Clinical Trial Summary

Approximately one third of patients treated with cardiac resynchronization therapy (CRT) do not derive any clinical benefit. CRT response can be improved by tailoring LV lead placement and programming of atrio-ventricular (AV) and inter-ventricular (VV) stimulation intervals to the individual patient. However, the best strategy to optimize lead positioning and device programming still remains to be established. Earlier work in our research group suggests that the vector cardiogram (VCG) can be used to determine the optimal LV lead position and AV- and VV-intervals, and pilot studies showed the feasibility to derive a VCG-like signal (D-VCG) from the implanted pacing electrodes. Other studies have suggested that the best position for the LV electrode is the region of latest electrical activation. The region of latest electrical activation can be identified by measuring the electrical delay on the LV lead (LVLED) during implantation. The objective of this study is to investigate whether D-VCG can be used to determine the optimal AV- and VV-interval and whether VCG and LVLED can be used to determine the optimal LV lead position.


Clinical Trial Description

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure (HF) patients with severe left ventricular (LV) systolic impairment and delayed electrical impulse conduction through the ventricles, such as left bundle-branch block (LBBB). Since initial approval of the therapy over 10 years ago, there have been hundreds of thousands of implants worldwide. In The Netherlands, currently more than 2000 CRT devices are implanted each year. In a heart with LBBB, electrical activation of the lateral LV free wall is delayed, which leads to dyssynchronous and inefficient LV mechanical contraction and compromised LV pump function. The positive impact of CRT on LV pump function is attributed to paced pre-excitation of the delayed activated lateral LV wall. CRT is most commonly applied by pacing the right ventricle (RV) and LV lateral wall (almost) simultaneously. This corrects the abnormal LV electrical activation and resynchronizes LV mechanical contraction, which in turn results in improved LV pump function.

Despite the striking effectiveness of CRT, 30-50% of apparently suitable patients show little or no improvement. Previous studies have shown that the response to CRT can be improved by tailoring LV lead placement and programming of atrioventricular (AV) and inter-ventricular (VV) stimulation intervals to the individual patient. In clinical practice, echocardiographic techniques are the most widely employed for CRT optimization. However these techniques are subject to large measurement errors and inter- and intra-observer variability. A more accurate technique is invasive assessment of acute hemodynamic response to CRT, with the most widely used invasive hemodynamic parameter being the maximum rate of LV systolic pressure rise (LVdP/dtmax). However, the invasive and time-consuming nature of this approach limits its use in clinical practice. Thus, the best strategy to optimize lead positioning and device programming still remains to be established.

Earlier work in our research group suggests that the vectorcardiogram (VCG) can be used to determine the optimal LV lead position and AV- and VV-intervals, and pilot studies showed the feasibility to derive a VCG-like signal (D-VCG) from the implanted pacing electrodes. Other studies have suggested that the best position for the LV electrode is the region of latest electrical activation. The region of latest electrical activation can be identified by measuring the electrical delay on the LV lead (LVLED) during implantation. Validation of these techniques for tailoring LV lead positioning and AV- and VV- stimulation intervals to the individual patient, will provide non-invasive and easy methods to optimize CRT application and improve response rate.

The objective of this study is to investigate whether D-VCG can be used to determine the optimal AV- and VV-interval and whether VCG and LVLED can be used to determine the optimal LV lead position. Validation of these techniques for tailoring LV lead positioning and AV- and VV- stimulation intervals to the individual patient, will provide non-invasive and easy methods to optimize CRT application and improve response rate. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02326493
Study type Interventional
Source Maastricht University Medical Center
Contact
Status Completed
Phase N/A
Start date November 2014
Completion date November 2016

See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05654272 - Development of CIRC Technologies
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy