study. All subjects will be assigned to treatment. Each subject will wear the following devices:

1. Enlite Sensors (2) connected to MiniLinks (2)

2. Revel 2.0 Pumps (2)

During the study each subject will be wearing 2 sensors and 2 pumps simultaneously. The pumps will be differentiated by color, and will have different calibration requirements during the in-clinic portions of the study. During the Frequent Sampling Tests:

- GREEN pump will be calibrated 3-4 times spread throughout the day

- RED pump will have the minimum calibration requirements (every 12 hours after the second calibration)

During home use (outside the clinic) BOTH pumps will be calibrated 3-4 times spread throughout the day.

Sensors will be connected to the MiniLink (integrated with the Revel 2.0 Pumps)

Subjects will wear the devices for a 3-day training period, followed by a 6-day study period. During the study period, each subject will undergo three 12-hour Frequent Sampling Tests. During the Frequent Sampling Tests, IV blood samples will be drawn every 5-15 minutes and analyzed using the YSI. The Frequent Sampling Tests will occur during the following hours of sensor wear: hours 2-14, hours 14-26, hours 50-62 hours 62-74, and hours 122-134 hours 134-146 which is representative of a complete calibration and wear period to support the proposed labeling claim of 144 hours of use.

Even though participants were randomly assigned with respect to timing of frequent sample test and sensor insertion locations, data was collected as a whole and there was no intention to analyze the two groups separately. Please note that subjects were randomly assigned to one of 3 different sensor insertion site combinations: abdomen/abdomen, buttock/buttock, and abdomen/buttock

During each Frequent Sampling Test, subjects with an established insulin sensitivity ratio and insulin carbohydrate ratio will undergo a hypoglycemic challenge (glucose lowered to a target of 50-75 mg/dL for ~2 hours, including 30 minutes between 50-60 mg/dL) and a hyperglycemic challenge (glucose raised to a target of 180-400 mg/dL for ~2 hours, including 30 minutes between 350 -400 mg/dL). Subjects will continue with their current diabetes regimen (including glucose monitoring with their own meter when desired) independent of the study devices. The Revel 2.0 Pumps will not be used to infuse insulin or manage the subject's diabetes during this study. The Enlite Glucose sensor will not be used to manage the subject's diabetes during this study. The investigational Study Meter may be used for confirmation of alarms, treatment decisions and calibration of sensor.


Recruitment information / eligibility

Status Completed
Enrollment 90
Est. completion date March 2012
Est. primary completion date March 2012
Accepts healthy volunteers No
Gender All
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria:

1. Subject is 18 - 75 years of age at time of screening

2. A clinical diagnosis of type 1 or 2 diabetes as determined by the

Investigator, for a minimum of 12 months duration:

- Criteria for type 1 diabetes:

- Required: Age of onset < 40 years of age

- Required: History of insulin use only for management of diabetes

- Required: history of normal weight or underweight at time of diagnosis.

- Not required: Initial presentation of diabetic ketoacidosis.

- Not required: History of diabetic ketoacidosis

- Not required: Low fasting C-peptide

- Criteria for type 2 diabetes:

- Required: Age of onset ~ 40 years of age

- Required: History of initial oral anti-diabetic use

- Required: History of being overweight at time of diagnosis.

- Type 2 insulin requiring is defined by type 2 diabetes subjects taking insulin with or without oral anti-diabetic agent and may also include: incretin mimetic, pramlintide or GLP agonist

- Type 2 non-insulin requiring is defined by type 2 diabetes subjects who take oral medications and may also include: incretin mimetic, pramlintide or GLP agonist

3. Adequate venous access as assessed by investigator or appropriate staff

Exclusion Criteria:

1. Subject is unable to tolerate tape adhesive in the area of sensor placement.

2. Subject has any unresolved adverse skin condition in the area of sensor or device placement (e.g., psoriasis, rash, Staphylococcus infection)

3. Subject is actively participating in an investigational study (drug or device) wherein they have received treatment from an investigational study (drug or device) in the last 2 weeks

4. Subject has a positive pregnancy screening test

5. Subject is female and plans to become pregnant during the course of the study

6. Subject has had a hypoglycemic seizure within the past 6 months

7. Subject has a history of a seizure disorder

8. Subject has central nervous system or cardiac disorder resulting in syncope

9. Subject has a history of myocardial infarction, unstable angina, coronary artery bypass surgery, coronary artery stenting, transient ischemic attack (TIA), cerebrovascular accident (CVA), angina, congestive heart failure, ventricular rhythm disturbances or thromboembolic disease

10. Subjects with hematocrit lower than 36%

11. SUbjects with a history of any cardiac arrhythmia, including atrial arrhythmias

12. Subjects with a history of adrenal insufficiency

13. Subjects with migraines

Study Design


Intervention

Device:
Enlite Sensor
This is the Enlite sensor (all subjects)

Locations

Country Name City State
United States University of Colorado Denver/Barbara Davis Center for Childhood Diabetes Aurora Colorado
United States Profil Institute for Clinical Research Chula Vista California
United States AMCR Institue Escondido California
United States University of California, San Diego La Jolla California
United States Oregon Health & Science University Portland Oregon
United States Rainier Clinical Research Center Renton Washington
United States Diablo Clinical Research Walnut Creek California

Sponsors (1)

Lead Sponsor Collaborator
Medtronic Diabetes

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Other Mean Absolute Relative Difference (MARD) Between Sensor and YSI for Abdomen Insertion Site, With 3-4 Calibrations Throughout the Day This measure is the Mean Absolute Relative Difference (MARD) between sensor glucose values and and paired YSI plasma glucose values for Abdomen insertion site, with 3-4 Calibrations, across all Abdomen insertion site participants and all days. MARD is calculated by absolute value of [(sensor glucose value - YSI glucose value) / YSI glucose value] * 100 Days 1, 3 and 6 of sensor wear
Other Mean Absolute Relative Difference (MARD) Between Sensor and YSI for Abdomen Insertion Site, With Calibration Every 12 Hours This is a measure of Mean Absolute Relative Difference (MARD) between the sensor and the paired YSI plasma glucose value for sensors inserted in the Abdomen insertion site, with Calibration every 12 hours, across all Abdomen insertion site participants and all days. MARD is calculated by absolute value of [(sensor glucose value - YSI glucose value) / YSI glucose value] * 100 Days 1, 3 and 6 of sensor wear
Other Mean Absolute Relative Difference (MARD) Between Sensor and YSI for Buttock Insertion Site, With 3-4 Calibrations Throughout the Day This measure is the Mean Absolute Relative Difference (MARD) between sensor glucose value and paired YSI plasma glucose measurement for sensors inserted in the Buttock insertion site, with 3-4 Calibrations, across all Buttock insertion site participants and all days. MARD is calculated by absolute value of [(sensor glucose value - YSI glucose value) / YSI glucose value] * 100 Days 1, 3 and 6 of sensor wear
Other Mean Absolute Relative Difference (MARD) Between Sensor and YSI for Buttock Insertion Site, With Calibration Every 12 Hours This measure is the Mean Absolute Relative Difference (MARD) between sensor glucose values and paired YSI plasma glucose values for sensors inserted in the Buttock insertion site, with Calibration every 12 hours, across all Buttock insertion site participants and all days. MARD is calculated by absolute value of [(sensor glucose value - YSI glucose value) / YSI glucose value] * 100 Days 1, 3 and 6 of sensor wear
Primary Mean Daily Agreement (Percent of Sensor Values Within 30% of Reference Value) With Minimum Calibration, Combined Abdomen and Buttock Insertion Sites Primary endpoint is mean of daily percentage of sensor values within 30% of reference value (within 22.5 mg/dL if YSI <75 mg/dL) with the minimum calibration (every 12 hour), combined abdomen and buttock insertion sites across all participants and all days. Days 1, 3 and 6 of sensor wear
Secondary Mean Daily Agreement (Percent of Sensor Values Within 30% of Reference Value) With 3-4 Calibrations Per Day, Combined Abdomen and Buttock Insertion Secondary endpoint is mean of daily percentage of sensor values within 30% of reference value (within 22.5 mg/dL if YSI <75 mg/dL) with 3-4 calibrations per day, combined abdomen and buttock insertion sites across all participants and all days. Days 1, 3 and 6 of sensor wear
See also
  Status Clinical Trial Phase
Completed NCT02771093 - An Exploratory Study of the Effects of Trelagliptin and Alogliptin on Glucose Variability in Patients With Type 2 Diabetes Mellitus Phase 4
Completed NCT02545842 - Assessment Study of Three Different Fasting Plasma Glucose Targets in Chinese Patients With Type 2 Diabetes Mellitus (BEYOND III/FPG GOAL) Phase 4
Recruiting NCT03436212 - Real-Life Home Glucose Monitoring Over 14 Days in T2D Patients With Intensified Therapy Using Insulin Pump. N/A
Completed NCT03244800 - A Study to Investigate Different Doses of 0382 in Overweight and Obese Subjects With Type 2 Diabetes Mellitus. Phase 2
Completed NCT03960424 - Diabetes Management Program for Hispanic/Latino N/A
Withdrawn NCT02769091 - A Study in Adult Patients With Nonalcoholic Steatohepatitis Who Also Have Type 2 Diabetes Phase 2
Recruiting NCT06065540 - A Research Study to See How Well CagriSema Compared to Semaglutide, Cagrilintide and Placebo Lowers Blood Sugar and Body Weight in People With Type 2 Diabetes Treated With Metformin With or Without an SGLT2 Inhibitor Phase 3
Recruiting NCT05008276 - Puberty, Diabetes, and the Kidneys, When Eustress Becomes Distress (PANTHER Study)
Completed NCT04091373 - A Study Investigating the Pharmacokinetics of a Single Dose Administration of Cotadutide Phase 1
Completed NCT03296800 - Study to Evaluate Effects of Probenecid, Rifampin and Verapamil on Bexagliflozin in Healthy Subjects Phase 1
Recruiting NCT06212778 - Relationship Between Nutritional Status, Hand Grip Strength, and Fatigue in Hospitalized Older Adults With Type 2 Diabetes Mellitus.
Completed NCT05979519 - Fresh Carts for Mom's to Improve Food Security and Glucose Management N/A
Recruiting NCT05579314 - XW014 in Healthy Subjects and Patients With Type 2 Diabetes Mellitus (T2DM) Phase 1
Completed NCT03859934 - Metabolic Effects of Melatonin Treatment Phase 1
Terminated NCT03684642 - Efficacy and Safety of Efpeglenatide Versus Dulaglutide in Patients With Type 2 Diabetes Mellitus Inadequately Controlled With Metformin Phase 3
Completed NCT03248401 - Effect of Cilostazol on Carotid Atherosclerosis Estimated by 3D Ultrasound in Patients With Type 2 Diabetes Phase 4
Completed NCT03644134 - A Personalized Intervention to Manage Physiological Stress and Improve Sleep Patterns N/A
Completed NCT05295160 - Fasting-Associated Immune-metabolic Remission of Diabetes N/A
Completed NCT02836873 - Safety and Efficacy of Bexagliflozin in Type 2 Diabetes Mellitus Patients With Moderate Renal Impairment Phase 3
Completed NCT02226003 - Efficacy and Safety of Ertugliflozin (MK-8835/PF-04971729) With Sitagliptin in the Treatment of Participants With Type 2 Diabetes Mellitus (T2DM) With Inadequate Glycemic Control on Diet and Exercise (MK-8835-017) Phase 3