Administrative data

NCT number NCT05491655
Other study ID # MGH_003
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date March 29, 2023
Est. completion date February 2025

Study information

Verified date November 2023
Source Miulli General Hospital
Contact Grigorios Katsouras, MD, MSc
Phone 0803054219
Email g.katsouras@miulli.it
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or RBBB through AV delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening. This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD.


Description:

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or Right Bundle Branch Block (RBBB) through atrioventricular (AV) delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening. This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD. All patients will be implanted with a CRT (Cardiac Resynchronization Therapy) defibrillator with one of the leads positioned on the His bundle to obtain direct His-bundle capture. (There will be a 1-month run-in period where the output voltage will be 3.5 Volts/1 or 2V/1msec according to the group so as to obtain stable threshold). A single-blinded design will then be employed to investigate the effect of His bundle pacing. Patients will be allocated in random order to six-month treatment periods in each of the following two states (1) 3.5 Volts/1 msec pacing output direct His-bundle pacing, AV delay will be programmed in order to obtain a PR interval of 120-140msec; (2)back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R-DDD(R) 60bpm). Endpoint measurements will be taken at baseline, 1 month run-in period of 3.5 Volts/1 msec or 2V/1msec pacing output and 6 months post randomization. Treating Physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will be performed in a blinded manner. Treatment allocation will be blinded to the endpoint assessor and the patient. Patients entering the study will attend for implantation of a CRT pacemaker device with one lead positioned on the His bundle. This will be performed in Miulli General Hospital (and other participating centres) no later than 2 months after the patient's screening visit. Before the intervention patients will be randomized to either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60) for 6 months. All patients will be implanted with an Implantable cardioverter defibrillator (ICD) and an ICD lead in the right ventricle (RV) (either RV apex or RV septum). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle to obtain direct His-bundle capture. After implantation of the device there will be a 1-month run-in period that the device will be programmed to deliver His bundle pacing therapy during this period at 3.5 Volts/1msec or 2V/1msec according to the assignment group. One month after patients are implanted with their device, patients will either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60bpm) for 6 months. Treatment allocation will be obtained using an Interactive Web Response System (IWRS) programmed with a randomization schedule provided by the trial statistician. Appropriate blocking will be used.


Recruitment information / eligibility

Status Recruiting
Enrollment 34
Est. completion date February 2025
Est. primary completion date February 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years to 90 Years
Eligibility Inclusion Criteria: - Aged 18 or above - Ventricular Ejection Fraction (EF) < 50%; BNP needs to be =250ng/L or N Terminal-pro BNP=600ng/L for patients with EF 36-50% and they should have an ICD indication - New York Heart Association (NYHA) class I-IV - Narrow QRS duration (=110ms) on 12 lead ECG Exclusion Criteria: - Other serious medical condition with life expectancy of less than 1 year - Lack of capacity to consent - Pregnancy - Previous aortic valve surgery

Study Design


Related Conditions & MeSH terms


Intervention

Device:
High Intensity His Bundle pacing
All patients will be implanted with an Implantable cardioverter defibrillator (ICD) and an ICD lead in the right ventricle (either RV apex or RV septum). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle to obtain direct His-bundle capture.

Locations

Country Name City State
Italy Miulli General Hospital Acquaviva Delle Fonti Bari

Sponsors (1)

Lead Sponsor Collaborator
Miulli General Hospital

Country where clinical trial is conducted

Italy, 

References & Publications (4)

Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM; Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004 May 20;350(21):2140-50. doi: 10.1056/NEJMoa032423. — View Citation

Cleland JG, Abraham WT, Linde C, Gold MR, Young JB, Claude Daubert J, Sherfesee L, Wells GA, Tang AS. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure. Eur Heart J. 2013 Dec;34(46):3547-56. doi: 10.1093/eurheartj/eht290. Epub 2013 Jul 29. — View Citation

Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, Saleem M, Mandrola J, Genovese D, Tung R; His-SYNC Investigators. His Corrective Pacing or Biventricular Pacing for Cardiac Resynchronization in Heart Failure. J Am Coll Cardiol. 2019 Jul 9;74(1):157-159. doi: 10.1016/j.jacc.2019.04.026. Epub 2019 May 9. No abstract available. — View Citation

Whinnett ZI, Shun-Shin MJ, Tanner M, Foley P, Chandrasekaran B, Moore P, Adhya S, Qureshi N, Muthumala A, Lane R, Rinaldi A, Agarwal S, Leyva F, Behar J, Bassi S, Ng A, Scott P, Prasad R, Swinburn J, Tomson J, Sethi A, Shah J, Lim PB, Kyriacou A, Thomas D, Chuen J, Kamdar R, Kanagaratnam P, Mariveles M, Burden L, March K, Howard JP, Arnold A, Vijayaraman P, Stegemann B, Johnson N, Falaschetti E, Francis DP, Cleland JGF, Keene D. Effects of haemodynamically atrio-ventricular optimized His bundle pacing on heart failure symptoms and exercise capacity: the His Optimized Pacing Evaluated for Heart Failure (HOPE-HF) randomized, double-blind, cross-over trial. Eur J Heart Fail. 2023 Feb;25(2):274-283. doi: 10.1002/ejhf.2736. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Change in left ventricular ejection fraction change in left ventricular ejection fraction measured by 2D echo at 6 months compared to baseline Baseline pre-intervention, randomisation and 6 months post randomisation
Secondary Changes in B-type Natriuretic Peptide (BNP) Measured from blood samples Baseline pre-intervention, randomisation and 6 months post randomisation
Secondary Changes in Quality of Life (QOL) Scores Change in QOL measured by the Kansas City Cardiomyopathy Questionnaire at 1 and 6 months compared to baseline. Scores are scaled 0-100, where 0 denotes the lowest reportable health status and 100 the highest Baseline pre-intervention,1 and 6 months post randomisation
Secondary Changes in arrhythmia burden Measured during Pacemaker control 1 month and 6 months post randomization.
See also
  Status Clinical Trial Phase
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05654272 - Development of CIRC Technologies
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy