Clinical Trial Summary

Newly available ceramic CAD-CAM blocs containing a screw channel for chairside-made crowns to be adhesively cemented to a TiBase abutment and screw-retained to an implant are appealing to the clinician, considering the time efficiency (one appointment) and overall lower costs as no dental laboratory is involved. The hypotheses are that the biological (BOP, PD, PCR, implant bone level) and mechanical outcomes (fracture, loss of retention, wear) are equivalent to implant screw-retained Porcelain-Fused-to-Metal (PFM) crowns over a 5 year observation time.This RCT will provide key information as to the cost/benefit, suitability and/or limitations of these chair-side hybrid-abutment crowns in the posterior region.


Description:

This RCT involves the University of Geneva Dental School and four private practices for which the Geneva Hospital Ethic Committee's approval is required. Patients in need for replacement of single unit posterior teeth will be recruited at the Dental School as well as in the 5 private practices based on specific selection criteria. Patients will be randomly assigned to a restorative group using a computer-generated random number table for allocation. The CAD-CAM blocs containing a screw channel for implant-retained chairside-made single-unit hybrid-abutment crowns are 1) Lithium-disilicate glass-ceramic (e.max CAD) (G1) and 2) feldspath-ceramic infiltrated by polymer (Enamic) (G2). The CAD-CAM crowns are adhesively cemented to titanium base abutments (Ti-base) and screw-retained to Titanium implants (Straumann Standard Plus) in the premolar (RN) and molar region (WN). Controls are screw-retained PFM crowns (G3). The number of crowns in each group is N=30 (15 molars and 15 premolars) which gives a total of 90 crowns for this study. Participants are recalled after 1 week-10 days after crown insertion (baseline, T0) and then yearly during 5 years (T1-T5). Digital X-Rays are taken at T0, T1, T3 and T5 with repositionable individual resin bite registrations.


Recruitment information / eligibility

Status Completed
Enrollment 90
Est. completion date December 8, 2023
Est. primary completion date December 8, 2023
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 25 Years to 70 Years
Eligibility Inclusion Criteria: - Absence of relevant medical condition - Need for a single crown on implant in the molar or premolar region with existing adjacent and antagonist teeth - No active periodontal or pulpal diseases - Teeth with good restorations - Straumann regular (premolar) and wide neck (molar) implants, osseo-integrated for a minimum of 2 months and facial keratinized mucosa width of at least 2 mm - Patient agrees to return for follow-up examinations during 5 years - Patient agrees to immediately inform the operator in case of problem Exclusion Criteria: - evidence of bruxism - 2 adjacent implants - implants placed of-axis

Study Design


Related Conditions & MeSH terms


Intervention

Device:
PFM Crowns on gold coping cast-on
Classic impressions are taken by the operators and sent to one and same laboratory who will deliver all the screw-retained PFM restorations. The crowns will be made using a gold coping cast-on synOcta gold abutment (Ceramicor) for wide (WN) or regular (RN) neck
hybrid abutment lithium disilicate crown
Intraoral digital impression with respective scanbodies (Sirona) for Cerec OmniCam or Cerec Bluecam over the chosen TiBase. Cerec CAD designing (operator) and CAM milling (Cerec MCXL) of single crowns with perforated blocs (e.max CAD). crystallization/ characterization/ glaze firing for the e.max CAD crown using an oven with specific firing programmes for e.max CAD. Adhesive cementation steps of the ceramic crown onto the TiBase
hybrid abutment ceramic polymer infiltrated crown
Intraoral digital impression with respective scanbodies (Sirona) for Cerec OmniCam or Cerec Bluecam over the chosen TiBase. Cerec CAD designing (operator) and CAM milling (Cerec MCXL) of single crowns with perforated blocs (Enamic). Surface polishing with rubber polishers. Adhesive cementation steps of the ceramic crown onto the TiBase

Locations

Country Name City State
Switzerland University Clinics of Dental Medicine Geneva

Sponsors (2)

Lead Sponsor Collaborator
Susanne Scherrer ITI Foundation

Country where clinical trial is conducted

Switzerland, 

Outcome

Type Measure Description Time frame Safety issue
Other Bone level Bone level changes in mm will be monitored through standardized X Rays from registration bites at various time frames (T1, T3 and T5 years) T1, T3 and T5 years
Primary survival The primary aim is to monitor and compare the survival of the two CAD-CAM hybrid abutment crown materials with that of PFM implant screw-retained crowns in the posterior region over a period of 5 years. The survival data is subdivided into "absolute failures" needing replacement of the restoration and "relative failures" which include complications that could be repaired. 5 years
Secondary Occlusal surface wear Surface wear generated at occlusal contacts from antagonist teeth will be monitored using silicone replicas of the crowns poured with epoxy resin and gold-cotaed for scanning electron microscopy. The contact wear surface will be expressed in mm^2. The average roughness in Ra values. 5 years
See also
  Status Clinical Trial Phase
Completed NCT03041597 - Dental Implant Supported Removable Dental Prostheses N/A
Enrolling by invitation NCT05589519 - Partial Implant-supported Rehabilitation Using PEEK N/A
Recruiting NCT05649085 - Evaluation of Single-unit Implant-supported Prostheses Survival Using CoCr Prosthetic Abutments: Prospective Observational Study
Active, not recruiting NCT05589493 - Hybrid PEEK-Acrylic Resin Prostheses and the All-on-4 Concept for Full-Arch Rehabilitation - Routine Group N/A
Active, not recruiting NCT04374201 - 14y Prospective Study on Posterior Zirconia-based 3-unit FDPs
Recruiting NCT04688593 - Clinical and Functional Outcome of the MobileLink Acetabular Cup System in the Short-, Mid-, and Longterm Follow-up
Completed NCT04446078 - Hybrid Polyetheretherketone (PEEK)-Acrylic Resin Prostheses and the All-on-4 Concept for Full Arch Rehabilitation N/A
Active, not recruiting NCT05261204 - Transcatheter Aortic Valve Implantation Versus Standard Surgical Aortic Valve Operation
Active, not recruiting NCT06114069 - Prosthetic Management of All on Four Versus All on Six to Rehabilitate Completely Edentulous Maxillary Ridge Opposed by Natural Teeth N/A
Recruiting NCT02409186 - A Phase III Study of Nimotuzumab Plus Concurrent Chemoradiotherapy in Loco-regional Esophageal Squamous Cell Carcinoma Phase 3
Not yet recruiting NCT06433700 - Risk of Revision Following Knee Arthroplasty in Bariatric Surgery Patients
Enrolling by invitation NCT05589545 - PEEK Prostheses in the All-on-4 Concept Using Zygomatic Implants for Full-arch Rehabilitation. N/A
Completed NCT04748458 - Long-term Outcomes of Conical Tapered Stems in Cementless Total Hip Arthroplasty Due to Congenital Hip Pathologies
Completed NCT02931903 - Lithium Disilicate Glass-ceramic Versus Hybrid Ceramic Superstructure Materials on Implant Stability N/A
Completed NCT01918124 - A Phase II Trial of Adjuvant Radiotherapy Combined With Chemotherapy for Patients With High-risk Endometrial Cancer Phase 2
Recruiting NCT06422260 - Four-unit Implant Supported Fixed Partial Dentures Fabricated From Different Materials
Recruiting NCT04960098 - Patient-reported Outcome Measures in Patient Underwent Total Hip and Knee Arthroplasty
Not yet recruiting NCT02941575 - Patient Satisfaction and Peri-Implant Tissue Success of Hybrid Ceramic Versus E-Max Superstructures N/A
Completed NCT00374946 - A Clinical Evaluation of Wear Couples in THA N/A
Completed NCT04244929 - Multicenter Perspective Study: Clinical Evaluation of the Persona MC® With Preservation or Sacrifice of the PCL N/A