Clinical Trials Logo

Clinical Trial Summary

Studies have shown that taking drugs to stay out of AF has limited success. This research is designed to study heart rhythm after surgical therapy, namely by measuring if there are benefits to having surgery to treat Atrial Fibrillation (AF) with the Cardioblate CryoFlex Surgical Ablation System. The system is approved and commercially available with CE mark. The purpose of this study is to support clinical evidence that the Cardioblate System is safe and effective to treat AF.


Clinical Trial Description

Introduction: Among the cardiac arrhythmias, Atrial Fibrillation (AF) is the most common sustained cardiac arrhythmia in the general population and represents an increasing problem worldwide. Management strategies for AF include combinations of various treatments, including surgery. Cox et al. developed the surgical Maze procedure to restore sinus conduction to the AV node and to restore effective, synchronized bi-atrial contraction. In an effort to address the observed challenges and make this treatment available to more subjects, modifications of the Maze pattern and new lesion patterns have being developed and tested. Devices using new technologies, like cryothermia, were developed in an effort to reduce the time required to make the lesion pattern.The Cardioblate® CryoFlex™ Surgical Ablation System has been successfully used for the surgical ablation of cardiac arrhythmias including atrial fibrillation. The system utilizes cryothermia to create the linear lesions of the surgical Maze-III procedure.

Purpose: To provide clinical evidence showing that the Cox Cryo Maze III procedure is effective and safe in subjects with longstanding persistent AF undergoing mitral valve repair or replacement.

Study objective: The study objectives were to characterize the safety and efficacy of the Medtronic Cardioblate CryoFlex Surgical Ablation System when used to treat subjects with longstanding persistent AF requiring concomitant mitral valve repair or replacement. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01558635
Study type Interventional
Source Medtronic Cardiovascular
Contact
Status Terminated
Phase N/A
Start date November 2011
Completion date January 2016

See also
  Status Clinical Trial Phase
Completed NCT01694563 - ABLATE Post Approval Study - Synergy Ablation Lesions for Non-Paroxysmal Atrial Fibrillation N/A
Withdrawn NCT05093868 - Electrographic Flow Mapping Validation in Patients With Persistent Atrial Fibrillation (EVAL AF) N/A
Completed NCT06260670 - FLOW EVAL-AF: FLOW Mapping Electrogram VALidation in Patients With Persistent Atrial Fibrillation N/A
Recruiting NCT03546374 - Medtronic Terminate AF Study N/A
Active, not recruiting NCT03732794 - AtriCure CryoICE Lesions for Persistent and Long-standing Persistent Atrial Fibrillation Treatment N/A
Withdrawn NCT04509180 - Comparison of Treatment Outcomes Between Convergent Procedure and Catheter Ablation for Persistent and Longstanding Persistent Atrial Fibrillation N/A
Enrolling by invitation NCT06134752 - Electroporation for Treatment of Atrial Fibrillation N/A
Recruiting NCT05652517 - Univu-guided Vein of Marshall Ethanol Infusion (Marshall-Merge) N/A
Completed NCT01246466 - Dual Epicardial Endocardial Persistent Atrial Fibrillation (AF) Study N/A