NCT number NCT06141941
Other study ID # 202101006
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date June 1, 2021
Est. completion date April 2024

Study information

Verified date November 2023
Source University of Iowa
Contact Andrea Greiner, MD
Phone +1 319 356 3180
Email andrea-greiner@uiowa.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study will examine whether continuous glucose monitoring in patients hospitalized in the immediate postpartum period is more effective than traditional point of care glucose testing in identifying patients with hypoglycemia.


Description:

This is a prospective cohort study of women with type 1 and type 2 diabetes in the postpartum period. After obtaining informed consent, a CGM device (Dexcom sensor and transmitter) will be placed by research personnel upon presentation to labor or in prenatal clinic if seen within 3 days of planned induction of labor or planned cesarean section. Patient will be assisted in getting the Dexcom G6 app on their cell phone to be the receiver of glucose data. Patients who are currently using the Dexcom CGM for routine monitoring of their glucoses, will be allowed to continue using their own sensor and transmitter. Upon presentation to Labor and Delivery, patients will be assisted in activating the Share App on their cell phone. Labor and Delivery Nursing Staff will be given a Samsun phone with the Follow app in order to receive glucose data. The Samsung phone will be transferred to the Mother/Baby Unit with the patient after delivery. Glucose values from the CGM device will then be available to nursing through the Samsung phone. Nursing will be able to see current glucose data on their patient and would receive alarms to indicate hypoglycemia or impending hypoglycemia. Nursing will be provided with instructions for how to access the CGM follow app and how to appropriately respond to the alarms. Nursing will continue to perform standard of care blood glucose monitoring per routine protocol but will also obtain a finger stick to validate a blood glucose level whenever a low CGM alarm sounds. Low blood glucose values <70 mg/dl will be treated per local institutional nursing policy. Monitoring of glucose levels through the CGM device will continue throughout their postpartum hospital stay. This is typically 2 days for a vaginal delivery, 3 days for a cesarean section. Patients who do not use CGM as part of their routine care, will have their CGM sensor and transmitter removed prior to discharge from the hospital. Following discharge from the hospital, there will be no additional long term follow-up. Data we plan to collect for analysis includes: type of diabetes (DM1/DM2), point of care glucose values, number of hypoglycemic events, number of times treated for hypoglycemia.


Recruitment information / eligibility

Status Recruiting
Enrollment 40
Est. completion date April 2024
Est. primary completion date January 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Female
Age group 18 Years to 50 Years
Eligibility Inclusion: 1- Individuals in the third trimester of pregnancy admitted to the hospital with diabetes type 1 or diabetes type 2, own a smart device (which will serve as a receiver for the CGM device) Exclusion: 1. Patients less than 18 years of age 2. non-English speaking patients 3. gestational diabetes 4. extensive skin changes/diseases that inhibit wearing a sensor on normal skin, known allergy to adhesives

Study Design


Related Conditions & MeSH terms


Intervention

Device:
CGM
Continuous glucose monitoring

Locations

Country Name City State
United States University of Iowa Hospitals and Clinics Iowa City Iowa

Sponsors (1)

Lead Sponsor Collaborator
Andrea L. Greiner

Country where clinical trial is conducted

United States, 

References & Publications (3)

Feig DS, Donovan LE, Corcoy R, Murphy KE, Amiel SA, Hunt KF, Asztalos E, Barrett JFR, Sanchez JJ, de Leiva A, Hod M, Jovanovic L, Keely E, McManus R, Hutton EK, Meek CL, Stewart ZA, Wysocki T, O'Brien R, Ruedy K, Kollman C, Tomlinson G, Murphy HR; CONCEPTT Collaborative Group. Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial. Lancet. 2017 Nov 25;390(10110):2347-2359. doi: 10.1016/S0140-6736(17)32400-5. Epub 2017 Sep 15. Erratum In: Lancet. 2017 Nov 25;390(10110):2346. — View Citation

Singh LG, Satyarengga M, Marcano I, Scott WH, Pinault LF, Feng Z, Sorkin JD, Umpierrez GE, Spanakis EK. Reducing Inpatient Hypoglycemia in the General Wards Using Real-time Continuous Glucose Monitoring: The Glucose Telemetry System, a Randomized Clinical Trial. Diabetes Care. 2020 Nov;43(11):2736-2743. doi: 10.2337/dc20-0840. Epub 2020 Aug 5. — View Citation

Spanakis EK, Levitt DL, Siddiqui T, Singh LG, Pinault L, Sorkin J, Umpierrez GE, Fink JC. The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System. J Diabetes Sci Technol. 2018 Jan;12(1):20-25. doi: 10.1177/1932296817748964. Epub 2017 Dec 13. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Glucose values glucose values obtained from CGM application Postpartum admission, 2-4 days
See also
  Status Clinical Trial Phase
Completed NCT05553275 - Permissive Intrapartum Glucose Control N/A
Completed NCT03504592 - Smartphone Utilization for Glucose Monitoring and Antenatal Reporting N/A
Completed NCT02793505 - Safety of Metformin in Pregnancy N/A
Not yet recruiting NCT05152589 - Maternal Diabetes in Newborns With Hearing Loss
Not yet recruiting NCT01255384 - Possible Epigenetic Changes in Offspring of Women With Pregestational and Gestational Diabetes N/A
Not yet recruiting NCT01158040 - Intrapartum Maternal Glycemic Control Using Insulin Pump Versus Insulin Drip - Cohort Observational Trial N/A