View clinical trials related to Osteoarthritis, Knee.
Filter by:The purpose of this study is twofold: 1) to use RSA to determine the migration patterns of the PA coated Triathlon Total Knee Arthroplasty components during the first 2 years postoperatively and thus determine the proportion of cases where adequate fixation is achieved, and 2) to use DEXA scanning to document peri-prosthetic bone mineral density changes in response to the PA coated Triathlon Total Knee arthroplasty over the first two postoperative years. In addition, gait assessment and validated outcome questionnaires will be utilized to quantify changes in functional status of subjects after surgery and migration patterns will be compared to results obtained from previous studies of uncemented total knee arthroplasty components conducted at this centre. Questions to be asked are: 1. Do the components achieve adequate fixation to the underlying bone? 2. What are the migration patterns (translations and rotations) of the PA coated arthroplasty components during the first two years postoperatively and are they different from that seen for other implants that have been studied with RSA at this institution? 3. For what proportion of implants does migration continue to increase during the two year follow-up? 4. Are inducible displacements, measured at weight-bearing follow-ups, consistent over time and do they indicate that adequate fixation has been achieved? 5. Are there changes over time in bone mineral density of peri-prosthetic bone in the PA coated Triathlon total knee arthroplasty? 6: Where do changes in bone mineral density occur? 7: Is there a significant difference in health status and functional outcome before and after total knee arthroplasty using PA coated Triathlon total knee arthroplasty components? 8: Are there changes in gait symmetry and centre of mass (COM) displacements as assessed with the Walkabout Portable Gait Monitor pre- and post-operatively and how does study gait data compare to asymptomatic gait? and finally, Question 9: Are there differences in the micromotion patterns between the when compared to other samples of knee implants in our RSA database?
Observational evidence suggests that vitamin D deficiency may have a role in the causes of osteoarthritis (OA) and there are biologically plausible mechanisms to explain this. There is, however, no evidence which shows that intervening with vitamin D supplementation can slow the progression of OA. This study is to determine if vitamin D supplementation can reduce knee pain and slow knee cartilage loss in OA patients comparing with a placebo. Use of MRI will provide sensitive measures of knee OA changes.
The goal of this study is to determine if the rotating platform high flex design provides improved flexion compared to the standard rotating platform TKA.
This is an open, prospective, randomized, controlled, parallel, multicenter, non-inferiority study in 250 individuals (125 individuals per group), with 204 evaluable patients with clinical and radiological diagnosis of osteoarthritis of the knee. Individuals will be randomized to receive during 180 days the test drug(glucosamine sulfate 500 mg + sodium chondroitin sulfate 400 mg - Mantecorp) or the reference medication (glucosamine sulfate 500 mg + sodium chondroitin sulfate 400 mg - Condroflex®). Efficacy will be evaluated through the clinical picture, pain visual analog scale, swelling, stiffness in the joint, consumption of paracetamol and quality of life. The safety assessment will be done by monitoring the incidence of adverse events and their relation to the treatment.
This project aims to assess two different techniques used to position the knee replacement implant during surgery. The patients will be randomised to receive either the following: 1. The established Navigation System (gold standard) 2. The new Prophecy Technique (validated by the Navigation System) The study hypothesis is there will be no difference between the gold standard Navigation system and the Prophecy technique in relation to the placement of the knee implant.
The purpose of this pilot study is to investigate the efficacy and safety of autologous transplantation, under arthroscopy, of Bone Marrow Mesenchymal stem cells, using, with a cell separator, a fresh non-culture expanded Autologous Bone Marrow derived Mesenchymal Stem, mixed and activated with proteins scaffold in patient with Knee cartilage defects and osteoarthritis. Based on extensive preclinical investigations, the technology of using freshly isolated bone marrow mononuclear cells mixed with proteins seems safe and most effective for a one-step correction of cartilage defect and restoration of the osteochondral complex, because the same mixture can generate cartilage in the vasculature-free knee joint, and bone in the environment of bone defects.
PF-04191834 works in animal models by inhibiting one of the enzymes, 5-lipoxygenasein which is involved in the pathway that causes inflammation and pain. The purpose of this study is to test how effective, safe and tolerated PF-04191834 is in patients with osteoarthritis of the knee by itself or with naproxen, particularly to test if patients have less pain.
The purpose of this study is to determine if an anti-inflammatory drug, called infliximab, will reduce inflammation in the synovial lining in patients with an early stage of osteoarthritis of the knee. It will also help determine if the study medication decreases the accumulation of synovial fluid and prevents cartilage breakdown.
The purpose of this study is to evaluate the safety and performance of Hydros Joint Therapy (Hydros) and Hydros-TA Joint Therapy (Hydros-TA) for treatment of pain from osteoarthritis of the knee, in patients who have failed to respond adequately to conservative non-pharmacologic therapy and simple analgesics.
The objective of the study is to determine the safety and tolerability of two different formulations of BMP-7 for the treatment of osteoarthritis of the knee.