Glaucoma Clinical Trial
Official title:
Diagnostic Performance of Smart Supra Perimetry (SSP) in Comparison With Standard Automated Perimetry (SAP) and Ocular Coherence Tomography (OCT).
Early glaucomatous visual field changes can be missed with the routinely used Standard Automated Perimetry (SAP) and the 24-2 test pattern due to limited sampling of the central 10 degrees. While this shortcoming can be overcome with the addition of a 10-2 test, performing both tests places extra demand on the perimetric services (doubling test times) and patients. Smart Supra Perimetry (SSP) uses a new faster algorithm that can complete both 24-2 and 10-2 test patterns in a similar time frame to a single 24-2 SAP test. This comparative study aims to determine the sensitivity and specificity (i.e. diagnostic accuracy) of SSP in identifying early glaucomatous visual field loss. A sample of 100 patients with early/suspect glaucoma will undergo SAP 24-2 and 10-2 (SITA algorithm) using Humphrey visual field perimetry and SSP 24+10-2 using Henson 9000. Eyes will be categorised into 2 groups i.e., glaucoma and non-glaucoma, on the basis of structural changes to the disc as evaluated by the clinician. The sensitivity and specificity of the SAP and SSP tests will be established along with test duration. The size and location of defects established with both the SAP and SSP strategies will also be compared.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06000865 -
Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE
|
N/A | |
Recruiting |
NCT06278597 -
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03274024 -
The Asia Primary Tube Versus Trab (TVT) Study
|
N/A | |
Completed |
NCT04552964 -
Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma
|
N/A | |
Recruiting |
NCT01957267 -
Functional and Structural Imaging for Glaucoma
|
||
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Completed |
NCT04020705 -
The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma
|
N/A | |
Completed |
NCT03150160 -
Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma
|
Phase 4 | |
Not yet recruiting |
NCT05581498 -
Glaucoma Exercise as Medicine Study (GEMS).
|
N/A | |
Recruiting |
NCT02921568 -
Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes
|
N/A | |
Active, not recruiting |
NCT02901730 -
Clinical Study of LPI With Different Laser Wavelengths
|
N/A | |
Completed |
NCT02955849 -
A Trial of China Laser and Surgery Study Glaucoma in Rural China
|
Early Phase 1 | |
Recruiting |
NCT02554214 -
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
|
N/A | |
Recruiting |
NCT02471105 -
Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml
|
Phase 4 | |
Active, not recruiting |
NCT02390284 -
Stop Retinal Ganglion Cell Dysfunction Study
|
Phase 3 | |
Completed |
NCT02390245 -
Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study
|
N/A | |
Completed |
NCT02246764 -
Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension
|
Phase 3 | |
Completed |
NCT02628223 -
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
|
N/A | |
Completed |
NCT02520674 -
Glaucoma Screening With Smartphone Ophthalmology
|
N/A |