Thoracoabdominal Aortic Aneurysms Clinical Trial
Official title:
Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
Verified date | July 2023 |
Source | University of South Florida |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The outcomes from prior clinical evaluation of the study device, including successfully treating 99% (84/85) of the intended target vessels and 96% (27/28) limb patency observed at one year, demonstrate the potential benefits of the device. When contrasted with open repair's significant complication rates and branch fenestrated device's significant anatomic and logistic limitations, the potential risk of the proposed novel graft does not outweigh the potential benefit of widened anatomic availability and improved patency rates. Given the potential benefits, the investigators feel that it is justified to expose the target patient population to the potential risk. The non-clinical testing performed by Medtronic and the clinical results reported by Sanford Health show adequate safety of the device to support an early feasibility study. The investigators would like to perform an early feasibility study under a defined and controlled protocol to collect prospective preliminary safety and device functionality data. The investigators believe an early feasibility study is most appropriate for this novel approach. The limited sample size allows adequate patient data to be collected under a controlled protocol without exposing a large patient population to the risk associated with a novel device design.
Status | Active, not recruiting |
Enrollment | 15 |
Est. completion date | April 2024 |
Est. primary completion date | January 2024 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Primary Study Arm Inclusion Criteria: - A patient may be entered into the study if the patient has at least one of the following: - An aneurysm with a maximum diameter of > 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements - Aneurysm with a history of growth > 0.5 cm in 6 months - Saccular aneurysm deemed at significant risk for rupture - Symptomatic aneurysm greater than 4.5 cm - Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit - Proximal landing zone for the thoracic bifurcation stent graft that has: - = 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) diameter in the range of 26-42 mm - Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold - Minimum branch vessel diameter greater than 5 mm - Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm - Age: = 18 years old - Life expectancy: > 1 year Exclusion Criteria: General exclusion - Patient is a good candidate for and elects for open surgical repair - Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis - Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site - Unwilling to comply with the follow-up schedule - Inability or refusal to give informed consent - Urgent or emergent presentation - Patient is pregnant or breastfeeding - Patient has a contained rupture - Patient has a ruptured aneurysm - Patient has a dissection in the portion of the aorta intended to be treated - Obstructive stenting of any or all of the visceral vessels - Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) Medical exclusion criteria - Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel. - Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed - Uncorrectable coagulopathy - Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment - Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned < 30 days of the endovascular repair - Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina) - Systemic or local infection that may increase the risk of endovascular graft infection - Baseline creatinine greater than 2.0 mg/dL - History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome) Anatomical exclusion criteria - Thrombus or excessive calcification within the neck of the aneurysm - Anatomy that would not allow maintenance of at least one patent hypogastric artery - Anatomy that would not allow primary or assisted patency of the left subclavian artery Expanded Selection Criteria Subjects who fail to meet inclusion criteria for the primary study arm may be enrolled under an expanded selection arm if they meet the following criteria. Inclusion Criteria - Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm: - Minimum branch vessel diameter less than 5 mm - Urgent or emergent presentation - Patient has a contained rupture - Patient has a ruptured aneurysm - Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated - Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) - Baseline creatinine greater than 2.0 mg/dL - Anatomy that would not allow for maintenance of at least one hypogastric artery - Anatomy that would not allow for primary or assisted patency of the left subclavian artery Or - Patient that meets the criteria for inclusion in the primary study arm and: - Would not be eligible for the primary study arm per a documented reason other than those outlined above, and - Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition. |
Country | Name | City | State |
---|---|---|---|
United States | Tampa General Hospital/ University of South Florida | Tampa | Florida |
United States | University of South Florida - South Tampa Campus | Tampa | Florida |
Lead Sponsor | Collaborator |
---|---|
University of South Florida | Medtronic, Sanford Health |
United States,
Anderson J, Nykamp M, Danielson L, Remund T, Kelly PW. A novel endovascular debranching technique using physician-assembled endografts for repair of thoracoabdominal aneurysms. J Vasc Surg. 2014 Nov;60(5):1177-1184. doi: 10.1016/j.jvs.2014.05.090. Epub 20 — View Citation
Anderson J, Nykamp M, Remund T, Kelly P. Complete endovascular debranching of the aortic arch: A report of two cases. Vascular. 2015 Jun;23(3):310-5. doi: 10.1177/1708538114542174. Epub 2014 Jul 11. — View Citation
Danielson L, Anderson J, Nykamp M, Remund T, Kelly P. Treatment of a massive left femoral arteriovenous malformation using an innovative modular hybrid bifurcated stent graft system. Ann Vasc Surg. 2014 May;28(4):1031.e15-20. doi: 10.1016/j.avsg.2013.07.0 — View Citation
Donas KP, Lachat M, Rancic Z, Oberkofler C, Pfammatter T, Guber I, Veith FJ, Mayer D. Early and midterm outcome of a novel technique to simplify the hybrid procedures in the treatment of thoracoabdominal and pararenal aortic aneurysms. J Vasc Surg. 2009 D — View Citation
Narayanan S, Shalhoub J, Karunanithy N, Burfitt N. Primary suture-anastomosis of the Viabahn endoprosthesis to a native artery. J Vasc Surg. 2010 May;51(5):1297-9. doi: 10.1016/j.jvs.2009.12.045. Epub 2010 Mar 19. — View Citation
Oderich GS, Fatima J, Gloviczki P. Stent graft modification with mini-cuff reinforced fenestrations for urgent repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2011 Nov;54(5):1522-6. doi: 10.1016/j.jvs.2011.06.023. Epub 2011 Sep 16. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Proportion of subjects free from major adverse events | Primary safety outcome: Major adverse events include death, bowel ischemia, myocardial infarction, paraplegia, renal failure, respiratory failure, and stroke | 30 days | |
Primary | Proportion of subjects with treatment success | Primary effectiveness outcome: Treatment success is defined as a composite of technical success and freedom from the following: aneurysm enlargement, aneurysm rupture, aneurysm-related mortality, conversion to open repair, secondary intervention for migration, Type I and III endoleaks, device integrity failure, and patency-related events | at 1 year | |
Secondary | Proportion of subjects with technical success | 5 years | ||
Secondary | Proportion of subjects free from individual components of primary safety endpoint | Individual components of primary safety endpoint include: death, bowel ischemia, myocardial infarction, paraplegia, renal failure, respiratory failure, stroke | at 30 days | |
Secondary | Proportion of subjects free from paraparesis | Free from paraparesis | 30 days | |
Secondary | Proportion of subjects with treatment success | Treatment success includes freedom from: aneurysm enlargement; aneurysm-related mortality; aneurysm rupture; conversion to open repair; secondary intervention for migration, type I and III endoleaks, device integrity failure (i.e. fracture), and patency-related events (i.e. device stenosis or occlusion and embolic events); renal failure; all-cause mortality; endoleaks; device integrity failure (e.g. fracture); patency-related events (i.e. device stenosis or occlusion and embolic events); other device-related events | 5 years |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05054985 -
Safety and Efficacy of a Multi-branched Thoracoabdominal Stent Graft System for Thoracoabdominal Aortic Aneurysm.
|
N/A | |
Completed |
NCT03246126 -
Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
|
N/A | |
Recruiting |
NCT04731636 -
Guo's Visceral Arteries Reconstruction: First in Man Study
|
N/A | |
Completed |
NCT02327611 -
CUstodiol Versus RInger: whaT Is the Best Agent?
|
Phase 4 | |
Completed |
NCT05266781 -
A PROpensity Score Matching Analysis on ENDovascular vs Open Thoraco-Abdominal Aortic Aneurysm Repair (PRO-ENDO TAAA Study)
|