Clinical Trials Logo

Clinical Trial Summary

Using the traditional and hitherto used uncemented hip prostheses achieved good clinical results, but one of the drawbacks is the risk of fracture in the femoral shaft in indbankning of the prosthesis (1-2%). In addition, the bone scan demonstrated that in the years after surgery dropped almost 30% of bone mass in the femoral shaft. This bone loss increases the risk that in the years after surgery, the increased risk of fractures around the prosthesis and in addition to impeding the described bone replacement prosthesis later. The newly developed prosthesis is anchored in the femoral neck and thus not involve the femoral shaft. This ensures a more physiological or normal weight transfer to the femur bone. This contributes to bone mass in long large extent preserved in the years after surgery, so you have a better opportunity later to make a new prosthesis surgery with good results. The new prosthesis should be capable of simultaneously reducing the incidence of thigh pain in the first year after surgery.'


Clinical Trial Description

By insertion of artificial hip joints in young and middle aged are often used so-called uncemented technique in which the prosthesis is fixed to the bone without the use of bone cement. Anchoring happens when the bone cells grow into the prosthesis porous surface, thereby creating a stable anchorage of the prosthesis, both short and long term. A hip prosthesis consists of 3 main elements: 1. socket 2. ball 3. femoral component, which hold ball. Femoral component is anchored to the upper end of the femur including the upper 12-15 cm of the marrow cavity. Achieved good results with this principle. The method involves a risk of fracture at the top end of the femur bone during and after insertion of the prosthesis, but also that there is some bone loss in the year after surgery. Finally there is a 3-10% chance that you get thigh pain due to different elasticity of the femur and the long shank prosthesis. Based on the foregoing disadvantages of the femoral components, which are commonly used, has for years been experimenting with the introduction of shorter implants, which are either anchored in the femoral neck or femoral neck combined with the very top end of the femur bone (metaphysis). By using such a prosthesis, it is proven to preserve the bone in the upper femur forward and avoids the disadvantage in terms of the above described femoral pain. There is also described problems by using these short prostheses, especially in the form of solution, and pain secondary to anchor bolts in the upper femur forward. In Orthopaedic Surgery, Region Nordjylland, one has in the period 1999 to 2003 33 such prostheses implanted at clinics in Farsø and Frederikshavn and achieved good results apart from pain similar to the above anchoring screws. At follow-up of these prostheses, using DEXA scans, the investigators have shown that prosthesis, bone-saving, since bone mass at the femoral neck and the very top end of the femur bone is preserved. From our experience with the aforementioned short prosthesis, the investigators have joined with Biomechanical Institute, Royal National Orthopaedic Hospital, Stanmore, London and firm Biomet developed a modern design of the above. This is a short prosthesis that is anchored in the femoral neck and the upper end of the femur (metaphysis). Prosthesis made of titanium with a porous surface (Bonemaster ®). The prosthesis is anchored during surgery by pressure-fit (press-fit) and in a few weeks the bone grows into the prosthesis. Prosthesis manufactured in 5 sizes and design of the prosthesis is aligned with a series of CT scans of the femur was carried out at Stanmore in London. Has developed instruments to ensure a uniform instrumentation and minimizing the risk of fractures in connection with the operation. Performed a series of laboratory tests and these tests, the prosthesis was found to be completely stable and even full load stable and the risk of fracture related to prosthesis insertion is minimized. The current study intends to examine whether that can be achieved equally good clinical results as with the conventional uncemented femoral component and bone mass in the upper end of the femur bone is preserved. Using a specific X-ray analysis (RSA) also assessed the stability between the prosthesis and bone. Both DEXA scan as RSA studies have routine examinations by Orthopaedic Surgery, Region Nordjylland, Klinik Farsø. The planned surgery 50 young men and women with primary or secondary osteoarthritis of the hip joint. Patients fulfilling the inclusion criteria and not subject to exclusion criteria received oral and written information about the investigation. Accept the patient to cooperate with the investigation confirmed that the patient's signature approx. 2 weeks after oral and written information is given. The operation is performed after the usual principles with rear access to the hip joint, removal of rod ends and the insertion of an uncemented socket. After preparing the femoral neck and top of thigh to the insertion of the short femur prosthesis and make selection using tantalumkugler for RSA analysis. When the prosthesis is inserted carried out sample-space theorem and using a 36 mm Co-Cr-ball, which is currently the department's practices. After surgery the patient allowed partial load the first 6 weeks. There is an ongoing clinical and radiographic controls and registration of unforeseen events arising from the use of the product. If the flow after 2 years are fully comparable clinical outcomes, minimal migration as measured by RSA and final preservation of the bone around the implant, then the use of the implant extends to several clinics at home and abroad, as per the recommendations of the Danish Orthopaedic Association reference program for hip replacement surgery. When implementing any new implant designs is a lower risk of unforeseen complications in the form of fracture encountered in denture-deployment and subsequent unexpected prosthetic solution. If the burst occurs Intraoperative, you can convert to the deployment of conventional hip prosthesis without involving major risks for the patient. Early prosthetic solution is also possible deployment of conventional complete dentures without result deteriorates. The disadvantages of the possible complications are in the worst case of operation (revision). In addition, the disadvantages of trial participation increased radiation dose due to 4 additional X-ray checks in the first 2 years after surgery and 4 extra bone scans (DEXA). The described investigation will clarify whether the theoretical advantages that have hitherto been demonstrated by clinical and biomechanical study (normal weight transfer, bone sparing and bone-keeping in the short and long term), also obtained by applying the newly developed prosthetic component. If so, there will then be able to especially younger patients with osteoarthritis of the hip joints better chance of achieving good clinical outcomes and long-term sustainability by eventual replacement surgery, typically 10-20 years after primary surgery. Disadvantages of the described study estimated minimal compared to the benefits that a large group of patients could benefit. The actual cost of conducting the survey shall be borne by the prosthesis manufacturer Biomet UK Ltd.. and Orthopaedic Surgery, North Jutland and the amount transferred to specific research account affiliated research unit of Orthopaedic Surgery, Region Nordjylland and paid through the Budget and Finance, Region House, Region Nordjylland. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01326832
Study type Observational
Source Zimmer Biomet
Contact
Status Active, not recruiting
Phase
Start date September 2011
Completion date December 2024

See also
  Status Clinical Trial Phase
Completed NCT02399670 - The Influence of Global Femoral-offset Changes After Total Hip Arthroplasty N/A
Completed NCT01046019 - Measurement of Early Bone Loss Around a Total Hip Arthroplasty N/A
Completed NCT00159497 - Bone Remodeling Around HA-coated Acetabular Cups. Phase 4
Not yet recruiting NCT04570748 - Effect of Capsular Repair on the Outcomes of Direct Anterior Total Hip Arthroplasty. N/A
Not yet recruiting NCT01079455 - Comparison of Hyaluronic Acid and Corticosteroid Intra-articular Injections for the Treatment of Osteoarthritis of the Hip Phase 3
Completed NCT00317889 - Compaction Total Hip Arthroplasty (THA) Bilateral N/A
Recruiting NCT04424628 - Radiotherapy 3 vs 6 Gy in Gonarthrosis and Coxarthrosis N/A
Not yet recruiting NCT06272422 - Comparison of the Restoration of Hip Biomechanical Parameters by CT Measurement Between the 3 Surgical Techniques: RSA/Minihip/THA - Hip Replacement: 3D Planning
Completed NCT02694146 - Clinical Trial to Evaluate the Use of Platelet Rich Plasma in Front Hyaluronic Acid in Coxarthrosis Phase 3
Completed NCT02719236 - Direct Anterior Approach Versus Direct Lateral Approach in Total Hip Arthroplasty N/A
Completed NCT05343195 - Balance and Leg Function After Hip Replacement N/A
Completed NCT01279174 - Galileo-Hip Whole Body Vibration /Conventional Physiotherapy /Coxarthrosis Phase 4
Active, not recruiting NCT00318396 - Compaction Femur Preparation for Cementless Total Hip Arthroplasty (THA) Unilateral N/A
Completed NCT02338596 - Ultra-Short Anatomic and Conventional Cementless Stems Cementless Stems in Patients Younger Than Fifty-Five Years Old Phase 4
Active, not recruiting NCT00722982 - Migration Pattern of C-stem AMT Versus Exeter in Total Hip Arthroplasty N/A
Completed NCT04903860 - Comparison of the Use of Conventional Ancillary Reaming and Single-use Ancillary Reaming Material in Total Hip Replacement N/A
Recruiting NCT04317872 - Effect of Peri-operative Glucocorticoids on Short-term Functional Outcome After THA N/A
Recruiting NCT03809962 - Efficacy and Safety of Ostenil® Plus in the Treatment of Coxarthrosis
Active, not recruiting NCT01578746 - Comparison Between Anterior and Direct Lateral Approach in Total Hip Arthroplasty Phase 4
Completed NCT00317863 - Zink and Bone Strength N/A