Clinical Trials Logo

Fractures, Compression clinical trials

View clinical trials related to Fractures, Compression.

Filter by:

NCT ID: NCT02085811 Recruiting - Thoracolumbar Spine Clinical Trials

Screening for Kyphosis in the Mean Term in Patients Treated With Kyphoplasty Alone in the Management of Stable Traumatic Compression Fractures of the Thoracolumbar Spine

KIPHO
Start date: June 2013
Phase: N/A
Study type: Observational

The aim of this retrospective study is to show that kyphoplasty is a reliable technique in the treatment of certain traumatic vertebral fractures. Patients will be selected from medical records archived at the Neuroradiology Department of Dijon CHU. An information sheet and questionnaire will be sent to patients together with a letter to ask them to have a radiographic examination. The radiographic images will be interpreted by two independent experts to evaluate the angle pf vertebral kyphosis.

NCT ID: NCT02049931 Completed - Clinical trials for Compression Fracture

Comparison of Treatments of Osteoporotic Compression Fracture Using Rigid Brace, Soft Brace, and no Brace

Start date: December 2012
Phase: N/A
Study type: Interventional

The treatment outcomes in the treatment without brace would be non-inferior to those in use of rigid or soft brace.

NCT ID: NCT01913587 Completed - Clinical trials for Spinal Compression Fracture

Efficacy Study of Acupuncture on Spinal Compression Fracture

Start date: March 2013
Phase: N/A
Study type: Interventional

This study is to investigate the effectiveness of acupuncture for alleviating pain from Spinal Compression Fracture in Patients Treated with Nerve Block.

NCT ID: NCT01871519 Completed - Cancer Clinical Trials

Evaluation of Outcomes for Quality of Life and Activities of Daily Living for BKP in the Treatment of VCFs

EVOLVE
Start date: May 2013
Phase: N/A
Study type: Interventional

The study objective is to collect and report 12-month outcomes pertaining to activities of daily living, quality of life, and safety parameters in a Medicare population to be treated with balloon kyphoplasty in the treatment of painful, acute, vertebral body compression fractures (VCFs) associated with either osteoporosis or cancer. The primary objective is to show statistically significant improvement from baseline in the four co-primary endpoints (SF-36v2, PCS, EQ-5D, NRS back pain and ODI) at 3-months; study success will be declared if the primary objective is met. New radiographic fractures, non-surgical management received, VCF-related healthcare resource utilization, and vertebral body height restoration data will also be collected.

NCT ID: NCT01839682 Completed - Osteoporosis Clinical Trials

Evaluation of Outcomes of DFine StabiliT Kyphoplasty in Vertebral Compression Fractures Due to Osteoporosis

Start date: June 2009
Phase: N/A
Study type: Observational

This post-market surveillance research project consists of data collection at specified time points using standard questionnaire instruments to compare pain level, mobility and function pre and post procedure using the D-Fine StabiliT® Vertebral Augmentation System and StabiliT® Bone Cement, an FDA approved product used in the standard treatment of vertebral compression fractures.

NCT ID: NCT01643395 Completed - Clinical trials for Vertebral Compression Fracture

VertebrOpLasty Versus Conservative Treatment in Acute Non Osteoporotic Vertebral Fractures

VOLCANO
Start date: September 2010
Phase: Phase 3
Study type: Interventional

The purpose of this protocol is to prove the efficacy of vertebroplasty in patients suffering from acute non osteoporotic vertebral compression fracture. Vertebroplasty consists in the injection of cement (PMMA) in the damaged vertebral body to prevent further collapse. Our study will compare vertebroplasty versus conservative therapy (brace).

NCT ID: NCT01609712 Recruiting - Lung Function Clinical Trials

Osteoporotic Vertebral Compression Fractures: Can Kyphoplasty Improve Lung Function? A Prospective Evaluation

Start date: May 2012
Phase: N/A
Study type: Observational

Patients with vertebral fractures often have problems to straighten and as a consequence of impaired lung ventilation that leads to a impaired lung function. Furthermore, it comes to the sintering of the vertebra and a so-called hunchback. This also contributes to the poorer expansion of the lung. Pain is also caused by respiratory excursions of the chest which hinder the patients to use their entire lung volume. Kyphoplasty is designed to counter all these consequences of vertebral fractures by bringing stability to the fracture. In order to prove the thesis the results of lung function test (FEV1, PEF) are assessed.

NCT ID: NCT01482793 Completed - Clinical trials for Vertebral Compression Fractures

A Controlled Trial of Vertebroplasty for Acute Painful Osteoporotic Fractures

Start date: November 2011
Phase: N/A
Study type: Interventional

The objective of this study is to gather data regarding the efficacy, safety and cost-effectiveness of percutaneous vertebroplasty in the acute fracture group with fractures less than 6 weeks old. The AVAMAX vertebroplasty kits (Care Fusion) will be used for all vertebroplasties. The primary effectiveness analysis will be based on the number of patients whose numeric rating pain score drops from above 7 out of 10 at baseline to below 4 out of 10 at two weeks post-intervention. Our hypothesis is that the vertebroplasty group will have a significantly larger proportion of patients achieving pain reduction than the control group. A secondary analysis will compare the change in mean pain scores and specific activity related pain scores between the two groups at 3 days, 14 days and at 1, 3 and 6 months. Another secondary effectiveness analysis will include the mean change in the back-pain specific limitation in function as quantified by the Roland Scale at these same data collection time points.

NCT ID: NCT01480167 Withdrawn - Clinical trials for Painful Osteoporotic Vertebral Compression Fractures (VCF)

The PRIORi-T Trial--Prospective Randomized Investigation of Radiofrequency Targeted Vertebral Augmentation

PRIORi-T
Start date: November 2011
Phase: Phase 4
Study type: Interventional

The objective of this post market clinical investigation is to evaluate the clinical effectiveness of a minimally invasive vertebral augmentation procedure, Radiofrequency-Targeted Vertebral Augmentation (RF-TVA) as compared to non-operative management (NOM) for the treatment of appropriately diagnosed acute (≤ 8 weeks) painful osteoporotic vertebral compression fractures (VCF).

NCT ID: NCT01410929 Withdrawn - Multiple Myeloma Clinical Trials

Evaluation of Vertebral Compression Fracture Fixation With RF Kyphoplasty in Patients With Multiple Myeloma

MM
Start date: May 2011
Phase: Phase 4
Study type: Interventional

The objective of this post market clinical study is to collect prospective clinical data to confirm the efficacy of RF Kyphoplasty for the treatment of pathological fractures of the spine caused by multiple myeloma.