Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to determine if restoring normal metabolic function in patients with either type I or type II diabetes can improve the impact of the consequences of diabetic complications on the overall quality of life of diabetic patients. Patients are treated once a week with pulsatile intravenous insulin therapy mimicking normal insulin secretion. A 44 item questionnaire is completed prior to the start of the treatment and quarterly thereafter with detailed analysis performed to measure progress and outcomes.


Clinical Trial Description

It is known that the glucose metabolic pathway (glycolysis) is the primary fuel generator in the brain and nerve tissue, the heart and vascular tissue, the eye, the kidney and the liver Deficient metabolic states such as seen in the glucose metabolism of diabetics can lead to sequelae. These damaging effects are exacerbated by altered cellular metabolites, specifically the increase in catabolic and decrease in anabolic factors. It has been shown over the past twenty years that normalization of metabolism in diabetic patients can be accomplished by mimicking the normal endogenous insulin pattern (ie., in pulses). Pulsatile insulin infusion has been demonstrated to reverse the diabetic metabolic state from primary fat utilization to carbohydrate utilization. This has been correlated with a stabilization of kidney function in patients with overt diabetic nephropathy, stabilization of blood glucoses, stabilization of blood pressure patterns, and reversal of hypoglycemic unawareness.

The Diabetes Impact Measurement Scale was originally developed to assess quality of life in patients with types 1 and 2 Diabetes Mellitus. This study measures whether the reversal of abnormal metabolism in patients with diabetes is correlated with an improvement in their quality of life.The respiratory quotient (RQ) is a measurement of CO2 exhaled and O2 inhaled and is proportionate to the fuel sources being used by the body, primarily the liver over short periods of time. The higher the RQ, the more glucose and less alternative fuel sources are being utilized. Following the RQ change helps determine the effectiveness of physiological insulin administration in increasing anabolic functions in diabetic individuals. By improving the body's glucose metabolism and thereby causing beneficial effects of anabolic factors, the possibility of serious complications can be decreased. In addition the use of oral carbohydrate at the same time along with the physiologic insulin administration stimulates the appropriate gut hormones which augment this effect, a response which cannot be duplicated with intravenous glucose. The purpose of our studies is to determine whether the physiologic administration of insulin along with the augmenting effect of oral carbohydrates will normalize metabolism in diabetic patients and improve their quality of life indices.

The RQ is determined by the use of a metabolic cart. Individuals breathe into a mask for 3-5 minutes after a rest period of 30 or more minutes. The ratio of exhaled volume of CO2 to the inhaled volume of O2 is determined as the RQ. The physiologic range is 0.7 to1.3. Individuals using fat as a primary fuel have a ratio of 0.7, protein or mixed fuels is 0.8-0.9 and carbohydrate is 0.9-1.0. Those taking excessive calories will have RQ's higher than 1.05. The RQ can be followed serially and this is done before and after each pulsatile IV insulin treatment, during the 3 successive sessions on a single treatment day. The amount of intravenous insulin and oral glucose given is determined by the RQ changes during the previous session.pulsatile IV insulin therapy encourages the glucose metabolism in diabetics to normalize in multiple organs, especially muscle, retina, liver, kidney and nerve endings. The process fundamentally requires the administration of high dose insulin pulses similar to those found in non diabetic humans by their pancreas into the surrounding portal circulation. Oral carbohydrates are given simultaneously to augment the process and prevent hypoglycemia. The process is monitored by frequent glucose levels and respiratory quotients (RQ). RQ is measured by a metabolic cart which determines the ratio VCO2/ VO2. This ratio is specific for the fuel used at any one time by the body. The glucose levels are monitored to keep glucose levels appropriate and the RQ determines the need to readjust the infusion protocol in each patient for subsequent insulin infusion sessions.Patient is evaluated post session and discharged when stable.

Frequent monitoring of RQ is necessary as these levels change rapidly, depending on the fuel being utilized by the body. Pulsatile IV insulin therapy shifts metabolism from primarily fatty acid metabolism to primarily glucose metabolism. This shift is reflected by the increase in respiratory quotient. However during rest periods the RQ may fall back to lower levels. Therefore RQ's are done at the beginning and at the end of each insulin infusion session of 1 hour in order to appropriately monitor and adjust insulin and carbohydrate loads to reach optimal activation in each session. ;


Study Design

Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00228878
Study type Interventional
Source Florida Atlantic University
Contact
Status Terminated
Phase Phase 2/Phase 3
Start date March 2003
Completion date August 2009

See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A