Clinical Trials Logo

Clinical Trial Summary

The investigator hypothesizes that a benign directed ultrasound, when performed after a normal digital mammogram, will provide women with focal breast pain additional reassurance that the etiology of their symptom is benign. 160 women over the age of thirty with focal breast pain who present to the Breast Imaging Clinic for evaluation between 3/1/2016 - 7/1/2018 will be selected and randomized to three groups using a block randomization technique. All study participants will complete a survey assessing psychosocial factors, then receive a digital mammogram. Patients with a negative mammogram will continue on with the study and will either have a conversation about their negative mammogram with a radiologist or receive a directed ultrasound. A second survey will be conducted assessing psychosocial factors. All study participants who did not receive an ultrasound will receive an ultrasound so that all study participants are provided with the standard of care for focal breast pain. The results of the survey will be compared and appropriate statistical analyses such as an Analysis of Variance (ANOVA) test will be conducted to determine any statistically significant differences between the three randomized groups. The risks/safety issues of this study are believed to be minimal.


Clinical Trial Description

Protocol Title: Focal Breast Pain: Does a normal ultrasound provide reassurance? Purpose of the Study: The investigator hypothesizes that a benign directed ultrasound, when performed after a normal digital mammogram, will provide women with focal breast pain additional reassurance that the etiology of their symptom is benign. Background & Significance: Breast pain is one of the most common symptoms for which women seek medical care. While up to 80% of women experience breast pain at some point in their lives, most commonly breast pain results from a benign etiology such as trauma, infection, pregnancy, lactation, or simple cysts. In contrast, breast cancer is only reported in up to 7% of women presenting with focal breast pain. Despite the uncommon association between breast cancer and focal breast pain, a diagnostic imaging workup is often requested. Current American College of Radiology (ACR) Appropriateness Criteria guidelines rate the use of mammography and ultrasound for the evaluation of non-cyclical, focal, unilateral or bilateral breast pain in patients 30 years and older as "may be appropriate." Traditionally both mammography and ultrasound are performed in women over the age of 30, who present with noncyclical, focal breast pain as imaging can often exclude a treatable benign cause of pain and/or provide reassurance. The investigator recently completed a retrospective study evaluating the utility of digital mammography and directed ultrasound in women with focal breast pain. It was observed that performing directed ultrasound following digital mammography was potentially beneficial in women with mammographically dense breast tissue. In contrast, the investigator demonstrated that directed ultrasound in conjunction with digital mammography was of low utility in women with non-dense breast tissue. These findings suggest that directed ultrasound might be unnecessary in the work up of focal breast pain for women with non-dense breast tissue. However, there is anecdotal evidence that a directed ultrasound yielding benign findings following a normal digital mammogram might further reassure women that the cause of focal breast pain is benign. These potential psychological benefits may drive the continued use of ultrasound in the work up of focal breast pain, even though their diagnostic utility is low. Design and Procedures: Subject Selection, Recruitment, and Compensation The study team (Principal investigator (PI), Co-PI, and Study coordinator) will select up to 160 women, who present to the Breast Imaging Clinic for evaluation of focal breast pain between 3/1/2016 - 7/1/2018. Inclusion criteria include women over the age of 30 with primary focal breast pain, i.e. pain localizable by the patient to within one breast quadrant without other associated symptoms. Women with diffuse, radiating, or axillary pain, associated palpable findings at the site of pain, skin changes (erythema, thickening) or nipple changes (discharge, retraction), currently pregnant or breast-feeding, history of recent trauma or infection of the affected breast, and history of ipsilateral breast cancer will be excluded. Based on the investigator's clinical judgement, the investigator anticipates a minimum effect size of d=.4 for anxiety. A sample size of n =80 per group (total n = 160) has power of 0.8 to detect differences with an effect size of d=.4 using a one-tailed alpha = .05. Study participants will include women referred for imaging because of focal breast pain and women who report focal breast pain to the technologist or radiologist prior to imaging. Once a patient is identified as a possible candidate, the PI, Co-PI, or study coordinator will look at electronic medical record, Epic. to see if they meet inclusion criteria and do not have any exclusion criteria. If there are none, the patient will be approached to see if they are willing to participate in the study. While the number of patients who present in a typical week to Duke with focal breast pain has not been studied, anecdotally, approximately 1-2 patients per day have been evaluated for focal breast pain. Study participants will not be compensated. Consent Process Study participants will include women referred for imaging because of focal breast pain and women who report focal breast pain to the technologist or radiologist prior to imaging. Once a patient is identified as a possible candidate, the PI, Co-PI, or study coordinator will look at Epic to see if they meet inclusion criteria and do not have any exclusion criteria. If there are none, the patient will be approached to see if they are willing to participate in the study. Only a member of the study team (Karen Johnson, MD, Lars Grimm, MD, and Michael Cho, MD) will approach a potential participant for the consent process. If a member of the study team is not available, the potential subject will not be recruited. Subjects who are able to provide legally effective consent will be recruited. While the number of patients who present in a typical week to Duke with focal breast pain has not been studied, anecdotally, approximately 1-2 patients per day have been evaluated for focal breast pain. This study will serve as the 3/2 research project for Michael Cho, MD. Dr. Cho has requested 37 weeks of dedicated research time during his 4th year to recruit patients. Dr. Cho will continue to recruit patients during his Breast imaging fellowship if needed. As such, Dr. Cho will be primarily responsible for the consent process. Dr. Cho will work with Steve Shipes to learn about the consent process and Maestro data entry. Study Design Once a patient volunteers to participate, the investigator will utilize a block randomization technique to randomize the study participants into two groups (Group A and B), ensuring comparable numbers across the study groups. The patient will then be consented. Pertinent demographic and medical data will also be collected. All included study participants will be asked to complete a short survey, based on the State Anxiety scale of the State-Trait Anxiety Inventory (STAI) (18). This survey will primarily assess psychosocial metrics, including, but not limited to anxiety, comfort, and level of concern for malignancy. All study participants will receive a digital mammogram, which is the standard of care for patients presenting with focal breast pain. Patients with no imaging correlate to the focal breast pain (Breast imaging-reporting and data system (BI-RADS) 1 and 2) will continue on with the study. Patients with an imaging finding at the site of focal pain (BI-RADS 0, 4, or 5) will be excluded from the study and receive the standard care that is appropriate for the imaging finding. Women with BI-RADS 1 and 2 digital mammograms will proceed with the study and be informed of their imaging findings. Study participants randomized to Group A will receive their mammogram results from a Breast imaging fellow or fellowship trained Breast imaging radiologist. Participants in Group B will receive their mammogram results from a Breast imaging fellow or fellowship trained Breast imaging radiologist and additionally receive a directed ultrasound in the area of focal pain, which is the standard of care for focal breast pain. All study participants will be asked to complete a second survey, based on the State Anxiety scale of the State-Trait Anxiety Inventory. Participants in Groups A will receive a directed ultrasound of their breast at the end of the visit ensuring that all women receive the standard of care. One of the research collaborators will approach subjects in groups A following the 2nd survey to disclose the minor deception and explain to the subjects the necessity of the deception for the purposes of the study. The collaborator will also explain that the current standard of care for patients with focal breast pain is a targeted ultrasound. The standard of care ultrasound will then be performed by a Breast imaging fellow or fellowship trained breast radiologist. Risk/Benefit Assessment The risks of this study are believed to be minimal, including the potential loss of confidentiality. The digital mammogram and directed ultrasound patients will receive are the standard of practice for women with focal breast pain. Women in this study would have received these imaging tests regardless of their participation in the study and therefore the potential risks of imaging are not considered additional risks of this study. Costs to the Subject: There are no projected direct financial costs to the subjects involved in this study. Data Analysis & Statistical Considerations: The results of the survey will be compared and appropriate statistical analyses including but not limited to analysis of variance and multiple two sample t-tests conducted to determine any statistically significant differences between the three randomized groups. Data & Safety Monitoring: There are no anticipated safety concerns. The study coordinator (MC) will be responsible for the data collection and storage. Paper surveys will be stored in a locked cabinet in the Breast imaging reading room (Cancer Center Room 2S33) in the Cancer Center Breast Imaging Department (Clinic 2-1) which is accessible by badge only. Any digital data will be stored on an encrypted external hard drive (Western Digital) with a backup on Duke approved cloud storage (Box) and DTHS managed shared drive. Privacy, Data Storage & Confidentiality: A de-identification code will be assigned to the patients to be used as their identifier. The linking code identifying the subject will be kept for the duration of the study and will be securely stored on an encrypted external hard drive (Western Digital) with a backup on Duke approved cloud storage (Box) and DTHS managed shared drive. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02810236
Study type Interventional
Source Duke University
Contact
Status Completed
Phase N/A
Start date February 1, 2018
Completion date November 30, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT05246202 - Personalized Feedback Intervention for Latinx Drinkers With Anxiety N/A
Active, not recruiting NCT05777044 - The Effect of Hatha Yoga on Mental Health N/A
Recruiting NCT04680611 - Severe Asthma, MepolizumaB and Affect: SAMBA Study
Completed NCT04512768 - Treating Comorbid Insomnia in Transdiagnostic Internet-Delivered Cognitive Behaviour Therapy N/A
Completed NCT04748367 - Leveraging on Immersive Virtual Reality to Reduce Pain and Anxiety in Children During Immunization in Primary Care N/A
Recruiting NCT05563805 - Exploring Virtual Reality Adventure Training Exergaming N/A
Completed NCT04579354 - Virtual Reality (VR) Tour to Reduce Preoperative Anxiety Before Anaesthesia N/A
Completed NCT03535805 - Transdiagnostic, Cognitive and Behavioral Intervention for in School-aged Children With Emotional and Behavioral Disturbances N/A
Completed NCT03457714 - Guided Internet Delivered Cognitive-Behaviour Therapy for Persons With Spinal Cord Injury: A Feasibility Trial
Recruiting NCT05956912 - Implementing Group Metacognitive Therapy in Cardiac Rehabilitation Services (PATHWAY-Beacons)
Active, not recruiting NCT05302167 - Molehill Mountain Feasibility Study. N/A
Completed NCT05881681 - A Mindfulness Approach to UA for Afro-descendants N/A
Completed NCT05588622 - Meru Health Program for Cancer Patients With Depression and Anxiety N/A
Active, not recruiting NCT04961112 - Evaluating the Efficacy of Cranial Electrotherapy Stimulation in Mitigating Anxiety-induced Cognitive Deficits N/A
Recruiting NCT04612491 - Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
Completed NCT05980845 - The Effect Nature Sounds and Music on Hemodialysis Patients N/A
Recruiting NCT05449002 - Digital Single Session Intervention for Youth Mental Health N/A
Completed NCT05585749 - Virtual Reality Application on Pain Intensity and Anxiety Level in Endoscopy Patients N/A
Terminated NCT03272555 - WILD 5 Wellness: A 30-Day Intervention N/A
Recruiting NCT05997849 - Development of a Multiplatform Mental Health Mobile Tool N/A