Airway Complication of Anesthesia Clinical Trial
Official title:
Comparison Between a Two Person Insertion With Lateral Rotation Technique of Laryngeal Mask Airway and the Classic Technique; a Randomized Controlled Trial
The laryngeal Mask Airway was developed by Brain in 1981 and was available for clinical use in the United States by 1992 and has become very popular in routine medicine practice during 10 past years . LMA would serve as a choice to be used in the emergency situations even by the inexperienced users . Nowadays due to the increasing number of outpatient anesthesia and use of short-acting anesthetics almost without the use of any muscle relaxants requires an appropriate way for safe LMA insertion. As LMA insertion is generally performed blindly, clinicians are always in search of how to place and maintain the LMA in appropriate position.
The standard method of insertion described by Dr. Brain is relatively easy, but sometimes it is impossible to insert the LMA with the standard method. However ease and time of airway management may be of special importance in emergent situations. Since its inception the LMA has undergone various modifications in type and material, which have made other methods of insertion possible, quicker and easier than the standard method. Intraoral manipulation can put the operator at risk of finger trauma and infection. However it is not possible to avoid intraoral manipulation when the standard technique or the classic LMA is used. Therefore, many studies were seeking to find new methods to improve this technique. Hwang et al. first described The 90° rotation technique in adults that involves the following steps: the entire cuff of the LMA is inserted inside the mouth, rotated counter-clockwise through 90° and advanced until the resistance of the hypopharynx is felt . The use of this method is known to increase the success rate of insertion and decrease the incidence of blood staining of the LMA and sore throat compared to standard technique . Ghai et al. showed that rotational technique may be considered as the first technique of choice for classical laryngeal mask airway insertion in children . Lopez-Gil and colleagues reported a decrease in complications with the increase in the skill of the anaesthetist . PARVIZ et al. described a two person technique which performed by the technician who performs mouth opening and jaw thrust and the anesthesiologist who inserts the laryngeal mask. They considered it as a safe and effective method to establish a secure airway in anesthetized patients.. other studies have shown that LMA insertion with partially inflated cuff is easier than deflated cuff . Current study will combine two methods of LMA insertion including two-persons and lateral rotational techniques and compare them with the standard insertion method regarding the success rate and incidence of complications. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT04498598 -
Structural Modification In Supraglottic Airway Device
|
N/A | |
| Completed |
NCT04569539 -
The Effect of a Head Elevated Positioning Device on Position, Height and Depth of the Cricothyroid Membrane in Morbidly Obese Pregnant Women in the Third Trimester.
|
N/A | |
| Recruiting |
NCT05902013 -
Video Laryngoscopy Versus Direct Laryngoscopy for Nasotracheal Intubation
|
N/A | |
| Recruiting |
NCT05657028 -
Dexmedetomidine Versus Lidocaine in Attenuating Airway Reflexes During Recovery of Thyroidectomy Patients
|
N/A | |
| Completed |
NCT04546087 -
Impact of Labor and Delivery on Ultrasound Measured Cricothyroid Membrane Depth and Height
|
N/A | |
| Completed |
NCT03395782 -
Factors Determining Oxygen Wash in During Pre-oxygenation
|
||
| Completed |
NCT03723109 -
Airway Management During TCI vs RSI Anesthesia Induction
|
||
| Recruiting |
NCT05899868 -
Utilization of Airway Stabilizing Rod
|
N/A | |
| Completed |
NCT03613103 -
Airway Injuries After Intubation Using Videolaryngoscopy Versus Direct Laryngoscopy for Adult Patients Requiring Tracheal Intubation
|
N/A | |
| Terminated |
NCT03664700 -
Observational Study of the LMA Protector
|
||
| Completed |
NCT04138121 -
Impact of Change of Head and Neck Position on Cricothyroid Membrane Localization and Membrane Height in Parturient Patients
|
N/A | |
| Not yet recruiting |
NCT03361397 -
Effect of Nebulized Lidocaine on the Quality of Laryngeal Mask Airway Insertion
|
N/A | |
| Recruiting |
NCT03366311 -
TCHCCT-Zhong-Xing-Emergency-Department-airway
|
N/A | |
| Completed |
NCT04196582 -
LMA® Gastro Airway Versus Gastro-Laryngeal Tube in Endoscopic Retrograde Cholangiopancreatography
|
N/A | |
| Completed |
NCT05769842 -
Effects of Propofol on Respiratory Adverse Events During Extubation in Children Undergoing Tonsil Adenoidectomy
|
N/A | |
| Completed |
NCT05106478 -
AuraGain Performance in Lateral Position
|
||
| Completed |
NCT04677894 -
Comparison of Video Laryngoscopy and Direct Laryngoscopy for Nasotracheal Intubation During Pediatric Dental Surgery
|
||
| Completed |
NCT03547193 -
Two Neck Ultrasound Measurements as Predictors of Difficult Laryngoscopy
|
||
| Completed |
NCT04833166 -
Comparing Full vs. Partial Glottis View Using CMAC D-Blade Video Laryngoscope in Simulated Cervical Injury Patient
|
N/A | |
| Recruiting |
NCT05680909 -
Evaluation of SaCo Videolaryngeal Mask Airway in Morbidly Obese
|