SaCo videolaryngeal mask airway is a novel third generation supraglottic device allowing for continuous observation of entrance to larynx via inserted in special channel videoscope connected with cable with external monitor. In obese patients airway management can be difficult so use of new devices that improve safety and potentially efficacy of airway management is indicated. In prospective observational study the SaCo VLM will be evaluated in terms of maintaining airway patency and effectiveness of intubation through it's lumen in morbidly obese scheduled for elective general surgery under general anesthesia.


Clinical Trial Description

Morbidly obese patients pose challenge to operator when airway management is needed. Additionally they are at increased risk of complications related to failed airway management, hypoxia and following brain injury. SaCo videolaryngeal mask airway is a nowvel third generation supraglottic device allowing for continuous observation of entrance to larynx via inserted in special channel videoscope connected with cable with external monitor. In obese patients airway management can be difficult so use of new devices that improve safety and potentially efficacy of airway management is indicated. In prospective observational study the SaCo VLM will be evaluated in terms of maintaining airway patency and effectiveness of intubation through it's lumen in morbidly obese scheduled for elective general surgery under general anesthesia. After induction to general anesthesia SaCo VLM will be inserted with continuous visualisation through camera channel and inserted videoscope and mechanical ventilation will be commenced. Ease of SaCo VLM insertion will be recorded in 5 grade scale: 1- very easy, 2- easy, 3- neutral, 4 - difficult, 5 - very difficult. Time of insertion will be recorded as time from grabbing device and opening of patient's mouth to connecting SaCo VLM to ventilator and confirming of patient's ventilation. Parameters of mechanical ventilation will be recorded: Peak pressure, Lung Compliance - from respirator monitoring system and Seal pressure (measured with following method: fresh gas flow 5 l/min, valve set at 40cmH2O, manual/spontaneuous ventilation mode - with increasing airway pressure when the leak will be recognized achieved maximum pressure will be recorded). The visualisation of entrance to larynx will be assessed on device's monitor in 4-grade scale: 1- best view - all structures of vocal cords visible, 2 - vocal cords partialy visible, 3 - only lower part of entrance to larynx visible, 4 - no visualisation of entrance to larynx). Necessary adjustements will be reorded like external pressure on thyroid cartilage, changing of SaCo VLM mask position. In case of not adequate ventilation following steps will be taken: reposition of SaCo VLM, changing of size of SaCo VLM, endotracheal intubation using videolaryngoscope. After measurements the endotracheal intubation efforts will be commensed under continuous visualisation of entrance to larynx with SaCo VLM videoscope system. Time of intubation will be recorded. Ease of intubation will be recorded in 5 grade scale: 1- very easy, 2- easy, 3- neutral, 4 - difficult, 5 - very difficult. After successful endotracheal intubation confirmed with EtCO2 the standard general anesthesia will continue. After surgery and anesthesia the possible complications will be evaluated: track of blood on device, laryngospasm, sore throat. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05680909
Study type Observational
Source Medical University of Lodz
Contact Tomasz Gaszynski, Prof
Phone +48 42 6783748
Email tomasz.gaszynski@umed.lodz.pl
Status Recruiting
Phase
Start date May 20, 2022
Completion date August 1, 2023

See also
  Status Clinical Trial Phase
Completed NCT03657927 - A Comparison of McGrath MAC Versus C-MAC Videolaryngoscopes in Morbidly Obese Patients N/A
Recruiting NCT04934826 - Comparison of the Absorption of Hydrolyzed or Intact Proteins in Morbid Obese Patients After the Roux Y Gastric Bypass N/A
Completed NCT03181347 - The Microbiology of Bariatric Surgery N/A
Completed NCT03886870 - Obesity, Lifestyle and Work Intervention N/A
Active, not recruiting NCT04433338 - The PREBA Study: Effect of Preoperative Weight Loss With a 14-day Low-calorie Diet on Surgical Procedure and Outcomes in Patients Undergoing RYGB Surgery N/A
Completed NCT03553849 - Utilization of Very Low Calorie Diet in Obese General Surgery Patients N/A
Completed NCT05854875 - Diabetes Remission After RYGBP and RYGBP With Fundus Resection N/A
Not yet recruiting NCT03203161 - Registry on Obesity Surgery in Adolescents
Not yet recruiting NCT03601273 - Bariatric Embolization Trial for the Obese Nonsurgical Phase 1
Recruiting NCT02129296 - Intragastric Balloon, Air Versus Fluid Filled: Randomized Prospective Study Phase 1/Phase 2
Active, not recruiting NCT01564732 - Multicenter Prospective Randomized Controlled Trial of Plicated Laparoscopic Adjustable Gastric Banding N/A
Completed NCT02033265 - Ultrasound-Guided Axillary Brachial Plexus Block: Influence of Obesity
Not yet recruiting NCT01652105 - Randomized Trial of Preoperative Diets Before Bariatric Surgery N/A
Completed NCT01963637 - Gastric Volumetry by Gastric Tomodensitometry With Gas N/A
Completed NCT01149512 - Outcomes of the Adjustable Gastric Band in a Publicly Funded Obesity Program N/A
Terminated NCT01759550 - Prospective Case-Series of Ligasure Advance Pistol Grip and LigaSure Blunt Tip
Completed NCT01955993 - Fentanyl Metabolism in Obese Adolescents N/A
Recruiting NCT01685177 - Single Anastomosis Duodeno-Ileal Bypass vs Standard Duodenal Switch as a Second Step After Sleeve Gastrectomy in the Super-Morbid Obese Patient N/A
Completed NCT02929212 - Effect of Number of Meals on Metabolism After Weight Loss Surgery N/A
Completed NCT00624624 - Follow-up of Serum Androgen Profile After Bariatric Surgery in Men With Obesity Related Hypogonadotropic Hypogonadism N/A