View clinical trials related to Musculoskeletal Diseases.
Filter by:The main objective of the investigators is to improve the quality of care in patients with orthopedic disorders followed in St Luc hospital (Brussels Belgium). To do this, the investigators want to assess the impact of Orthopedic treatments at the structural level (bone structure, muscle, etc.), at the functional level (mobility, strength, stiffness...), on the restriction of activities of patients (walking, make its care daily..) and on the limitation of participation in the life of every day (sport, work, social life, cultural...). This functional evaluation of patients with orthopedic disorders by the ICF model is an original approach rarely used in muscular-skeletal impairments that can very improve the management of these patients and their quality of life. In addition, the investigators associate the harvesting of all medical and computer data collected by high-precision tools in the surgical treatments, to better define the surgical precision and improve the quality of surgical care.
Evaluate the benefit of an intervention by a computer program comprising active breaks, in the form of a personalized self-program on functional impairment and / or pain, among employees with latent or symptomatic upper extremity MSDs and spine (+/- eyestrain) in connection with the computer work environment.
Herb-induced liver injury is an important issue in musculoskeletal diseases where herbal medicine is most frequently used. The low prevalence of drug-induced liver injury (DILI) gives rise to the need for large-scale patient studies. We assessed the prevalence of liver injury of 6,894 musculoskeletal disease inpatients taking herbal medicine.
The purpose of this study is to determine whether seeing a physical therapist first compared with seeing a physician first is more clinically and cost effective in an occupational setting for acute musculoskeletal conditions.
The NexGen TKR (Zimmer, Warsaw, Indiana, USA) is a proven TKR design that has reported excellent medium and long-term results in clinical studies and in implant registries all around the world. As a follow-up of the NexGen TKR, an improved design has recently been introduced by Zimmer: The Persona TKR (Zimmer, Warsaw, Indiana, USA) has been used successfully in about 20.000 patients, but results from independent clinical studies have not been reported yet. The objective of this study is to accurately assess and compare migration, kinematics, prosthesis placement and patient reported outcomes of two TKR prostheses: the fixed bearing, cemented NexGen LPS, a proven design with an excellent clinical track record, and the fixed bearing, cemented Persona PS, a new design without clinical data (both designs by Zimmer, Warsaw, Indiana, USA). The primary objective is to assess and compare migration of the two TKR prostheses (Femoral and Tibial component). The secondary objective is to assess and compare clinical data, kinematics, prosthesis placement and patient reported outcome measures. This study is designed as a single-blind randomized trial between the Persona PS total knee prosthesis and the well-established NexGen total knee prosthesis. Different sample sizes are used for the different parts of this study: - 30 Patients with NexGen LPS prosthesis and 30 patients with Persona PS prosthesis for RSA - 15 Patients with NexGen LPS prosthesis and 15 patients with Persona PS prosthesis for Fluo The study population will consist of patients with symptomatic osteoarthritis of the knee scheduled for TKR surgery at the Department of Orthopaedics, Leiden University Medical Center. Annually 40 TKA procedures are performed in our department, of which about 70% is Osteo Arthritis (OA) and 30% Reumatoid Arthritis (RA). We anticipate that inclusion can be accomplished within a 2 year period. Main study parameters/endpoints are: - Migration, measured by means of RSA. - Prosthesis placement and bone resection measured by means of CT and caliper measurements of the resected bone parts. - In vivo kinematics by means of fluoroscopy. - Patient Reported Outcome Measures by means of questionaires.
The study will investigate if there are differences in the presence of: (1) prior injury, playing patterns, and physical fitness habits; (2) scapular control; and (3) cervical neuromuscular control and endurance deficits between musicians with and without current playing related musculoskeletal injuries.
This study will evaluate the safety and tolerability of single and multiple doses of ACE-083 as a local injection into selected skeletal muscles of healthy subjects. The study will also determine the amount of ACE-083 that reaches the systemic circulation following local administration. Additionally, the study will assess whether local administration into skeletal muscle results in an increase in the size and/or strength of the injected muscle.
The PFC Sigma Knee by DePuy Synthes is an excellent knee replacement with an excellent clinical track record, good survival rates (98% 10 years survival in patients aged < 55 years)(Keenan et al., 2012) and minimal early migration as measured with RSA (0.5mm MTPM at two years follow-up)(von et al., 2009). The ATTUNE™ Knee by DePuy Synthes is an advancement in knee replacement options. It is designed to provide better range of motion and address the unstable feeling some patients experience during everyday activities, such as stair descent and bending. To date (March 2013), more than 3,500 patients have received an ATTUNE Knee as part of a limited launch and positive feedback was received regarding patient recovery, stability and motion. The objective of this study is to accurately assess and compare migration, clinical and radiological outcome and patient reported outcomes of two TKR prostheses: the Cemented ATTUNE™ Fixed Bearing Cruciate Retaining Knee System and the Cemented PFC Sigma Fixed Bearing Cruciate Retaining Knee System, both by DePuy Synthes, Warsaw, Indiana, USA. The primary objective of this study is to compare the magnitude and pattern of migration of the prostheses (Femoral and Tibial component). The secondary objective of this study is to compare clinical and radiological outcome of the prostheses and PROMS. The tertiary objective of this study is to compare clinical and radiological outcome and PROMS of the prostheses with migration data. This study is designed as a single-blind, randomized trial between the ATTUNE™ Knee System and PFC Sigma Knee System. 32 patients with the ATTUNE™ Knee System and 32 patients with PFC Sigma Knee System will be included in this study. The study population will consist of patients with symptomatic osteoarthritis of the knee scheduled for TKR surgery at the Department of Orthopaedics, Medisch Centrum Haaglanden, The Hague, The Netherlands. Annually 300 TKA procedures are performed in this department, of which about 90% is Osteo Arthritis (OA) and 10% Rheumatoid Arthritis (RA) and other indications. We anticipate that inclusion can be accomplished within a 1 year period and that the total study duration is 3 years. Main study parameters/endpoints are: - Migration of the prosthesis with respect to the host bone measured by means of roentgen stereophotogrammetric analysis (RSA). - Patient Reported Outcome Measures by means of questionnaires.
The purpose of this study is to determine whether a specifically tailored value-based cognitive behavioural therapy program (V-CBT) is able to prevent the development of persistent disability, pain, and psychological distress if delivered within the first three months after a whiplash injury.
Patients seen in the Orthopaedic Trauma clinic will be asked to consent for potential video/picture recording using the Google Glass device during their visit with the orthopaedic surgeon or resident. The investigators want to record the patient's level of acceptance and response to this new technology. There are two arms: Patients seen by a doctor wearing the Google Glass device and those that will not be exposed. Both groups will be asked to complete a survey after their clinic visit. The device users (doctor) will complete a survey which will evaluate how effective this new tool is in the Orthopaedic clinical setting.