Clinical Trials Logo

Clinical Trial Summary

The standard method for determining the carbohydrate content of a meal in patients with diabetes mellitus is the weighing of individual foods. However, in daily life, the weighing is not practical at all times. Inaccurate estimation of meal's CHO content, leads to wrong insulin doses and consequently to poor postprandial glucose control. Fact is that even well trained diabetic individuals find it difficult to estimate CHO precisely and that especially meals served on a plate are prone to false estimations underlining an emergent need for novel approaches to CHO estimation.

GoCarb is a computer vision-based system for calculating the carbohydrate content of meals. In a typical scenario, the user places a credit card-sized reference object next to the meal and acquires two images using his/her smartphone. A series of computer vision modules follows: the plate is detected and the different food items on the plate are automatically segmented and recognized, while their 3D shape is reconstructed. On the basis of the shape, the segmentation results and the reference card, the volume of each item is then estimated. The CHO content is calculated by combining the food types with its volumes, and by using the USDA nutritional database. Finally, the results are displayed to the user.

A preclinical study using the GoCarb system indicates that the system is able to estimate the meal's CHO content with higher accuracy than individuals with T1D. Furthermore, the feedback gathered by the participants showed that the system is easy to use even for non-smartphone users.

The aim of this randomized, cross-over pilot study is to investigate the benefits of an automated determination of the carbohydrate content of meals on glycemic control in subjects with type 1 diabetes mellitus with sensor-augmented insulin pump therapy.


Clinical Trial Description

Background

For individuals with type 1 diabetes (T1D) the current gold standard to evaluate the carbohydrate (CHO) amount of a meal is by carefully weighing its different components and calculating the CHO content using reference nutritional tables. The resulting CHO amount is then used to define the insulin dose needed to avoid an abnormal postprandial glucose profile. Since this is a cumbersome procedure in real life, diabetic individuals often estimate the CHO amount based on their personal experience. Especially for food served on a plate CHO estimates are often significantly over or underestimated leading to high variation in postprandial blood glucose. Besides the immediate risk of hypoglycaemia, there is emerging evidence that suboptimal control of postprandial glucose is affiliated with increased risk for long-term complications (e.g. diabetic micro- and macro-vascular diseases).

The effect of CHO counting in T1D control has been increasingly recognized and investigated. A meta-analysis including five studies on individuals with T1D has shown, that improved CHO counting accuracy reduces the HbA1c significantly (0.64% reduction in HbA1c compared to a control group). Teaching adult individuals with T1D to count CHO reduces HbA1c significantly and also leads to an improvement in quality of life. Similar findings are reported in children, in whom higher CHO counting accuracy is associated with a lower HbA1c. Even a short educational intervention of 4 weeks can still result in a significant and sustained effect on HbA1c reduction 9 months after without having an increase in hypoglycaemia. Lower CHO counting accuracy is a significant predictor of prolonged time in hyperglycaemic state. In one study with adults only 31% of the participants estimated the CHO content with an error of less than 20 grams per day and accurate CHO estimation were correlated with the lowest HbA1c values. In line with these findings another study has shown that individuals on intensive insulin therapy count CHO content of meals with an average error in the order of 16 grams or 21%. In general there is overestimation of small meals and a substantial underestimation of large meals. While breakfast (+8.5%) and snacks (-5%) were estimated fairly accurately, lunch (-28%) and dinner (-23%) are more prone to errors leading to an underestimation in the order of 30 grams. In children, an inaccuracy of ±10grams does not deteriorate the postprandial glycaemic control, whereas a ±20 grams variation significantly impacts the postprandial glycaemia.

The debate how to optimally estimate CHO intake is on-going and controversial. Fact is that even well trained diabetic individuals find it difficult to estimate CHO precisely and that especially meals served on a plate are prone to false estimations underlining an emergent need for novel approaches to CHO estimation. The investigators hypothesize that computer vision supported CHO estimation can have a beneficial impact on postprandial glucose control, ultimately leading to reduced episodes of hypoglycaemia and reduction in long term complications.

The recent advances in smartphone technologies and computer vision permitted the development of applications for the automatic dietary assessment through meal image analysis. The applications are using either a number of images or a short video of the upcoming meal, as captured by the user's smartphone. Although several systems have been proposed in the past decade, none of them is designed for individuals with diabetes, while they rely on strong assumptions, which often do not hold in real life, or require too much user input. The GoCARB system provides CHO estimations to individuals with T1D, by using only two meal images. The current version GoCARB has been designed to deal with

- elliptical plates with a flat base;

- single-dish images;

- fully visible food items. The system works without assumptions on the food shape, while it supports the following food classes: Pasta, green salad, meat, breaded food, beans, carrots, mashed potato, rice, potatoes, bread, cheese, egg, couscous, mushrooms and spätzli.

Objective

The purpose of this study is to investigate the effect of GoCARB-supported CHO estimation in the postprandial glucose control of individuals with T1D on sensor augmented insulin pump therapy.

In a typical scenario, the user places a credit card-sized reference object next to the meal and acquires two images using her/his smartphone. A graphical user interface guides the user in choosing the optimal angles for image acquisition based on the smartphone's built-in sensors. The images are then transmitted to a dedicated server via Wi-Fi or the mobile network. Then, the following computer vision algorithms are activated: the plate is detected and the different food items on the plate are automatically segmented and recognized, while their 3D shape is reconstructed. On the basis of the shape, the segmentation results and the reference card, the volume and CHO content of each item is then calculated by combining the food types with its volumes. Finally, the results are displayed to the user.

Methods

This study's overall objective is to perform a prospective randomized controlled clinical pilot study comparing postprandial glucose control assisted by the GoCARB system against the usual care approach by the participants. Scope of the study will be to investigate whether the postprandial glucose profile is improved by using the GoCARB prototype for CHO estimation. Postprandial glycaemia is evaluated using continuous glucose monitoring. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Open Label


Related Conditions & MeSH terms


NCT number NCT02546063
Study type Interventional
Source University Hospital Inselspital, Berne
Contact
Status Completed
Phase N/A
Start date August 2015
Completion date December 2015

See also
  Status Clinical Trial Phase
Completed NCT04030091 - Pulsatile Insulin Infusion Therapy in Patients With Type 1 and Type 2 Diabetes Mellitus Phase 4
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT01696266 - An International Survey on Hypoglycaemia Among Insulin-treated Patients With Diabetes
Recruiting NCT06050642 - Study of the Impact of PROximity Support for Patients With Type 1 DIABetes Treated With an Insulin Pump or Closed Loop. N/A
Completed NCT05107544 - Metabolic, Physical Fitness and Mental Health Effects of High Intensity Interval Training (HIIT) in Adolescents With Type 1 Diabetes N/A
Recruiting NCT04443153 - Adapting Diabetes Treatment Expert Systems to Patient in Type 1 Diabetes N/A
Completed NCT04521634 - Glycaemic Variability in Acute Stroke
Completed NCT04569994 - A Study to Look at the Safety of NNC0363-0845 in Healthy People and People With Type 1 Diabetes Phase 1
Completed NCT04089462 - Effects of Frequency and Duration of Exercise in People With Type 1 Diabetes A Randomized Crossover Study N/A
Completed NCT03143816 - Study Comparing Prandial Insulin Aspart vs. Technosphere Insulin in Patients With Type 1 Diabetes on Multiple Daily Injections: Investigator-Initiated A Real-life Pilot Study-STAT Study Phase 4
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A
Completed NCT04042207 - Diabeloop for Highly Unstable Type 1 Diabetes N/A
Not yet recruiting NCT06068205 - COMPARATIVE ANALYSIS OF THE MORPHO-MECHANICAL PROPERTIES OF RED BLOOD CELLS EXTRACTED FROM DIABETIC PATIENTS WITH AND WITHOUT MICROVASCULAR COMPLICATIONS
Recruiting NCT05909800 - Prolonged Remission Induced by Phenofibrate in Children Newly Diagnosed With Type 1 Diabetes. Phase 2
Active, not recruiting NCT04974528 - Afrezza® INHALE-1 Study in Pediatrics Phase 3
Completed NCT04530292 - Home Intervention and Social Precariousness in Childhood Diabetes N/A
Completed NCT05428943 - OPT101 in Type 1 Diabetes Patients Phase 1
Recruiting NCT03988764 - Monogenic Diabetes Misdiagnosed as Type 1
Completed NCT05597605 - The SHINE Study: Safety of Implant and Preliminary Performance of the SHINE SYSTEM in Diabetic Subjects N/A