The investigators hypothesized that PeAF-by-LAWT, a personalized protocol that uses a contact-force catheter, a multichannel radiofrequency (RF) generator, and integrated LAWT information to adapt the ablation index (AI) target to the subjacent LAWT, is safe, while showing at least the same efficacy and better efficiency than the CLOSE protocol for persistent AF ablation.


Clinical Trial Description

Pulmonary vein isolation (PVI) remains the cornerstone of all catheter-based treatment strategies in atrial fibrillation (AF). Currently, PVI is recommended (class IA indication) after one failed or intolerant class I or III antiarrhythmic drug (AAD) to improve symptoms, either in paroxysmal (PaAF) or persistent AF (PeAF). However, PVI can be also considered as first-line treatment to achieve rhythm control, particularly in cases when tachycardia-induced cardiomyopathy is suspected, a circumstance likely more related to a higher AF burden or PeAF. PVI has been proven to be effective in treating PeAF, although long-term ablation outcomes have been significantly less satisfactory than in PaAF. In a recent metaanalysis, PVI in PeAF achieved an arrhythmia-free survival at 12 months of 66.7%, with > 80% of the patients off AAD. Other ablation strategies combining PVI plus additional substrate ablation (linear ablation and/or complex fractionated atrial electrogram ablation) have been unable to demonstrate better outcomes than PVI-alone. On the other hand, recent advances both in technology and ablation protocols have resulted in greatly improved outcomes after PVI. The introduction of contact force-sensing catheters, novel estimates of lesion size [ablation index (AI) or lesion size index, and the fact of ensuring lesion contiguity (≤ 6 mm inter-lesion distance) have markedly improved arrhythmia-free survival after PVI, particularly in PaAF. The CLOSE clinical study analyzed the utility of ablation index (AI), a novel formula developed to assess real-time effect of RF delivery and improve the rates of PVI, with 91.3% of the patients free from AF/AT/atrial flutter (AFL) at 12 months follow-up. The CLOSE protocol targeted an interlesion distance (ILD) of 6 mm and AI ≥ 400 at the posterior wall and ≥550 at the anterior wall. Recently, Hussein et al. demonstrated that the use of AI-guided PVI alone performed with radiofrequency energy in a point-by-point wide area circumferential ablation (WACA) pattern according to CLOSE protocol achieves good clinical outcomes in persistent AF patients at 12 months follow-up. Finally, a more recent, personalized PVI strategy, aiming for contiguous lesions with AI titration according to the local left atrial wall thickness (LAWT) as per multidetector cardiac tomography (MDCT), has demonstrated to achieve an arrhythmia-free survival > 95% at 12 months in PaAF. Up to date, there are no randomized studies for persistent AF ablation comparing the outcomes of PVI-alone procedures performed with a personalized ablation protocol that uses the information of left atrial wall thickness (LAWT), compared with the CLOSE protocol. The investigators hypothesized that PeAF-by-LAWT, a personalized protocol that uses a contact-force catheter, a multichannel radiofrequency (RF) generator, and integrated LAWT information to adapt the ablation index (AI) target to the subjacent LAWT, is safe, while showing at least the same efficacy and better efficiency than the CLOSE protocol for persistent AF ablation. This is a two-arm, single-blind, single-center, randomized controlled trial. The study will be conducted in a tertiary hospital with an electrophysiology team of qualified investigators with proven experience in performing atrial fibrillation ablation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05396534
Study type Interventional
Source Centro Medico Teknon
Contact Antonio Berruezo, MD, PhD
Phone 669761263
Email antonio.berruezo@quironsalud.es
Status Recruiting
Phase N/A
Start date July 1, 2022
Completion date September 30, 2024

See also
  Status Clinical Trial Phase
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT03650556 - Safety and Effectiveness of TactiCath™ Contact Force, Sensor Enabled™ (TactiCath SE) Catheter for Ablation of Drug Refractory, Symptomatic, Persistent Atrial Fibrillation N/A
Recruiting NCT04085731 - Driver-guided Ablation of Persistent Atrial Fibrillatiom
Withdrawn NCT02344394 - Comparison of Hybrid Ablation and Pulmonary Vein Isolation Alone vs Hybrid Ablation With PVI Plus Catheter Ablation N/A
Completed NCT01694563 - ABLATE Post Approval Study - Synergy Ablation Lesions for Non-Paroxysmal Atrial Fibrillation N/A
Terminated NCT01683045 - Efficacy and Safety Study of the Estech COBRA® Surgical System to Treat Patients With a History of Irregular Heart Beats N/A
Active, not recruiting NCT03643224 - DiamondTemp™ System for the Treatment of Persistent Atrial Fibrillation N/A
Withdrawn NCT05093868 - Electrographic Flow Mapping Validation in Patients With Persistent Atrial Fibrillation (EVAL AF) N/A
Completed NCT05152966 - Feasibility Study of the FARAPULSE™ Cardiac Ablation System Plus in the Treatment of Persistent Atrial Fibrillation(PersAFOne II) N/A
Completed NCT05043883 - Automated Assessment of PVI Using a Novel EP Recording System N/A
Completed NCT04022954 - HD Mapping of Atrial Fibrillation in Asia Pacific
Active, not recruiting NCT06124690 - Persistent Atrial Fibrillation Without the Evidence of Low-voltage Areas N/A
Not yet recruiting NCT05454111 - CARTO-Finder Guided Ablation Versus Multiscale Entropy Guided Ablation in Persistent Atrial Fibrillation N/A
Completed NCT06260670 - FLOW EVAL-AF: FLOW Mapping Electrogram VALidation in Patients With Persistent Atrial Fibrillation N/A
Active, not recruiting NCT05077670 - Hybrid Characterization of Driver Sites During Atrial Fibrillation and Sinus Rhythm
Withdrawn NCT03835338 - WATCHMAN for Concomitant Left Atrial Appendage Electrical Isolation and Occlusion to Treat Persistent Atrial Fibrillation Rhythm N/A
Completed NCT02275104 - Multimodal Image Processing Software to Guide Cardiac Ablation Therapy N/A
Not yet recruiting NCT05565183 - Combined Study of ATrial Strain and Voltage by High Density Mapping in Young Patients With Atrial Fibrillation. N/A
Completed NCT02274857 - Randomized Evaluation of Atrial Fibrillation Treatment With Focal Impulse and Rotor Modulation Guided Procedures N/A