Early glaucomatous visual field changes can be missed with the routinely used Standard Automated Perimetry (SAP) and the 24-2 test pattern due to limited sampling of the central 10 degrees. While this shortcoming can be overcome with the addition of a 10-2 test, performing both tests places extra demand on the perimetric services (doubling test times) and patients. Smart Supra Perimetry (SSP) uses a new faster algorithm that can complete both 24-2 and 10-2 test patterns in a similar time frame to a single 24-2 SAP test. This comparative study aims to determine the sensitivity and specificity (i.e. diagnostic accuracy) of SSP in identifying early glaucomatous visual field loss. A sample of 100 patients with early/suspect glaucoma will undergo SAP 24-2 and 10-2 (SITA algorithm) using Humphrey visual field perimetry and SSP 24+10-2 using Henson 9000. Eyes will be categorised into 2 groups i.e., glaucoma and non-glaucoma, on the basis of structural changes to the disc as evaluated by the clinician. The sensitivity and specificity of the SAP and SSP tests will be established along with test duration. The size and location of defects established with both the SAP and SSP strategies will also be compared.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03978546
Study type Interventional
Source Manchester University NHS Foundation Trust
Contact
Status Completed
Phase N/A
Start date June 11, 2019
Completion date March 31, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02520674 - Glaucoma Screening With Smartphone Ophthalmology N/A