Clinical Trials Logo

Clinical Trial Summary

During percutaneous cardiovascular intervention, temporary cardiac stimulation may be required. Usually this stimulation is generated via a temporary pacing catheter. In order to reduce the complexity of the procedure, a new stimulation strategy has been developed: the "Direct Wire Pacing technique".In this approach, the cardiac stimulation is provided via the guidewire connected to an external pacemaker. Previous study demonstrated the superiority of the new technique compared to the former. However this technique is likely to generate electrical pain, risk of bleeding for the patient and risk of blood exposure accident for the operators. This is why the medical device ELECTRODUCER SLEEVE has been developed. This device integrates a pacing function to the introducer and the guidewire used. The "Direct Wire Pacing technique" is simplified, secured and more reproducible.


Clinical Trial Description

During percutaneous cardiovascular interventions such as Transcatheter Heart Valve or coronary intervention, temporary cardiac stimulation may be required. Usually this stimulation is generated via a temporary pacing catheter in the right ventricle. This procedure requires an additional venous access and the insertion of the stimulation catheter, which are both likely to generate complications. In order to reduce the complexity and increase the safety of the procedure, a new stimulation strategy has been developed: the "Direct Wire Pacing technique". In this approach, the specific venous access and the implantation of a stimulation catheter are avoided. The cardiac stimulation is provided via the guidewire inserted into the left ventricle or into the coronary arteries. This guidewire is connected to an external Pacemaker using an alligator clamp (Cathode). The Pacemaker anode is also connected using a clamp attached to a needle piercing the subcutaneous tissue, obtaining a closed electrical circuit. This technique was validated during previous studies in the TAVI context through two registries and one randomized controlled trial. This study demonstrated the superiority of the new technique by showing a reduction of the procedural duration, radiation exposure and costs; with similar efficacy and safety. However the subcutaneous needle insertion is likely to generate electrical pain, risk of bleeding for the patient and risk of blood exposure accident for the operators. This subcutaneous anode increases the stimulation threshold (mA) which can cause stimulation failures. Moreover, several technical difficulties preclude general adoption by the scientific community. This is why the medical device ELECTRODUCER SLEEVE has been developed. This device integrates a pacing function to the introducer and the guidewire used during percutaneous cardiovascular interventions. The guidewire then behaves like an intra-cardiac cathode. Thanks to the device, the complex manipulation of needles and clamps during the intervention are avoided as well as pole inversions. The "Direct Wire Pacing technique" used during the coronary and structural interventions is thus simplified, secured and more reproducible. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04372654
Study type Interventional
Source Electroducer
Contact
Status Completed
Phase N/A
Start date July 28, 2020
Completion date February 22, 2021

See also
  Status Clinical Trial Phase
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Completed NCT05672862 - International Post-PCI FFR Extended Registry
Completed NCT04492423 - VerifyNow® PRUTest® Cardiovascular Population Expected Values On-Drug Study
Completed NCT01205776 - EXCEL Clinical Trial N/A
Recruiting NCT01218776 - International Survey of Acute Coronary Syndromes in Transitional Countries
Completed NCT00046410 - Comparison of the Risk of Stroke With On- Versus Off-Pump Coronary Artery Bypass Grafting N/A
Recruiting NCT04390672 - Multivessel TALENT N/A
Completed NCT02784873 - High Intensity Interval Training in UK Cardiac Rehabilitation Programmes N/A
Completed NCT02948517 - Time Restricted Feeding for Weight Loss and Cardio-protection N/A
Not yet recruiting NCT02895009 - Hemostatic Compression Patterns After Transradial Coronary Intervention N/A
Recruiting NCT02859480 - Dose-dependent Effect of Rosuvastatin on Long-term Clinical Outcomes After PCI Phase 4
Withdrawn NCT02418143 - A Study to Obtain Additional Information on the Use of CorMatrix® CanGaroo ECM® Envelope
Completed NCT02382731 - Interventions to Support Long-Term Adherence aNd Decrease Cardiovascular Events Post-Myocardial Infarction N/A
Completed NCT02510547 - Comparison of a CrossBoss First Versus Standard Wire Escalation Strategy for Crossing Coronary Chronic Total Occlusion: the "CrossBoss First" Trial Phase 4
Recruiting NCT01681381 - Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization N/A
Completed NCT02248415 - Administration of Warm Blood Cardioplegia With or Without Roller Pump N/A
Recruiting NCT01207167 - Mediators of Atherosclerosis in South Asians Living in America
Completed NCT02088138 - Functional Electrical Stimulation in Cardiac Patients N/A
Completed NCT02173067 - Anesthesia With Epinephrine in Diabetes Patients is Safe and Effective N/A
Completed NCT02133807 - Specific Lp(a) Apheresis for Regression of Coronary and Carotid Atherosclerosis Phase 3